Data Sheet
144
Rev. 1.00
2017-07-31
TLE9262BQXV33
Serial Peripheral Interface
Notes
1. A timer must be first assigned and is then automatically activated as soon as the on-time is configured.
2. If cyclic sense is selected and the HS switches are cleared during SBC Restart Mode, then also the timer
settings (period and on-time) are cleared to avoid incorrect switch detection.
TIMER2_CTRL
Timer2 Control and selection (Address 000 1101
B
)
POR / Soft Reset Value: 0000 0000
B
;
Restart Value: 0000 0000
B
7
6
5
4
3
2
1
0
Reserved
TIMER2_
ON_2
TIMER2_
ON_1
TIMER2_
ON_0
Reserved
TIMER2_
PER_2
TIMER2_
PER_1
TIMER2_
PER_0
r
r
rwh
rwh
rwh
r
rwh
rwh
rwh
Field
Bits
Type
Description
Reserved
7
r
Reserved, always reads as 0
TIMER2_
ON
6:4
rwh
Timer2 On-Time Configuration
000B , OFF / Low (timer not running, HSx output is low)
001B , 0.1ms on-time
010B , 0.3ms on-time
011B , 1.0ms on-time
100B , 10ms on-time
101B , 20ms on-time
110B , OFF / HIGH (timer not running, HSx output is high)
111B , reserved
Reserved
3
r
Reserved, always reads as 0
TIMER2_
PER
2:0
rwh
Timer2 Period Configuration
000B , 10ms
001B , 20ms
010B , 50ms
011B , 100ms
100B , 200ms
101B , 1s
110B , 2s
111B , reserved