Infinite Peripherals, Inc.
Page 30
www.ipcprint.com
PP-55 Resident Command Set Version 1.01
Detailed Description
The returned result is four bytes long:
• Byte 1 – <02>H
• Byte 2 – status byte for the current state of the printer
Bit ASB
at:
0 Not
defined
1 Not
defined
2 Overheating
and
cooling of the print head
3
Change in paper state
4
Not defined/
*
Change in the state when searching a
label
5 Not
defined
6
Fixed to ‘1’
7
Change in battery state
*
Available in black mark supporting versions
• Byte 3 – current voltage of the battery plus <20>H
• Byte 4 – current temperature of the print head plus <20>H
[Caution] • ASB function is active only during serial non-protocol (raw)
communication.
• When this command is issued to the printer the four-byte status is
always sent via the current communication channel.
[Default] • By default ASB is enabled for all events.
GS c parameter string
Setting the real time clock
[Code] <1D>H<63>H<ASCIIZ string>
[Outline] • Sets the real time clock. The parameter string consists of six decimal
numbers in ASCII format each consisting of two digits. The numbers are
divided by space, the string ends with a NULL character.
• The parameters are in order: year, month, day, day of the week, hour,
minute.
[Default] • The initial value is not specified.