Delta Treatment Systems • 9125 Comar Drive, Walker, LA 70785 • 1-800-219-9183 • www.deltatreatment.com
15
CP2210 SCHEMATIC
BY OTHERS (20 AMP MAXIMUM
)
BRANCH CIRCUIT CONNECTION
EXTERNAL DISCONNECT AND
SHOR
T CIRCUIT RA
TING: 5KA
VOL
TS - 120
PHASE/HZ - 1/60
TYPE 4X ENCLOSURE
MAX FULL LOAD AMPS -
8
CP2210/ECO/FG/UL CONTROL
PA
NEL
SETTING HIGH LEVEL PRESSURE SWITCH
– BRING PLANT TO OPERA
TING
WA
TER LEVEL
WITH COMPRESSOR TURNED ON. – USING PROPERL
Y SIZED SCREWDRIVER, TURN
HIGH LEVEL ALARM ADJUSTMENT
.
– SCREW CLOCKWISE UNTIL ALARM OCCURS. THEN TURN THE SCREW COUNTERCLOCKWISE UNTIL ALARM STOPS.
EXTERNAL WIRING
SW1
G
N
H
FS1
F1
F2
R
120V
AC
C
H
NG
LT
1
FU1
G
N
HIGH LEVEL ALARM
FLOA
T SWITCH
LOW LEVE
L
HIGH LEVE
L
PS
PS
SCHEMA
TIC DIAGRAM
HIGH LEVEL ALARM ADJUSTMENT SCREW
GROUND
PS
F2
H
F1
FS
1
FUSE
N
N
COM
P.
TO
TB
FUSE
*TIME DELA
Y
H
GN
120
VA
C
SOURCE
COMP
.
TO
G
TO COMP
.
AIR LINE
CP2210/ECO/FG/UL
NTS
A
CP2210
10/03/07
1
1
D.WRIGHT
MOTOR FULL
LOAD CURREN
T
1-4 AMPS
4-8 AMPS
12-16 AMPS
8-12 AMPS
FUSE SELECTION CHAR
T
15 AMPS
10 AMPS
20 AMPS
5 AMPS
TYPICAL TIME DELA
Y
FUSE SIZE REQUIRED
CR
T
PA
RT
NO
.
AE845-4187
AE845-4188
AE845-4180
AE845-4184
BUZZ
REVISION DESCRIPTION
REV.
DATE
INFORMATION CONTAINED HEREIN IS CONFIDENTIAL,
SOLELY FOR THE PURPOSE PROVIDED, AND IT IS NOT TO BE DISCLOSED TO
COMPANY CONFIDENTIAL
IT IS THE PROPERTY OF DELTA TREATMENT SYSTEMS, IT IS TO BE USED
OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF DELTA TREATMENT SYSTEMS.
BY
PLOT SCALE
SHEET
OF
DRAWN BY
DATE
REV
DRAWING NUMBER
CP2210 SCHEMATIC