SAFETY

PLEASE READ THE FOLLOWING INSTRUCTIONS CAREFULLY BEFORE INSTALLING, 

OPERATING OR SERVICING YOUR AIR CLEANER. IT IS THE USER’S RESPONSIBILITY TO 

BECOME FULLY AQUAINTED WITH THE CONTENTS OF THE MANUAL AND THE PROPER 

OPERATION OF THE EQUIPMENT PRIOR TO USE.

Follow all building and safety codes when installing this equipment.  Pertaining but not limited to, 

the Occupational Safety and Health Act (OSHA),  National Electric Code (NEC), Uniform Building 

Code (UBC), National Fire Prevention Act (NFPA) & all state and local codes.  

 

All electrical connections should be performed by a qualified electrician. 

 

Keep Flammable Objects away from the air cleaner and under no condition should a burning 

object be allowed into the air cleaning system. 

 

Do not mix materials collected in your Air Cleaner.  Materials collected could create a hazardous 

environment or a condition of operation for which the equipment was not intended.  The 

Manufacturer is relieved of any liability if this unit is not used according to this manual. 

 

Do not use the air cleaner for an application other than for which it was intended.  Consult your 

distributor, Applicable Codes, or call Industrial Maid for application assistance. 

 

Fire protection is not included. Please consult your local fire protection specialist for any required 

extinguishing equipment. 

 

Consult with your insurance underwriter about any other protection from fire damages. 

 

The Manufacturer reserves the right to make design changes which may improve the air cleaner. 

 

This unit is intended for use to collect weld fume, dust, smoke and other airborne pollutants in 

industrial and manufacturing Facilities .  Do not use for the collection of flammable or explosive 

metals, dusts, fumes or other potentially hazardous materials.

INSPECTION

Upon receiving your Industrial Maid air cleaner, please inspect for any damage incurred during 

shipment. Inspect carefully; some damage may not be noticeable until the unit is installed. Notify 

your shipper of any damage immediately. Claims must be filed with the shipper within 15 days. 

Freight damage claims are the responsibility of the purchaser.

Содержание AZTech RH 60 Series

Страница 1: ...1 Owners Manual AZTech Model RH 60 SERIES WELDING HOOD AIR CLEANER...

Страница 2: ...2 Contents Safety Inspection 3 Specifications 4 Installation 5 Replacement Parts 6 Direct Drive Replacement Parts 8 Electrical 9 Filter Maintenance 10 Troubleshooting 15 Warranty 20 Appendix 23...

Страница 3: ...bility if this unit is not used according to this manual Do not use the air cleaner for an application other than for which it was intended Consult your distributor Applicable Codes or call Industrial...

Страница 4: ...7 amps OPT 7 5 HP 208 230 460 3 60 20 19 9 5 amps Air Volume 6500 CFM 75 W G Motor STD 5 HP 208 230 460 3 60 TEFC wired to junction Box OPT 7 5 HP 208 230 460 3 60 TEFC wired to junction Box Blower S...

Страница 5: ...he air cleaner plus the additional weight of the material collected Consult your local building code for proper installation methods and materials Failure to use the proper materials could result in i...

Страница 6: ...0060 11CS 2 5 16 GA POWDERCOATED PANELS TOP SIDE 6B 000060 10CS 1 16 GA POWDERCOATED PANELS EXHAUST 6C RH60 12 RHAP 1 16 GA POWDERCOATED PANELS MOTOR ACCESS 7 FR60 ASSY 2 4 14 GA FRAME ASSEMBLY 8 GR09...

Страница 7: ...02 4 8 PLENUM FRAME 17 LL 4T54N C 3 2 48 DUSTPROOF LED LIGHT KIT 18 MT05 184M 1 MOTOR BASE 19 354580 PL1CS 8 12 16 GA STEEL PLENUM SIDE PANELS 20 354580 PL2CS 4 8 16 GA STEEL PLENUM END PANELS 21 RH3...

Страница 8: ...BWBI T355 1 TEK 355 COMPOSITE BI WHEEL 3 ICBI T355 1 TEK 355 INLET CONE 4 M36V D 355 1 DIRECT DRIVE MOTOR CABINET 5HP 5 GR018 0018 1 18X18 EXHAUST GRILLE 6 HD35 44ST 1 MOTOR ACCESS PANEL 7A RH35 DD12...

Страница 9: ...se motors can be reversed by switching leads L1 and L2 VERIFY rotation before operating the air cleaner to avoid over amping the motor voiding warranty After completion of the field wiring turn the un...

Страница 10: ...ned for the safe operation of the RH series hood PLEATED PREFILTERS The RH Series hoods are supplied with a standard 4 pleated pre filter FP44 2424 rated Class 2 under UL standard 900 operating temper...

Страница 11: ...00kcmil 4 0 3 600kcmil 400kcmil 1 0 1250kcmil 800kcmil 4 0 150 350kcmil 250kcmil 2 700kcmil 500kcmil 2 0 1500kcmil 900kcmil 250kcmil 200 500kcmil 350kcmil 1 0 1250kcmil 800kcmil 4 0 1750kcmil 1250kcmi...

Страница 12: ...3 6 12 3 8 1 0 6 2 0 4 4 0 3 5 10 6 4 2 1 7 1 2 8 6 3 1 1 0 10 8 4 2 1 0 2 0 Table B Minimum Wire Sizes for Single Phase Motors Type S SO SJ SJO etc Flexible cable wire sizes See NEC Article 400 for...

Страница 13: ...tor serviced by a qualified motor repair shop before operating Recommended Maintenance Remove dirt accumulations in and around vent openings by vacuuming Dirt accumulations can cause motor overheating...

Страница 14: ...months Heavy duty use in dirty dusty locations high ambients moisture laden atmosphere constant vibration 4 Months 4 Months 3 Months NOTE 1 Motors operating faster than 1800 RPM should be relubricated...

Страница 15: ...nd reset overload relay in starter Check heater rating against motor nameplate current rating 4 Overload internal thermal protector tripped 4 Check motor load If motor has an automatic or manual reset...

Страница 16: ...loaded bearings 4 Replace bearings check loading and alignment 5 Defective winding Bent or bowed shaft 5 Repair or replace 6 Loose sheave or misaligned coupling 6 Tighten set screw s realign coupling...

Страница 17: ...ate or terminal box cover 2 Follow motor manufacturer s instructions for motor lubrication Remove excess lubricant 3 Follow Replacement Parts Manual for blower bearing lubrication 4 Check wiring to ma...

Страница 18: ...Too much air flow 1 Blower speed too high 1 Check for correct drives 2 Filter s not in place 2 Install filter s Unit fails to operate 1 Blown fuse or open circuit breaker 1 Replace fuse or reset circu...

Страница 19: ...____ HP________________________ VOLTAGE____________________MFG DATE__________________ VOLTAGE L1_______________________L2________________________L3____________________ AMP DRAW L1_____________________...

Страница 20: ...apply to covered defects in Components that are discovered by Owner within the respective thirty six 36 months or twelve 12 months following the Invoice Date the Warranty Period and are reported to I...

Страница 21: ...or any third party to a properly handle transport and or store any Industrial Maid Components b properly select and prepare a location that is adequate for where the Industrial Maid Components will be...

Страница 22: ...COST PAID BY OWNER AS TO SUCH NON CONFORMING COST OF SUCH NON CONFORMING GOODS OR SERVICES C Limitation on the Nature of Damages EXCEPT AS EXPRESSLY PROVIDED IN SECTION 4 ABOVE INDUSTRIAL MAID SHALL N...

Страница 23: ...23 APPENDIX A Hood Assembly 4 Hood Corners 4 Hood Sides 4 Hood Ends 2 Light Fixtures 36 1 4 x 1 Self Threading Bolts 36 1 4 x 1 Bolts Nuts Lock and Flat Washers...

Страница 24: ...your way around the entire hood STEP 3 Make sure Pieces are Level then Tighten all bolts Tighten the self threading bolts first then the hood pieces together STEP 4 Fasten curtain to bottom of hood u...

Страница 25: ...5 26 3 8 X 1 BOLT FLAT WASHER LOCK NUT 6 1 RH60 SERIES AIR CLEANER STD 7 1 RH60 SERIES HOOD KIT STD 8 8 1 2 X 5 BOLT WASHER AND LOCK NUT OTHER ITEMS REQUIRED FOR INSTALLATION 16 3 8 X 6 ANCHOR BOLTS 9...

Страница 26: ...the desired location and elevate to install support columns Brace the unit to avoid fall 5 Carefully slide a 4 x 4 column into each support bracket and tighten all for pre installed 1 2 x 1 bolts Mak...

Отзывы: