Preface 

 

This User Guide is been implemented by Boot & Work, S.L. working 
under the name Industrial Shields.  

 

Purpose of the manual 

The information contained in this manual can be used as a reference to operating, to 
functions, and to the technical data of the signal modules, power supply modules and 
interface modules. 

 

 

Intended Audience 

This User Guide is intended for the following audience: 

 

Persons in charge of introducing automation devices. 

 

Persons who design automation systems. 

 

Persons who install or connect automation devices. 

 

Persons who manage working automation installation. 
 
 

   

Warnings: 

 

 

Unused pins should not be connected. Ignoring the directive may damage the 
controller. 

 

Improper use of this product may severely damage the controller. 

 

Refer to the controller’s User Guide regarding wiring considerations. 

 

Before using this product, it is the responsibility of the user to read the product’s User 
Guide and all accompanying documentation. 

 

Maintenance must be performed by qualified personnel familiarized with the 
construction, operation, and hazards involved with the control.  

 

 Maintenance should be performed with the control out of operation and 
disconnected from all sources of power.  

 

Care should be taken when servicing electrostatic sensitive components. The 
manufacturer's recommendations for these components should be followed.  

 

The Spartan Arduino PLC is Open Type Controller. It is required that you install the 
Spartan Arduino PLC in a housing, cabinet, or electric control room. Entry to the 

Содержание 017001001200

Страница 1: ...SPARTAN ARDUINO PLC PLC ARDUINO SPARTAN...

Страница 2: ...Ref 017001001200 Rev 0 06 04 20 1...

Страница 3: ...Ref 017001001200 Rev 0 06 04 20 2 SPARTAN ARDUINO PLC User Guide Revised March 2020 This user guide is for version Spartan Arduino PLC with Reference name Ref 017001001200...

Страница 4: ...g the directive may damage the controller Improper use of this product may severely damage the controller Refer to the controller s User Guide regarding wiring considerations Before using this product...

Страница 5: ...doit tre effectu e par personnel qualifi familiaris avec la fabrication le fonctionnement et les dangers li s au contr leur La maintenance doit tre effectu e avec l quipement hors service et d connect...

Страница 6: ...any codes regulations or standards that apply to the combination of products in the customer s application or use of the product The following are some examples of applications for which particular at...

Страница 7: ...risks resulting from the handling or manipulation of such products systems and to avoid possible hazards Disclaimers Weights and Dimensions Dimensions and weights are nominal and they are not used fo...

Страница 8: ...during commissioning operation maintenance and repairs caused by for example Hardware defects and or software errors in the sensors controllers actuators and connection technology Response times of t...

Страница 9: ...D THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE INDUSTRIAL SHIELDS DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED Limitations of Liability INDUSTRIAL SHIELDS SHALL NOT...

Страница 10: ...14 5 How to connect PLC Arduino to PC 17 6 How to connect PLC to power supply 18 7 Ardbox Analog I O pinout 19 Zone Connections 19 8 Switch configuration 23 General Switches Configuration 23 RS 485 S...

Страница 11: ...rated PCB ground Rated Voltage 10Vac 7 to 24Vdc I min 2 to 12 mA Galvanic Isolation Rated Voltage 24 Vdc Interrupt isolated Input HS 24Vcc 7 to 24Vdc I min 2 to 12 mA Galvanic Isolation Rated Voltage...

Страница 12: ...stance 80m s2 in the X Y and Z direction 2 times each Ambient temperature operating 0 to 60 C Ambient humidity operating 10 to 90 no condensation Ambient environment operating With no corrosive gas Am...

Страница 13: ...lse General To identify the control by which a pulse is started IEC 60417 Graphical symbols for use on equipment 5017 Earth Ground To identify an earth ground terminal in cases where neither the symbo...

Страница 14: ...no PLC under different conditions from what has been specified in this manual or integrating Spartan Arduino PLC to nuclear control systems railroad systems aviation systems vehicles combustion system...

Страница 15: ...PLCs much easier Basically it is no needed to define the pins and if that pins are inputs or outputs Everything is set up automatically if using the boards In order to install Industrial Shields boar...

Страница 16: ...Ref 017001001200 Rev 0 06 04 20 15 4 Go to Tools Board Boards Manager 5 Search for industrialshields...

Страница 17: ...llowing this steps you will be able to use now the Industrial Shields Boards Also there are some examples of programming in File Examples Spartan Arduino PLC Furthermore there are some extra libraries...

Страница 18: ...0 06 04 20 17 5 How to connect PLC Arduino to PC Connect USB port from PLC to PC NOTE Ardbox Family uses micro USB cable Open Arduino IDE interface Select Industrial Shields boards Spartan Arduino PLC...

Страница 19: ...regardless of where use of the device is intended The equipment must be powered from an external power source in accordance with IEC 61010 1 whose output is MBTS and is limited in power according to...

Страница 20: ...log Out Analog Out Analog Out Analog Out Not Connected Not Connected Analog Out Digital Output Digital Output Digital Output PWM digital Output PWM digital Output PWM digital Output PWM digital Output...

Страница 21: ...C 5V RESET SCK MOSI MISO I0 7 I0 6 I0 5 I0 4 I0 3 I0 2 I0 1 NC NC I0 01 3 2 18 19 20 21 22 23 8 2 3 2 4 8 18 19 20 21 22 23 8 2 RS485 A RS485 B Not Connected Not Connected SCL I2C SDA I2C Not Connecte...

Страница 22: ...or Communications configuration Enabling Communications disables some I Os Communications pins Digital Analog Inputs RIGHT ZONE Switch config see section 8 for Communications configuration Enabling Co...

Страница 23: ...to enable these connections 2 See section 9 to enable these connections NOTE These Pins are not connected DEFAULT SERIGRAPHY CORRECT SERIGRAPHY SDA PIN2 SDA PIN2 NC NC NC NC GND GND Input Output Powe...

Страница 24: ...n SDA I2C Pin2 and I0 0 If this switch is ON the I0 0 input will be enabled and the SDA Pin3 will be disabled If this switch is OFF the SDA Pin2 will be now available and I0 0 disabled 1 SCL D3 Q0 6 C...

Страница 25: ...and for OFF Analog Output 4 ON position Half Duplex OFF position Full Duplex 3 ON position Q0 4 OFF position A0 4 2 ON position Q0 3 OFF position A0 3 1 ON position Q0 2 OFF position A0 2 4 ON positi...

Страница 26: ...ne are configured as it is showed in the table The ones marked with mean that they don t affect the RS 485 communication protocol I2C Switch configuration I2C Enable SCL and SDA connections direct Ard...

Страница 27: ...in order to work with the I2C an external pull up resistor is required If it is meant to work as a GPIO at 5V the switches must be set as I2C section 8 These pins are not stablished with a pull up or...

Страница 28: ...Ref 017001001200 Rev 0 06 04 20 27 10 I 0 technical details Digital Output Waveform Digital Output Turn off...

Страница 29: ...Ref 017001001200 Rev 0 06 04 20 28 PWM Waveform Analog Out Turn on Analog Out Turn off...

Страница 30: ...Ref 017001001200 Rev 0 06 04 20 29 Analog Digital Input Turn on Analog Digital Input Turn off...

Страница 31: ...Ref 017001001200 Rev 0 06 04 20 30 11 Typical Connections...

Страница 32: ...Ref 017001001200 Rev 0 06 04 20 31...

Страница 33: ...Ref 017001001200 Rev 0 06 04 20 32...

Страница 34: ...Ref 017001001200 Rev 0 06 04 20 33...

Страница 35: ...06 connector from Phoenix contact FK MC 0 5 10 ST 2 5 Connection details Article reference MC 0 5 10 G 2 5 THT Height 8 1mm Pitch 2 5mm Dimension 22 5mm Pin dimensions 0 8x0 8mm Pin spacing 2 50mm Art...

Страница 36: ...Ref 017001001200 Rev 0 06 04 20 35 13 Spartan Arduino PLC Dimensions 45mm width DIN rail mounting...

Страница 37: ...itches and contactors in a dedicated electric cabinet and keep the cabinet ventilated If the location has high ambient temperature or heat generating equipment nearby install forced convection devices...

Страница 38: ...water or oil periodic inspection with filter replacement when necessary should be made of these systems The means employed for grounding or insulating the equipment from ground should be checked to a...

Страница 39: ...sufficient tightening can lead to loose parts or wires and cause malfunctions Excessive tightening can damage the screws and or the module with the risk of falling short circuits and malfunctions Befo...

Страница 40: ...Ref 017001001200 Rev 0 06 04 20 39 15 Revision Table Revision Number Date Changes 0 06 04 2020 First Implementation...

Страница 41: ...04 20 40 About Industrial Shields Direction F brica del Pont 1 11 Zip Postal Code 08272 City Sant Fruit s de Bages Barcelona Country Spain Telephone 34 938 760 191 34 635 693 611 Mail industrialshiel...

Страница 42: ...50401 FT1A C12RA W 88981106 H2CAC24A H2CRSAC110B R88A CRGB003CR E R88ARR080100S R88A TK01K DCN1 1 AFP0RT32CT DRT2ID08C DTB4896VRE DTB9696CVE DTB9696LVE E53 AZ01 E53E01 E53E8C E5C4Q40J999FAC120 E5CWLQ1...

Отзывы: