Microcontroller with LIN and Power Switches for Automotive Applications
Timer2 and Timer21
17.4.3
Timer 2 Reload/Capture Register
The RC2 register is used for a 16-bit reload of the timer count upon an overflow or a capture of the current
timer count depending on the mode selected.
Timer 2 Reload/Capture Register, Low Byte
T2_RC
Offset
Reset Value
Timer 2 Reload/Capture Register
08
H
see
Field
Bits
Type
Description
RES
31:16
r
Reserved
Always read as 0
RCH2
15:8
rw
Reload/Capture Value
Note: Reload/Capture Value can be set by software
(highest priority) and is updated by hardware during
capture mode.
These contents are loaded into the timer register upon an
overflow condition, if CP_RL2 = 0.If CP_RL2 = 1, this
register is loaded with the current timer count upon a
negative/positive transition at pin T2EX when EXEN2 = 1.
RCL2
7:0
rw
Reload/Capture Value
Note: Reload/Capture Value can be set by software
(highest priority) and is updated by hardware during
capture mode.
These contents are loaded into the timer register upon an
overflow condition, if CP_RL2 = 0.If CP_RL2 = 1, this
register is loaded with the current timer count upon a
negative/positive transition at pin T2EX when EXEN2 = 1.
Table 278 Reset
Register Reset Type
Reset Values
Reset Short Name
Reset Mode
Note
RESET_TYPE_3
00000000
H
RESET_TYPE_3
31
16
r
RES
15
8
rw
RCH2
7
0
rw
RCL2