background image

7

ELECTRICAL CONNECTION

 WARNING

•  Disconnect the appliance from the power supply.

• 

Installation must be carried out by qualified personnel who know the current safety and installation regulations.

•  The manufacturer declines all liability for injury to persons or animals and for damage to property resulting from 

failure to observe the regulations provided in this chapter.

•  The power cable must be long enough to allow the hob to be removed from the worktop.

• 

Make sure the voltage specified on the dataplate located on the bottom of the appliance is the same as that of 

the home.

CONNECTION TO THE TERMINAL BLOCK

For the electrical connection, use an H05RR-F or H05V2V2-F cable as specified in the table below.

Wires

Number x size

220-240V ~ +

380-415V 2N~ +

220-240V 3~ +

380-415V 3N~ +

3 x 4 mm2

4 x 1,5 mm2

5 x 1,5 mm2

4 x 1,5 mm2

C

B

A

      

230 

V

230 

V

230 

V

230 

V

230 

V

230 

V

230 

V

230 

V

230 

V

230 

V

230 

V

220-240 V ~ (AU and UK)

220-240 V 3~

(Belgium only)

380-415 V 2N~

220-240 V ~

380-415 V 3N~

380-415 V 2N~ 

(Holland only)

Important:

• 

Based on the wiring diagram (see figure) either keep or remove the metal jumpers between the screws 

on the terminal block L1-L2 and N1-N2.

•  If the cable is provided, see the connection instructions attached to the cable.

•  Make sure all six screws on the terminal block are tightened after connecting the cables.

Example of jumper present (left) or removed (right). See the wiring diagram for details (the jumpers can 

be between L1-L2 and between N1-N2).

Connect the yellow/green earth wire to the terminal with the symbol  .

This wire must be longer than the other wires.

1.  Remove the terminal block cover (A), undoing the screw and inserting the cover in the terminal block hinge (B).

2.  Insert the power cable in the cable clamp and connect the wires to the terminal block as indicated in the connection diagram located near it.

3.  Secure the power cable with the cable clamp.

4.  Close the cover (C) and screw it on the terminal block with the previously removed screw.

Each time the power is connected, the hob performs an automatic check for a few seconds.

If the hob already has a power cable, follow the instructions attached to the cable. Connect the appliance to the power supply by means of a multipole switch 

with minimum contact gap of 3mm.

Содержание VIA320XSC

Страница 1: ...ding the environment 5 Declaration of conformity 6 Before use 6 Existing pots and pans 6 Recommended pot bottom widths 6 Installation 6 Electrical connection 7 Instructions for use 8 Cleaning 9 Troubl...

Страница 2: ...2 145mm 180mm 210 mm 180mm 210 mm 145mm 180mm EN AVAILABLE HOB CONFIGURATION...

Страница 3: ...m min 50 mm 770 mm 325 mm 350 mm 743 mm R min 6 5 mm max 8 mm min 50 mm 51 mm 1 0 275 mm 2 0 330 mm 2 0 52 mm 1 0 R min 6 5 mm max 8 mm 750 mm 2 0 490 mm 2 0 380 mm 510 mm 484 mm 342 mm min 50 mm 51 m...

Страница 4: ...4 1 Min 5 mm Min 10 cm 2 3 5 mm min 20 mm min 40 mm Min 3 cm Max 6 cm Min 5 mm X 4...

Страница 5: ...en given instructions on safe appliance use and if they understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without s...

Страница 6: ...8 cm max 10cmmin 14 5cmmax INSTALLATION After unpacking the product check for any damage during transport In case of problems contact the dealer or the After Sales Service For built in dimensions and...

Страница 7: ...n the wiring diagram see figure either keep or remove the metal jumpers between the screws on the terminal block L1 L2 and N1 N2 If the cable is provided see the connection instructions attached to th...

Страница 8: ...ctivate the control lock repeat the activation procedure The luminous dot goes off and the hob is active again The presence of water liquid spilled from pots or any objects resting on the button below...

Страница 9: ...o high Wait for the hob to cool down before using it again F42 or F43 The connection voltage is wrong The sensor detects a discrepancy between the appliance voltage and that of the mains supply Discon...

Страница 10: ...ta 3 4 Cooking simmering thickening creaming Ideal for long cooking recipes rice sauces roasts fish with liquids e g water wines broth milk creaming pasta 2 3 Ideal for long cooking recipes less than...

Отзывы: