User Manual
4 of 14
Rev.1.00
2020-12-03
TLD2252-2EP rear combination lamp evaluation board
User Manual
TLD2252-2_RCL_EVAL description
1.2
Connectors and jumpers
The TLD2252-2_RCL_EVAL board connectors are described in Table 2.
Table 2
TLD2252-2_RCL_EVAL connectors
Connector
Description
INPUT
VS_STOP
Power supply, typical 8 V to 16 V, and deactivation of the internal PWM engine of the
LITIX™ Basic+ TLD2252
-2EP
VS_TAIL
Power supply, typical 8 V to 16 V, and activation of the internal PWM engine of the
LITIX™ Basic+ TLD2252
-2EP
GND
Ground
OUTPUT
GND
Ground
PWMO
LITIX™ Basic+ TLD2252
-
2EP PWM signal to drive other LITIX™ Basic devices
OUT1
External load for output channel 1, OUT1
OUT2
External load for output channel 2, OUT2
The TLD2252-2_RCL_EVAL board jumpers are described in Table 3.
Table 3
TLD2252-2_RCL_EVAL board jumpers
Jumper
Description and configuration
JPN_SET1
Sets the output current of OUT1:
•
RIN_SET1_1 (36.5 k
Ω
): sets the output current to 10 mA
•
RIN_SET1_2 (7.32 k
Ω
): sets the output current to 50 mA
JPPWMO
PWM output enable:
•
IN_SET1: enables PWM at OUT1
•
IN_SET2: enables PWM at OUT2
JPN_SET2
Sets the output current of OUT2:
•
RIN_SET2_1 (14.7 k
Ω
): sets the output current to 50 mA
•
RIN_SET2_2 (7.32 k
Ω
): sets the output current to 100 mA
JPEN2/DEN2
Activate the device and diagnosis for OUT2:
•
EN1/DEN1: use the resistor divider on EN1/DEN1 (REN1/DEN1_1) to activate OUT2
•
EN2/DEN2: use separate resistor divider EN1/DEN1 (REN1/DEN1_1) to activate
OUT2. During tail function (board supplied via VS_TAIL), place jumper on
EN1/DEN1 position
JPOUT
On board load connection
•
OUT1: connects OUT1 to on-board load
•
OUT2: connects OUT2 to on-board load
JPD
Diagnosis management
•
GND: when a fault is detected only the channel under fault condition will be
deactivated. The error will be communicated via ERRN