Connecting the eLAN-IR-003  

 

 

Connect the eLAN-IR-003 to the power supply. 

 

Using the Ethernet cable, connect the eLAN to your local network. Your local network (router) 
assigns the eLAN-IR-003 an IP address. 

 

Connect to output IR1 (IR2, IR3) IR transmitter (included in package). Place the IR transmitter 
at  the  required  distance  from  the  controlled  device.  Turn  the  IR  transmitter  to  the  position 
based on the emission characteristics (see point 4.2). 

 

Test the function of the IR connection. Affix the IR transmitter at the required spot using tape 
on the IR transmitter. 

 

Example of typical connection 

 

 

 

 

Содержание eLAN-IR-003

Страница 1: ...Rev 1 Page 1 of 15 eLAN IR 003 ...

Страница 2: ...eLAN IR 003 3 3 Technical parameters 4 4 Hardware installation 5 4 1 Description of eLAN IR 003 5 4 2 Requirements for installation 6 4 3 Connecting the eLAN IR 003 7 5 Configuring the eLAN IR 003 8 5 1 Configuration panel 9 5 2 Description of functions 10 6 Troubleshooting 15 ...

Страница 3: ... multimedia from the iHC app or when an iMM shows an IR signal it can control the TV an amplifier and smart phone or a tablet and gyroscopic mouse and it serves as the sole driver of the entire system An independent facility or an IR terror drivers which unites all drivers under one and replacing it with a smart phone without having to use iNELS complex system eLAN IR 003 converter Ethernet comman...

Страница 4: ...erface 10 100 Mbps RJ45 POWER SUPPLY Voltage supply rated current 10 27 V DC 200 mA safe low voltage Connection Jack connector O 2 1 mm Voltage supply indication Green LED OTHER DATA Other possibilities of wiring USB B connector Indication Yellow USB LED status Reset button settings to their default values Power supply 230 V AC 12 V DC supplied with the data logger OPERATING CONDITIONS Operating t...

Страница 5: ...t the USB port LED indicator of Ethernet yellow operation status indicator green communication indicator Input for connector Ethernet RJ45 for connection to local network LAN or PC RESET button RESTART press 1s performs device restart current settings do not change RESET press 10s returns device to factory settings i e reading IP address from DHCP user name and password set to admin user elkoep de...

Страница 6: ... IR 003 may not be placed in a spot where it would be exposed to moisture or excessive temperatures The connected IR transmitter must be in directionally and visibly aligned with the receiver and at an adequate distance from the controlled device For flawless IR communication the transmitter cannot become contaminated The emission characteristics of the transmitter are displayed by a symbol in the...

Страница 7: ... eLAN IR 003 an IP address Connect to output IR1 IR2 IR3 IR transmitter included in package Place the IR transmitter at the required distance from the controlled device Turn the IR transmitter to the position based on the emission characteristics see point 4 2 Test the function of the IR connection Affix the IR transmitter at the required spot using tape on the IR transmitter Example of typical co...

Страница 8: ...nits appear that are located in your home network to which you are currently connected by phone as well as their IP addresses Run the web browser In the Internet browser in the Address panel fill in the IP address of your eLAN IR 003 After confirming the entered IP address the web server s login page will come up A sign in window will appear on the start screen Factory settings for signing in as a...

Страница 9: ...Rev 1 Page 9 of 15 eLAN IR 003 5 1 Configuration panel ...

Страница 10: ...b interface eLAN IR 003 By pressing the button Save settings you can save the current settings of your eLAN IR 003 including network settings By pressing the button Load settings you can restore your stored settings which you have already stored in your PC the file has the extension bin The button Settings is to configure network settings that you can change any time based on your network ...

Страница 11: ...Website http www elkoep cz ke stazeni software If you are experiencing no difficulties with the eLAN IR it is not necessary to download the latest firmware version Panel Rooms create a room Button add a new room 1 ID of the room optional data if you do not enter it a number is automatically generated Here you can only use the characters 0 9A Za z_ 2 Label gives an arbitrary name to the room you ca...

Страница 12: ...or the needs of R D The panel Room Types do not adjust or delete anything only for the needs of R D Panel Action displays options for controlling the device indicated on the floor plan Panel Scenes create a scene ATTENTION You can only create scenes after adding a device see Devices and loading IR codes for individual device functions see IR codes Button add a new scene 1 ID name of room not requi...

Страница 13: ...eate IR device will appear where you will enter the device name Label and type of device Type By clicking on the button the window Create Action will appear where you select commands 1 Name name of function 2 IR LED selection of IR transmitter which the device is supposed to control 3 IR codes selection of loaded IR code from the list Available Confirm by pressing Create Button delete selected com...

Страница 14: ...pressing this activates the IR signal receiver on the eLAN IR 003 Then you can load codes from the controller Import if you have IR codes stored in your PC you can load them directly You can verify receipt of the IR codes directly in the Configuration panel where you will see displayed in the Status row Status Recording IR code Button deletes the selected code Button X deletes all codes ...

Страница 15: ...for 1 s or by disconnecting and reconnecting the power supply The device does not react to sent IR commands Recheck connection to the power source and to the Ethernet network connection of the IR transmitter to the applicable IR transmitter output flashing LED STATUS of the applicable IR transmitter output when sending the IR signal If the LED STATUS is not flashing the cause may be an incorrectly...