background image

EN

next

SYSTEM PROGRAMMING

There are two types of configurations:

1) Using an internal video door when you first start is recommended for 
small building

2) For systems of higher dimensions can be a system configuration from a 

PC by software

To be connected PC to any RJ45 port of InfinitePlay system by patch 

cords.

 

IIP SETUP INSTALLER:

KEY PASSWORD: 000000

Setup by video door phone  

VIDEO DOOR PHONE ID ( ten digit code ):

Building 01

Floor 103

Apartment 050

Internal device 04

PHASES OF CONFIGURATION:

The configuration steps of the system are divided into only 5 points:

1.

BASIC SETTINGS

2.

ENTRANCE PANEL

3.

POWER SUPPLY

4.

VIDEO DOOR PHONE

5.

MAPPING ENTRANCE PANEL

1. BASIC SETTINGS

To be programmed the basic parameters for system

CONCIERGE  ( yes / no )

SOS PANIC BUTTON  ( yes / no )

VIDEO DOOR PHNE VISIBILITY SYSTEM( all video intercom device/ only 

master video intercom device )

SYSTEM SETTING TIME (GMT 00)

SETUP INFINITEPLAY SYSTEM LANGUAGE 

CHANGE PASSWORD OF SYSTEM ( default 000000 )

2. ENTRANCE PANEL

To be programmed all parameters of entrance panel in the system

IDENTIFICATION NUMBER (Mac address out door unit )= B4669800F3

CUSTOM ID NUMBER: from 1 to 200 unit

NAME ENTRACE PANEL: Regent St

SUBTYPE: Choose the subtype of call (1-4 touch buttons, list on LCD 

display, buttons on LCD display ) 

ANSWER TIME (1 to 255 s) 

Default value 30 s

CONVERSATION TIME (1 to 255 s) 

Default value 120 s

SELF-START TIME(1 to 255 s) 

Default value 30 s

AUDIO INDOOR-OUTDOOR (0% to 100%) 

Default value 50%

ENTRANCE PANEL RINGTONE REPETITION ( yes / no )

Default value is yes


SAVE SETTINGS BEFORE YOU GET OUT OF SETUP

BACK 

 

SAVE 

 

Содержание Next Z7000

Страница 1: ...Z7000 Z7100 Installation and operation manual ...

Страница 2: ...ok Description connection terminal block 2 Line video with RJ45 connector PW Input for additional 12V power supply if required PW Mass supplementary feeding FP Connection for door call button with reference to M AL General alarm apartment with reference to M P Panic button user with respect to M M Mass CH1 Relay additional chime CH2 Relay additional chime USB Technical characteristics Semi surface...

Страница 3: ...PROCEDURE 1 SKINNING CABLE 25 30 mm 2 ORDER cable as shown and line up cutting the connectors with scissors at the same height about 10mm 3 INSERT THE CABLE IN CONNECTOR RJ45 as shown in figure 4 CRIMPING WIRE with clamp 5 FINAL CHECK OPERATION with tester Altezza 10mm PIN Code color T568B 1 White orange 2 Orange 3 White green 4 Blue 5 White blue 6 Green 7 White brown 8 Brown ...

Страница 4: ...programmed the basic parameters for system CONCIERGE yes no SOS PANIC BUTTON yes no VIDEO DOOR PHNE VISIBILITY SYSTEM all video intercom device only master video intercom device SYSTEM SETTING TIME GMT 00 SETUP INFINITEPLAY SYSTEM LANGUAGE CHANGE PASSWORD OF SYSTEM default 000000 2 ENTRANCE PANEL To be programmed all parameters of entrance panel in the system IDENTIFICATION NUMBER Mac address out ...

Страница 5: ...ue 1s ENTRANCE PANEL Through entrance panel binds the selected function to one or more entrance panel present in the system To a call from entrance panel will be displayed one priority function LINK This parameter enables indirect opening of the lock at the same time as the opening of the lock of another entrance panel at the command of an interphone monitor interphone Indirect opening can be asso...

Страница 6: ... intercom 1 INTERNAL INTERCOM CALLS Select the list of all internal devices apartment that you can call 2 EXTERNAL INTERCOM CALLS Select the list of the internal intercom of the building that you can call DOCTOR MODE yes no When a call comes in this monitor sends the command lock automatically on power supply AUTO ANSWER yes no By activating this function the indoor unit will enter into conversati...

Страница 7: ...t value 20 suggested STAUTS MESSAGE yes no If you set YES the entrance panel show messages Calling in conversation door lock opened end the conversation ENABLE ANIMATION yes no With this function activates an animation in the outdoor unit display that ease the visitor in the use of the outdoor device SHOW CODE BUTTON yes no Using this function enables the possibility to activate an automation from...

Страница 8: ... symbol choose how long ANSWERING A CALL 1 VIDEO DOOR PHONE FUNCTION 2 TO END THE CALL 3 MUTE MICROPHONE 4 TO ANSWERING A CALL IPCALL VIDEO DOOR PHONE APP 1 VIDEO DOOR PHONE FUNCTION 2 CONCIERCE LIST INTERCOM CONTACT LIST ENTRANCE PANEL LIST LOG ACTIVITIES 3 SETUP AUDIO SETTINGS MESSAGING TO SEND TEXT MESSAGES AND FILES JPG PDF FROM MONITOR TO CONCIERCE AND FROM CONCIERGE TO MONITOR THE COMMUNICAT...

