page 1 / 9
document no.: X1-25_4.pdf
NDT Film Processors type:
produced by Colenta
To be used to process all standard
NDT Films
.
PRE-INSTALLATION MANUAL
NDT FILM PROCESSOR
01/2013 TK
Industrex M43ic
Страница 1: ...page 1 9 document no X1 25_4 pdf NDT Film Processors type produced by Colenta To be used to process all standard NDT Films PRE INSTALLATIONMANUAL NDT FILM PROCESSOR 01 2013 TK Industrex M43ic ...
Страница 2: ...loor or wall drain may be used which should include an anti syphon system Note Do not use brass or copper in the drain lines The minimum diameter of the drain lines should be 40 mm Electrical For operation a seperate 16 Amp fused socket with earth leakage protection is required for further information consult the processor datasheet Replenishment Each replenisher storage tank has a 30 litre capaci...
Страница 3: ...n the fumes are flowing out the PROCESSOR through the EXHAUST HOSE If the ventilation is to be connected to the PROCESSOR measure negative static pressure in the EXHAUST DUCT See on the page x Plumbing Requirements All plumbing requirements must comply with local and national codes Do not use IRON PIPES All DRAIN material must be made of chemically resistant non corrosive material Use PVC or the e...
Страница 4: ...ocument no X1 25_4 pdf DEV FIX 3 4 Watersupply Drain DEV FIX 2x30L Replenishment containers are supplied with the processor Water Supply Drain connection and Replenishment Exhaust port see more on page 6 OPTIONAL ...
Страница 5: ...3 2 90 45 001 Kugelhahn 3 4 In Line Tap 3 3 90 45 002 Doppelnippel 3 4 3 4in straight fitting 8 4 90 45 003 T Stück 3 4 T Fitting 3 4in 1 5 90 45 004 Bogen 3 4 90 3 4in Elbow 90 2 6 90 45 005 Reduzierung Male Female fitting 2 7 90 45 007 Holländer Filter inlet outlet fitting 2 8 90 45 009 Dichtung Flat washer 2 9 90 45 027 Filtergehäuse Fiter Housing 1 10 90 45 035 Filterpatrone Filter Cartridge 1...
Страница 6: ...r Air Meter can then be inserted through the opening When measuring negative air the tube tip opening should be pointed in the direction of airflow away from the processor The processor must be de energized when making air measurements The air meter should be held in the vertical position to assure the greatest accuracy The meter tubing must not be kinked It is most important that negative airflow...
Страница 7: ...page 7 9 document no X1 25_4 pdf recommended Installation Free standing Dark Stop cock 50cm Positive Air Pressure ...
Страница 8: ...page 8 9 document no X1 25_4 pdf recommended Installation Processor Darkroom Exit to light Dark Daylight Stop cock 50cm Positive Air Pressure ...