User Guide - v1-Draft 1
22
Click
Save
to apply any changes you have made.
Click
Cancel
to cancel the changes you have made to active periods.
•
Anti-dither
— Enter a time in seconds of
0
to
600
, in which the encoder will only
recognize a single detection.
•
Type
— Select the binary input type from
NO
(Normally Open) or
NC
(Normally
Closed).
•
Alarm out
— Select the checkbox to enable an Alarm upon detection, and click
Set
to
select the required Alarm output to be activated.
•
Latch
— Enter a time in seconds of
0
to
300
to latch the Alarm output following an
activation.
•
PTZ Activation
— Select the checkbox to enable a PTZ Activation upon detection,
and click
Set
to specify the PTZ presets to be sent for each Channel.
•
Snapshot
— Select the checkbox to enable, and select the buttons for camera
Snapshots to be taken on the selected Channels upon detection.
•
Send Email
— Select the checkbox to send an email to the configured email address
upon detection.
•
Buzzer
— Select the checkbox to enable a sound from the buzzer upon detection.
•
Log
— Select the checkbox to enable logging of each detection.
Click
Copy
and select a destination from the popup to copy all settings to the selected
Channel.
Click
Refresh
to undo the changes you have made in this page.
Click
Default
to restore all fields in the page to their default settings.
Click
Save
to apply any changes you have made.
Abnormality
Use this page to configure the detection of Abnormal events on the BX 8/16 Channel
Encoder.
On the
Network
and
User
tabs, you can setup actions to be taken when abnormal network
and user-level events are detected by the encoder.
•
Event type
— Select the type of Event for configuration from the drop-down.
•
Enable
— Select the checkbox to enable an Alarm upon detection of the selected
Event type.
•
Attempt(s)
— Enter the number of (unsuccessful) attempts after which the User will
be locked out (User only).
•
Lock Time
— Enter the time for which the User will be locked out after the number of
unsuccessful attempts (User only).
•
Alarm out
— Select the checkbox to enable an Alarm upon detection, and click
Set
to
select the required Alarm output to be activated.
•
Latch
— Enter a time in seconds of
0
to
300
to latch the Alarm output following an
activation.
•
Show Message
— Select the checkbox to display a pop-up error message for network
conflict event types (Network only).
•
Send Email
— Select the checkbox to send an email to the configured email address
upon detection.
•
Buzzer
— Select the checkbox to enable a sound from the buzzer upon detection.
•
Log
— Select the checkbox to enable logging of each detection.
Click
Refresh
to undo the changes you have made in this page.