Страница 9: ...e app and choose the name to the contacts list Muting the ringtone during a call Mute function When receiving a call from an outdoor entrance panel or from an intercom device the call ringtone can be muted by pressing button MUTE in home page widget You can set the mute time for example 30 minutes Door lock command If you press the lock button by home page widget to send a lock opening command to ...

Страница 10: ... button S AUX1 AUX2 12Vcc 1A Lock AUX1 Stair light AUX2 Driveway gate Power Supply Z6001 Terminals Up to 100mt 1 2 3 4 5 RJ45 Cable CAT 5 Lock 1 5 mm2 Other 1 mm2 Conductor section RJ45 IN4 free IN1 Lock release IN1 P2 Entrance panel Video door phone AUX3 AUX3 free PORTE RJ45 AL GND N GND GND GND INPUT GND INPUT S Lock return COM 1 COM 2 COM 3 USB IN4 PW PW Power 12V Relè additional chime CH2 USB ...

Страница 11: ...l Video door phone 2 P CH1 FP RJ45 AL PW PW CH2 USB M 2 P CH1 FP RJ45 Panic Button Alarm INPUT GND Outdoor call button AL PW PW Power 12V Relè additional chime CH2 USB M Relè additional chime Power Panic Button Alarm INPUT GND Outdoor call button Power 12V Relè additional chime Relè additional chime Power Mains 90 260Vac 50 60Hz Terminals Up to 100mt 1 2 3 4 5 RJ45 Cable CAT 5 Lock 1 5 mm2 Other 1...

Страница 12: ...ONE 2 VIDEO DOOR PHONES WITH INTERNET CONNECTION AND ONE AUDIO VIDEO ENTRANCE PANEL WITH TWO PUSH BUTTONS HOME INTERNET 12Vcc 1A Lock 1 2 P CH1 FP AL PW PW CH2 USB M 2 P CH1 FP AL PW PW CH2 USB M FIREWALL Distributor Z600F Power Supply Z6001 Terminals Up to 100mt 1 2 3 4 5 RJ45 Cable CAT 5 Lock 1 5 mm2 Other 1 mm2 Conductor section Internet of building ...

Страница 13: ... PHONES 12Vcc 1A Lock CAT5 CAT5 Video door phone 1 2 P CH1 FP AL PW PW CH2 USB M 2 P CH1 FP AL PW PW CH2 USB M Video door phone Video door phone Distributor Z60DV Distributor Z60DV Distributor Z60DV Power Supply Z6001 Video door phone Internet of building Terminals Up to 100mt 1 2 3 4 5 RJ45 Cable CAT 5 Lock 1 5 mm2 Other 1 mm2 Conductor section ...

Страница 14: ...STRIBUTOR CAT5 Video door phone 12Vcc 1A Lock CONCIERGE INTERNET of building Entrance panel 12Vcc 1A Lock 1 1 2 P CH1 FP AL PW PW CH2 USB M Video door phone Distributor Z60DV Distributor Z60DV Power Supply Z6001 Distributor Z60DT Terminals Up to 100mt 1 2 3 4 5 RJ45 Cable CAT 5 Lock 1 5 mm2 Other 1 mm2 Conductor section ...

Страница 15: ... PW PW CH2 USB M 2 P CH1 FP RJ45 AL PW PW CH2 USB M 2 P CH1 FP RJ45 AL PW PW CH2 USB M ALLARM INPUT to concierge Power supply 12 Vdc Video door phone Panic Button Alarm INPUT GND Outdoor call button Power 12V Relè additional chime Relè additional chime Power Panic Button Alarm INPUT GND Outdoor call button Power 12V Relè additional chime Relè additional chime Power Panic Button Alarm INPUT GND Out...

Страница 16: ...e PORTE RJ45 GND N GND GND GND INPUT S Lock return COM 1 COM 2 COM 3 USB IN4 STAIRS LIGHT CONTOL P1 L P3 P4 P5 IN3 IN2 S AUX1 AUX2 12Vcc 1A Lock Power Supply Z6001 IN1 Lock release IN1 P2 AUX3 PORTE RJ45 GND N GND GND GND INPUT S COM 1 COM 2 COM 3 USB IN4 WIRING DIAGRAM DOOR RELESE CONTROL wire 1 5mm2 DOOR RELEASE CONTROL Mains 90 260Vac 50 60Hz Mains 90 260Vac 50 60Hz AUX1 Stair light AUX2 Drivew...

Страница 17: ...17 EN next INSTALLATION NOTE ...

Страница 18: ...18 EN next INSTALLATION NOTE ...

Страница 19: ... framework of the House WARNING This equipment must be fixed to the wall according to the installation instructions This leaflet must always be attached to the system documentation Product is according to EC Directive 2004 108 EC 2006 95 EC and following norms Directive 2012 19 UE WEEE The crossed out wheelie bin symbol marked on the product indicates that the product must be assigned to a differe...

Страница 20: ...Via Monte Grappa 25 31020 Villorba TV ITALY Tel 0422 350680 Fax 0422 446958 www infiniteplay com ENG 18901004 RL00 01 14 ZEALABS ITALY ...

Отзывы: