- Clean cooling lubricant outlet on clamping cylinder
Orientation
During machining, the cooling flow flushes small chips through the spindle in the
direction of the clamping cylinder. Therefore, the cooling lubricant outlet on the
clamping cylinder must be cleaned at regular intervals.
Procedure
1. Disassemble the machine enclosure in the area ofthe spindles.
2. If necessary, remove the acrylic glass cover on the cooling lubricant collection
bin.
3.
Example: Cooling lubricant outlet B400
Clean cooling lubricant collection bin. Check that the cooling lubricant outlet X
is free of chips or other debris.
4. Reinstall the acrylic glass cover, if applicable.
Maintenance Summary - Care activities
20
Maintenance Instructions
G200.2
DIE078EN - 05.06.2019