background image

 9 

industrialaircontractor.com

 

 

Please contact 1-888-895-4549 for further assistance.

B

A

D

E

I

H

C

J

Pre-Operation (continued)

SYSTEM COMPONENTS

Part

Description

A

ON ( I )/OFF ( 0 ) Switch: 

Turn this switch in the “ON ( I )” position to provide automatic power to the 

pressure switch and “OFF ( O )” to remove power at the end of each use.

B

Safety Valve: 

If the pressure switch does not shut off the air compressor at its “cut-out” pressure 

setting, the safety valve will protect against high pressure by “popping out” at its factory set pressure 

(slightly higher than the pressure switch “cut-out” setting).

C

Tank Pressure Gauge: 

 The tank pressure gauge indicates the reserve air pressure in the tank. 

D

Air Compressor Pump: 

 Compresses air into the air tank. Working air is not available until the 

compressor has raised the air tank pressure above that required at the air outlet.

E

Drain Valve

: The drain valve is located at the base of the air tank and is used to drain condensation at 

the end of each use.

F

Check Valve: (not shown) 

When the air compressor is operating, the check valve is “open”, allowing 

compressed air to enter the air tank.  When the air compressor reaches “cut-out” pressure, the check 

valve “closes”, allowing air pressure to remain inside the air tank.

G

Thermal Overload Reset: (not shown) 

This motor has a manual thermal overload protector. If the motor 

overheats for any reason, the overload protector will shut off the motor.  The motor must be allowed to 

cool down before restarting.  To restart:
1. Place the ON/OFF switch in the “OFF” (0) position.
2. Unplug the air compressor and wait until the compressor cools down.
3. Plug the air compressor into and approved outlet.
4. Place the ON/OFF switch in the “ON” (I) position to restart the motor.

H

Regulator: 

Valve used to ensure that the tank pressure never reaches unsafe levels. It also allows the 

user to adjust the pressure coming out of the tank to match what is needed for the task.

I

Pressure Regulator Gauge:

 The gauge that indicates the amount of pressure that the regulator is 

providing to the tool.

J

Quick Connects: 

Fittings that are designed to accept a hose that allows pressure to be released for tool 

usage.

Содержание C041I

Страница 1: ...PERFORMANCE CREW COMPRESSOR Questions problems missing parts Before returning to the store call Customer Service 8 a m 6 p m EST Monday Friday PRODUCT SERVICE 888 895 4549 industrialaircontractor com...

Страница 2: ...of flammable liquids gases or dust Power tools create sparks which may ignite the dust or fumes Keep bystanders children and visitors away while operating tools Distractions can cause you to lose con...

Страница 3: ...andle When the location is reached slowly lower the compressor to the ground Always store the compressor in a horizontal position resting on the rubber bumpers When transporting the compressor in a ve...

Страница 4: ...er direct a jet of compressed air toward people or animals Protect your lungs Wear a face or dust mask if the operation is dusty Do not use this air compressor to spray chemicals Your lungs can be dam...

Страница 5: ...will not get caught on lumber tools or other obstructions while you are working with a power tool Failure to do so can result in serious personal injury WARNING Check extension cords before each use I...

Страница 6: ...accordance with all local codes and ordinances WARNING Improper installation of the grounding plug may result in a risk of electric shock When repair or replacement of the cord or plug is required do...

Страница 7: ...or industrial applications Rental applications render this warranty null and void Labor service calls and travel charges are not covered after the first year of ownership on stationary compressors co...

Страница 8: ...Lubrication Oil free Input 120V 60 Hz Single phase AC only 15 Amps Minimum branch circuit requirement 15 A Fuse type Time delay Net weight 55 lbs DUTY CYCLE This air compressor pump is capable of run...

Страница 9: ...each use F Check Valve not shown When the air compressor is operating the check valve is open allowing compressed air to enter the air tank When the air compressor reaches cut out pressure the check v...

Страница 10: ...ronment may cause damage to the unit NOTE Long lengths of electrical wiring could cause power loss to the motor Place the air compressor in a clean dry and well ventilated area The air compressor must...

Страница 11: ...sufficient to inflict serious injury WARNING Always wear safety goggles or safety glasses with side shields when operating power tools Failure to do so could result in objects being thrown into your e...

Страница 12: ...lting Inflator Brad Nailer Stapler Framing Roofing Nailer Impact Wrench Heavy Duty 1 2 in and 3 4 in Impact Wrench Air Ratchet Recommended Tool Use Tool Cutting Drilling Surface Prep Painting HVLP Pai...

Страница 13: ...ssure must never exceed the maximum pressure rating CAUTION Risk of unsafe operation Compressed air from the unit may contain wa ter condensation and oil mist Do not spray un fil tered air at an item...

Страница 14: ...to heed this warning could result in death or serious personal injury The safety valve automatically releases air when the receiver pressure exceeds the preset maximum Check the valve before each day...

Страница 15: ...injury NOTE Always use the minimum amount of air flow with the pressure regulator knob Using a higher pressure than needed will drain air from the tank more rapidly and cause the unit to cycle on mor...

Страница 16: ...oolers dryers This condensate contains lubricating oil and or substances which may be regulated and must be disposed of in accordance with local state and federal laws and regulations NOTE If the drai...

Страница 17: ...er 2 from the air filter housing 3 Blow compressed air through the air filter for 10 15 seconds using an approved OSHA nozzle 1 2 3 WARNING When servicing use only identical Industrial Air Contractor...

Страница 18: ...ntil the compressor restarts automatically The motor hums while running slowly or it does not run at all There is low voltage from the power source Call an electrician The wrong gauge wire or length o...

Страница 19: ...ution and tighten The drain valve is loose or open Tighten the drain valve The check valve is leaking Bring the compressor to a service center There is excessive moisture in the discharge air There is...

Страница 20: ...20 Service Parts C041I AIR COMPRESSOR 2 22 23 24 25 26 27 28 29 0 5 21 30 31 32 33 34 35 35 36 37 37 37 38 38 39 40...

Страница 21: ...Cord E106629 11 Filter Assembly E106632 12 Shroud Left E109737 13 Shroud Right E109317 14 Rocker Switch E106633 15 Pump E109720 16 Drain Valve E109739 17 Gauge Tank E107854 18 Gauge Regulator E107855...

Страница 22: ...older E109472 37 Screw 250 20 X 75 E106611 38 Screw 10 24 X 563 E106614 39 Screw 10 14 T20 E106646 40 Tank Top Panel E109742 41 Label Warning E109741 42 Label Warning Drain Tank E109313 43 Label Hot S...

Страница 23: ...ervice Parts continued PUMP MOTOR ASSEMBLY Item Number Description Part Number 1 Pulley E106663 2 Belt E106664 3 Fan E106665 4 Screw E106666 5 Flywheel E106667 6 Screw E106668 7 Screw kit of 4 E106669...

Страница 24: ...issing parts Before returning to the store call Customer Service 8 a m 6 p m EST Monday Friday PRODUCT SERVICE 888 895 4549 industrialaircontractor com Retain this manual for future use Document Numbe...

Отзывы: