background image

TLE4972 Current sensor programmer

User guide

About this document

This document describes feature set, hardware and software layers of the Infineon Current Sensor Programmer.

Scope and purpose

The purpose of this document is to guide the user in the programming, calibration and general evaluation of

compatible TLE4972 sensing boards using the Infineon Current Sensor Programmer.

Intended audience

This document is written for TLE4972 users who are dealing with the implementation of the product in the

system. 

Evaluation Board

Infineon’s magnetic current sensor evaluation kit consists of the Current Sensor Programmer board, USB

cable and evaluation board connection cable. The programmer GUI along with Current Sensor Programmer

board can be used to evaluate, program and calibrate Infineon’s set of evaluation boards or a customized PCB

setup. The programmer board is to be used by the customer solely for the purpose of evaluation and testing. It

is not a commercialized product and shall not be used for series production. The programmer board is thus not

intended to meet any industrial specifications and the recommended operating ambient temperature is 80°C.
 
The following key aspects are discussed in this document:

Programmer board and evaluation board order information;

Programmer board and GUI description;

Programmer board ELV and SELV isolation scheme;

GUI installation procedure;

Typical application setup with and without Infineon evaluation boards;

GUI operation with and without Infineon evaluation boards;

Easy programming of current sensor parameters such as operating mode, sensitivity, overcurrent threshold

and deglitch filtering time;

Internal signals readout (e.g. internal temperature);

Crosstalk compensation procedure;

Calibration procedure.

Table 1

Programmer and evaluation boards ordering codes

Device name

SP number

Device information

CUR SENSOR PROGRAMMER

SP004441438

Current Sensor Programmer for

TLE4972

TLE4972 EVAL STD PCB

SP005632136

TLE4972 TDSO, multi-layer FR4

board, 45° S-bend

TLE4972 EVAL INLAY

SP005632138

TLE4972 TDSO, FR4 board with

copper inlay, 45° S-bend

(table continues...)

User guide

Please read the sections "Important notice" and "Warnings" at the end of this document

Rev. 1.00

www.infineon.com

2022-04-05

Содержание TLE4972

Страница 1: ...oduction The programmer board is thus not intended to meet any industrial specifications and the recommended operating ambient temperature is 80 C The following key aspects are discussed in this document Programmer board and evaluation board order information Programmer board and GUI description Programmer board ELV and SELV isolation scheme GUI installation procedure Typical application setup wit...

Страница 2: ... Figure 1 TLE4972 Current Sensor Programmer The Current Sensor Programmer board connection with a 3 phase TLE4972 evaluation board is shown in the figure below The communication between the current sensor and programmer board is done through an interface cable Interface Cable Figure 2 TLE4972 evaluation board Green connected to Current Sensor Programmer board Red TLE4972 Current sensor programmer ...

Страница 3: ...6 4 2 3 Optional external power supply connection 17 4 2 4 Mode selection 18 4 2 4 1 Continuous readout 18 4 2 4 2 Basic configuration 18 4 2 4 3 Double Code Word Calibration 19 4 2 5 Options drop down menu 22 4 2 5 1 EXT EEPROM 22 4 2 5 2 Temperature Readout 23 4 2 5 3 Register Readout 24 4 2 5 4 EXIT 24 4 2 6 Memory drop down menu 25 4 2 6 1 Basic Configuration 25 4 2 6 2 EEPROM Map 26 4 2 6 3 C...

Страница 4: ...drivers installation 32 5 3 Abbreviations and definitions 35 5 4 References 36 6 Revision history 37 Disclaimer 38 TLE4972 Current sensor programmer User guide Table of contents User guide 4 Rev 1 00 2022 04 05 ...

Страница 5: ... which is compliant with the relevant requirements and standards of the country in which they are operated The Evaluation Boards and Reference Boards as well as the information provided in this document are addressed only to qualified and skilled technical staff for laboratory usage and shall be used and managed according to the terms and conditions set forth in this document and in other related ...

Страница 6: ...e to electrostatic discharge ESD Electrostatic control precautions are required when installing testing servicing or repairing the assembly Component damage may result if ESD control procedures are not followed If you are not familiar with electrostatic control procedures refer to the applicable ESD protection handbooks and guidelines Caution A drive that is incorrectly applied or installed can le...

Страница 7: ...d to power up the programmer board and sensors on the evaluation board or external PCB Interface cable It enables the connection and communication between programmer board and evaluation board 3 2 Main features The Current Sensor Programmer board shown in the figure below together with the GUI software constitute a ready to use evaluation setup which provides the following main features Oscillosco...

Страница 8: ...Figure 4 Current Sensor Programmer board features TLE4972 Current sensor programmer User guide 3 The board at a glance User guide 8 Rev 1 00 2022 04 05 ...

Страница 9: ...ircuits are designed to meet the ELV safety standards and the interfacing devices are designed to meet the SELV safety standards Therefore regardless of the isolation scheme used on the DUT Board a safe isolation barrier is provided by the programmer Nevertheless under all circumstances proper care must be taken while working with high voltage applications Figure 5 Current Sensor Programmer board ...

Страница 10: ...oard Load Software GUI Figure 6 Test setup of TLE4972 DUT board with programmer board Once the test set up is done the user has to to connect the programmer board through USB connection and open the GUI software in order to start the communication with the hardware If the USB connection is successful the LED D1 on the programmer board will light If the programmer board is correctly recognized by t...

Страница 11: ...ll appear Chapter 4 2 4 1 and the led D2 on the programmer board will start blinking The software GUI will automatically configure itself using configuration data stored on the Infineon evaluation board external EEPROM TLE4972 Current sensor programmer User guide 4 System and functional description User guide 11 Rev 1 00 2022 04 05 ...

Страница 12: ...selecting the Set button the tool uses the value entered here to convert the V reading into A reading in the continuous readout mode Figure 8 Connection with generic DUT board After clicking on Set the Continuous readout window will appear Chapter 4 2 4 1 and the led D2 on the programmer board will start blinking Since there is no external EEPROM on the generic DUT board the software GUI cannot co...

Страница 13: ...board have not been recognized This might be due to malfunctioning sensors or to interface problems such as soldering issues bad cabling or wrong connection scheme Figure 10 Design step not supported error TLE4972 Current sensor programmer User guide 4 System and functional description User guide 13 Rev 1 00 2022 04 05 ...

Страница 14: ...ard connector pinout Table 2 DUT board connector pinout Pin Number Pin name Pin function 1 AOUT1 Analog output voltage of sensor 1 2 OCD1_1 Over Current Detection channel 1 of sensor 1 open drain 3 VREF1 Reference voltage of sensor 1 4 OCD2_1 Over Current Detection channel 2 of sensor 1 open drain 5 AOUT2 Analog output voltage of sensor 2 6 OCD1_2 Over Current Detection channel 1 of sensor 2 open ...

Страница 15: ... 15 Reserved Additional ADC input connected to µC XMC4700 P14_9 on the programmer board 16 V5 5 V supply voltage 17 Reserved External trigger input connected to µC XMC4700 P4_0 on the programmer board 18 Reserved 19 SCL Clock for communication with external EEPROM on Infineon s evaluation boards 20 GND Ground connection 21 SDA Data link for communication with external EEPROM on Infineon s evaluati...

Страница 16: ...nout Table 3 Measurement header pinout Pin Number Pin name Pin function 1 AOUT1 Analog output voltage of sensor 1 2 OCD1_1 Over Current Detection channel 1 of sensor 1 open drain 3 VREF1 Reference voltage of sensor 1 4 OCD2_1 Over Current Detection channel 2 of sensor 1 open drain 5 AOUT2 Analog output voltage of sensor 2 6 OCD1_2 Over Current Detection channel 1 of sensor 2 open drain 7 VREF2 Ref...

Страница 17: ...mer board 18 Reserved 19 V33 3 3 V supply 20 GND Ground connection 4 2 3 Optional external power supply connection The programmer board typically draws about 350 mA when connected to the TLE4972 evaluation boards This current can be delivered via the USB port of a PC which is usually specified to deliver up to 500 mA A reverse current protection diode ensures safe operation and protects the USB po...

Страница 18: ...e pane on the top right side it displays all parameters measured for sensor 1 to sensor 3 at the last sampling event 4 Mode selection drop down menu on the top right side to start a new mode click the Stop button shown on the bottom right corner of the window and select a new mode from the Mode Selection drop down menu which is on the top right corner 5 Crosstalk matrix compensation check box it c...

Страница 19: ...nt range values 4 Nominal Sensitivity this represents the nominal sensitivity in mV A that is resulting from the choice of the current rail transfer factor and measurement range values This is the value to be used as target sensitivity for calibration 5 Basic Config button this is a shortcut for the Basic Configuration window described in Chapter 4 2 6 1 For further information about target sensit...

Страница 20: ... Itest the user has to enter in this field the test current used during calibration Measure the test current using a calibrated current source a shunt combined with a multimeter or any other precise current measurement device 4 Vout Itest button this button has to be pressed as part of the calibration procedure explained above By pressing this button the software executes the Double Code Word algo...

Страница 21: ...rors are indicated in the Step by step instructions box click on the Burn EEPROM button to store the calibration parameters in the sensor integrated EEPROM 6 Using the measurement header perform a sensitivity and offset measurement to check if the target sensitivity and offset are met Sensitivity and offset measurement procedure is explained in the User Manual 2 TLE4972 Current sensor programmer U...

Страница 22: ...wn list Figure 16 EXT EEPROM menu item The following information are programmed in the external EEPROM PCB Timestamp related to evaluation board hardware release Sensor Short Name family name of the current sensors on the evaluation board Sensor Long Name complete product name of the current sensors on the evaluation board Sensor to Output Mapping 0 is default It defines the mapping of the three s...

Страница 23: ...t to default values Save to Load from file to save and restore the external EEPROM content Burn button the external EEPROM content is effectively written in the external EEPROM after pressing the Burn button Read button to load the dialog box with values read from the external EEPROM It can be used to verify correct programming 4 2 5 2 Temperature Readout The Options drop down menu also offers the...

Страница 24: ...t is executing then analog output and OCDs output are not reliable since the sensors are put into test mode The registers accessible by the user are reported in the user manual 2 Figure 18 Registers Readout window 4 2 5 4 EXIT This menu item closes the Current Sensor Programmer GUI window TLE4972 Current sensor programmer User guide 4 System and functional description User guide 24 Rev 1 00 2022 0...

Страница 25: ...tively programmed In case an Infineon evaluation board is connected the software will ask the user whether to update the external EEPROM of the evaluation board to fit to the new programmed sensor settings as shown in the figure below The external EEPROM content is shown in Chapter 4 2 5 1 E g if the measurement range setting is changed the sensitivity of the sensors in mV A is updated in the exte...

Страница 26: ...of the content of the selected register field 4 Decimal text box on the right it displays the decimal conversion of the content of the selected register field 5 Sensor selection drop down menu on the right it is used to select the sensor for which the EEPROM content has to be displayed 6 Burn EEPROM button on the bottom it effectively programs the displayed internal EEPROM content in the selected ...

Страница 27: ...ined in details in the User manual 2 The calibration parameters should not be changed manually by the user unless directly indicated by Infineon It is strongly recommended to store the original internal EEPROM content as explained in Chapter 4 2 6 2 before modifying the internal EEPROM content Information about the calibration parameters are provided in the User manual 2 Figure 22 Calibration Para...

Страница 28: ...actor enter the nominal current rail transfer factor for the selected sensor 4 Calculate Threshold pane this section allows to calculate the resulting threshold in ampere given the OCD threshold code programmed in the corresponding internal EEPROM register of the selected sensor The OCD threshold code can be easily programmed using the Basic Configuration window Chapter 4 2 6 1 5 Calculate Registe...

Страница 29: ...ter here half of the measured value The procedure for the sensitivity measurement is explained in the User manual 2 The current rail transfer factor estimation is provided with a typical accuracy of 5 Note In order to obtain a precise estimation of the current rail transfer factor it is suggested to measure it through the method explained above on multiple systems more than 10 and to consider the ...

Страница 30: ...installation Figure 25 EvalKit Installer Welcome Read through the license agreement carefully and continue the installation by accepting it see orange color box If the license agreement is not accepted then the installation will be aborted Click Next to continue with the installation Figure 26 EvalKit Installer License Agreement TLE4972 Current sensor programmer User guide 5 References and appendi...

Страница 31: ...r Click Install to begin the installation The installation will continue if you have the admin rights otherwise the installation might be aborted without completing the installation Figure 28 EvalKit Installer Confirm Installation If the installation was successful then the following window will display Click Close to complete the software installation TLE4972 Current sensor programmer User guide ...

Страница 32: ...dow to the installer window is automatically opened at the end of the installation procedure Click on the Extract button to continue the driver installation procedure Figure 30 FTDI CDM Drivers Files Extraction The welcome wizard for the driver installation will appear after the successful extraction Click Next to continue with the installation TLE4972 Current sensor programmer User guide 5 Refere...

Страница 33: ...orange color box If the license agreement is not accepted the installation will be aborted Click Next to continue with the installation Figure 32 FTDI CDM Drivers License Agreement Click Finish to complete the device driver installation TLE4972 Current sensor programmer User guide 5 References and appendices User guide 33 Rev 1 00 2022 04 05 ...

Страница 34: ...se of connection problems go to the device manager and check whether the driver was installed correctly or not If you see the window as shown in the figure below please reinstall the driver software as described in the procedure above Figure 34 Missing RS232 HS Driver TLE4972 Current sensor programmer User guide 5 References and appendices User guide 34 Rev 1 00 2022 04 05 ...

Страница 35: ...hod GUI Graphical User Interface OCD Over Current Detection PCB Printed Circuit Board PCN Process Change Notification PD Product Discontinuation RMA Returned Material Analysis SCL Serial Clock SDA Serial Data USB Universal Serial Bus DUT Device Under Test LED Light Emitting Diode MCU Micro Controller Unit SELV Safety Extra Low Voltage ELV Extra Low Voltage TLE4972 Current sensor programmer User gu...

Страница 36: ...eon TLE4972 AE35S5 DS vxx_xx EN pdf Infineon TLE4972 AE35D5 DS vxx_xx EN pdf 2 Infineon TLE4972 User_manual vxx_xx EN TLE4972 Current sensor programmer User guide 5 References and appendices User guide 36 Rev 1 00 2022 04 05 ...

Страница 37: ...Revision history Document revision Date of release Description of changes 01 00 05 04 2022 Initial release TLE4972 Current sensor programmer User guide 6 Revision history User guide 37 Rev 1 00 2022 04 05 ...

Страница 38: ... liabilities of any kind including without limitation warranties of non infringement of intellectual property rights of any third party with respect to any and all information given in this application note The data contained in this document is exclusively intended for technically trained staff It is the responsibility of customer s technical departments to evaluate the suitability of the product...

Отзывы: