Technical parameters 

Warning

Before the device is installed and operated, read this instruction manual carefully and with full 
understanding and Installation Guide System iNELS3. The instruction manual is designated for 
mounting the device and for the user of such device. It has to be attached to electro-installation 
documentation. The instruction manual can be also found on a web site www.inels.com. Attention, 
danger of injury by electrical current! Mounting and connection can be done only by a professional 
with an adequate electrical qualifi cation, and all has to be done while observing valid regulations. 
Do not touch parts of the device that are energized. Danger of life-threat! While mounting, 
servicing, executing any changes, and repairing it is essential to observe safety regulations, norms, 
directives and special regulations for working with electrical equipment. Before you start working 
with the device, it is essential to have all wires, connected parts, and terminals de-energized. This 
instruction manual contains only general directions which need to be applied in a particular 
installation. In the course of inspections and maintenance, always check (while de-energized) if 
terminals are tightened.

Outputs

Output:

Switching voltage:

Switching output:

Surge current:

Output relays separated

from all internal circuits:

Isolation between relay

inputs COM1 and COM2:

Isolation between individual

relay outputs:

Isolates. voltage open

relay contact:

Max. current terminals

COM1 and COM2:

Min. switched current:

Switching frequency /

no load:

Switching frequency /

rated load:

Mechanical life:

Electrical life AC1:

Output indication:

Communication

Installation BUS:

Power supply

Supply voltage / tolerance:

Dissipated power:

Rated current:

Status indication unit:

Connection

Terminal:

Operating conditions

Air humidity:

Operating temperature:

Storing temperature:

Protection degree:

Overvoltage category:

Pollution degree:

Operation position:

Installation:

Design:

Dimensions and weight

Dimensions: 

Weight:

6x changeover 8 A/AC1

250 V AC1, 24 V DC

2000 VA/AC1, 192 W/DC

10 A

reinforced Insulation 

(Cat. II surges by EN 60664-1) 

reinforced Insulation 

(Cat. II surges by EN 60664-1) 

basic insulated.

(Cat. II surges by EN 60664-1) 

1 kV

16 A

100 mA / 5 V DC

300 min

-1

15 min

-1

2x 10

7

5x 10

4

6x yellow LED

BUS

27 V DC, -20 / +10 %

9 W

60 mA (at 27 V DC), from BUS 

green LED RUN

max. 2.5 mm

2

 / 1.5 mm

2

 with sleeve

max. 80 %

-20 .. +55 °C

-30 .. +70 °C

IP20 device, IP40 mounting in the switchboard 

II.

2

any

switchboard on DIN rail EN 60715

3-MODUL

90 x 52 x 65 mm

175 g