02-8/2018 Rev.1
RFSAI-62B
Dual Band wireless switching component input button
EN
Made in Czech Republic
PROG
>
8s
1 x
PROG
>
11s
1 x
Delete actuator /
Deleting one position of the transmitter /
By pressing the programming button on the actuator for 8 sec-
onds, deletion of one transmitter activates. LED flashs 4x in each
1s interval.
Pressing the required button on the transmitter deletes it from
the actuator's memory.
To confirm deletion, the LED will confirm with a flash long and
the component returns to the operating mode. The memory
status is not indicated.
Deletion does not affect the pre-set memory function.
Deleting the entire memory /
By pressing the programming button on the actuator for
11 seconds, deletion occurs of the actuator's entire memory.
LED flashs 4x in each 1s interval.
The actuator goes into the programming mode, the LED flashes
in 0.5s intervals (max. 4 min.).
You can return to the operating mode by pressing the Prog but-
ton for less than 1s. The LED lights up according to the pre-set
memory function and the component returns to the operating
mode.
Deletion does not affect the pre-set memory function.
Selecting the memory function /
• Memory function on:
- For functions 1-4, these are used to store the last state of the relay output before the supply
voltage drops, the change of state of the output to the memory is recorded 15 seconds after
the change.
- For functions 5-6, the target state of the relay is immediately entered into the memory after
the delay, after re-connecting the power, the relay is set to the target state.
• Memory function off:
When the power supply is reconnected, the relay remains off.
1
2
Press of programming button on receiver RFSAI-62B for 3-5 sec-
ond will activate receiver RFSAI-62B into programming mode.
LED is flashing in 1s interval.
Pressing the programming button on the RFSAI-62B receiver for
less than 1 second will finish the programming mode, this will re-
verse the memory function. The LED lights up according to the
current pre-set memory function. The set memory function is
saved.
Every other change is made in the same way.
PROG
<
5s
1 x
PROG
<
1s
1 x
6/
7
www.elkoep.rs
U-Energister, d.o.o.| Noveških interniraca 1V | 31000 Užice | Serbia | e-mail: [email protected]
U-Energister, d.o.o. | Norveških interniraca 1V | 31000 Užice | Republika Srbija | e-mail: [email protected]
EN
Support: +381 63 479 880 |
RS
Tehnička podrška +381 63 479 880
Dvokanalna prekidačka jedinica
RS
Brisanje elemenata
Brisanje jednog položaja na
Pritiskom na taster PROG koji se nalazi na RFSAI-62B u trajan-
ju od 8s aktivira se brisanje jednog kontrolera. LED 4x trepće
u intervalu od 1s.
Pritiskom na taster na kontroleru briše se iz memorije ele-
ment.
Da bi se potvrdilo brisanje, LED lampica trepće dugo vre-
mena i element se vraća u režim rada. Status memorije nije
Brisanje cele memorije
Pritiskom na taster PROG na elemetru RFSAI-62B u trajanju
od 11s, briše se celokupna memorija elementa. LED trepće 4x
u intervalu od 1s. Element se zatim prebacuje u režim progra-
miranja, LED trepće u intervalu 0,5s ( maksimum 4 minuta).
Da bi se vratili u režim rada, pritisnite taster PROG manje od
1s. LED će svetleti u skladu sa podešenom funkcijom memo-
rije i element se vraća u režim rada.
Brisanje ne utiče na podešenu funkciju memorije.
Izbor funkcije memorije
Pritiskom na taster PROG u trajanju od 3-5s element se preba-
cuje u režim programiranja. LED lampica treperi u intervalu od
1s.
Pritiskom na taster za programiranje na RFSAI-62B prijemniku
kraći od 1s, režim programiranja će se završiti, a memorijska
funkcija će se preokrenuti. LED svetli u skladu sa trenutno
unapred podešenom funkcijom memorije. Podešena funkcija
memorije je sačuvana.
•Funkcija memorije na:
- Za funkcije 1-4, 7, 8, koje se koriste za čuvanje poslednjeg stanja relejnog izlaza pre ne-
stanka napajanja.Promena stanja izlaznog releja se zapisuje u memoriju svakih 15s na-
kon štoje izvršena promena.
- Za funkcije 5,6 ciljno stanje izlaznog releja se trenutno upisuje u memoriju nakon unosa
vremena kašnjena. Nakon ponovnog povezivanja napajanja, izlazni relej se postavlja u
ciljno stanje.
• Isključenje funkcija memorije: