17
User Guide - v1-Draft 1
For most cameras, the BX 8/16 Channel Encoder automatically detects the signal input type
(
AUTO
). If difficulties are encountered and the encoder cannot detect the input type, you can
configure this manually.
Select the signal input type for each Channel using the checkbox grid, or alternatively use the
checkbox at the top of each column to select that input type for all Channels:
•
AUTO
•
CVI
•
AHD
•
CVBS
•
OTHER
Click
Refresh
to undo the changes you have made in this page.
Click
Default
to restore all fields in the page to their default settings.
Click
Save
to apply any changes you have made.
Network
These pages allow you to configure the Network settings for the BX 8/16 Channel Encoder.
TCP/IP
Use this page to configure the TCP/IP settings for the BX 8/16 Channel Encoder.
•
Default Card
— Select a network card from the drop-down.
•
IP Version
— Select an IP version from the drop-down.
•
MAC Address
— Enter the Media Access Control address for the BX 8/16 Channel
Encoder.
•
IP Address
— Enter the IP Address.
•
Subnet Mask
— Enter the Subnet Mask.
•
Default Gateway
— Enter the Default Gateway.
•
Preferred DNS
— Enter the preferred domain name server.
•
Alternate DNS
— Enter an alternate domain name server.
•
MTU
— Enter the maximum transmission unit. This is the maximum size of a packet
which is sent from the BX 8/16 Channel Encoder.
Click
Refresh
to undo the changes you have made in this page.
Click
Default
to restore all fields in the page to their default settings.
Click
Save
to apply any changes you have made.
Connection
Use this page to configure the connection settings for the BX 8/16 Channel Encoder.
•
Max Connection
— Enter the maximum number of connections from the BX 8/16
Channel Encoder to the server. This cannot be more than 128.
Assign a connection port for the BX 8/16 Channel Encoder:
•
TCP Port
•
UDP Port
•
HTTP Port
•
HTTPS Port
5 Web configuration pages