Technical Reference Manual
002-29852 Rev. *B
19.5.1.14 PASS_SAR_RESULT_VALID
Description:
Channel result data register 'valid' bits
Address:
0x409001A0
Offset:
0x1A0
Retention:
Not Retained
IsDeepSleep:
No
Comment:
Default:
0x0
Bit-field Table
Bits
7
6
5
4
3
2
1
0
Name
RESULT_VALID [7:0]
Bits
15
14
13
12
11
10
9
8
Name
RESULT_VALID [15:8]
Bits
23
22
21
20
19
18
17
16
Name
RESULT_VALID [23:16]
Bits
31
30
29
28
27
26
25
24
Name
RESULT_VALID [31:24]
Bit-fields
Bits Name
SW
HW
Default or
Enum
Description
0:31
RESULT_VALID
R
RW
0
If set the corresponding RESULT register is valid, i.e.
was acquired during the preceding group scan. If this
bit is low, after a group scan completed, then either the
channel is not enabled or is used as a pulse detect
channel.
1103
2022-04-18
TRAVEO™ T2G Automotive MCU: TVII-B-E-4M body controller entry registers