background image

GB

2

!

 Before operating your new appliance please read this

instruction booklet carefully. It contains important information
for safe use, installation and care of the appliance.

!

 Please keep these operating instructions for future

reference. Pass them on to possible new owners of the
appliance.

Positioning

!

 Keep packaging material out of the reach of children. It

can become a choking or suffocation hazard (

see

Precautions and tips

).

!

 The appliance must be installed by a qualified professional

according to the instructions provided. Incorrect installation
may cause harm to people and animals or may damage
property.

!

 This unit may be installed and used only in permanently

ventilated rooms in accordance with British Standard Codes
Of Practice: B.S. 6172 / B.S. 5440, Par. 2 and B.S. 6891
Current Editions. The following requirements must be
observed:

• The room must be equipped with an air extraction system

that expels any combustion fumes. This may consist of a
hood or an electric fan that automatically starts each time
the appliance is switched on.

• The room must also allow proper air circulation, as air is

needed for combustion to occur normally. The flow of air
must not be less than 2 m

3

/h per kW of installed power.

The air circulation system may
take air directly from the outside
by means of a pipe with an inner
cross section of  at least 100 cm

2

;

the opening must not be
vulnerable to any type of
blockages.

The system can also provide the
air needed for combustion
indirectly, i.e. from adjacent rooms
fitted with air circulation tubes as
described above. However, these
rooms must not be communal
rooms, bedrooms or rooms that
may present a fire hazard.

• Liquid petroleum gas sinks to the floor as it is heavier

than air. Therefore, rooms containing LPG cylinders must

also be equipped with vents to allow gas to escape in the
event of a leak. As a result LPG cylinders, whether
partially or completely full, must not be installed or stored
in rooms or storage areas that are below ground level
(cellars, etc.). It is advisable to keep only the cylinder
being used in the room, positioned so that it is not
subject to heat produced by external sources (ovens,
fireplaces, stoves, etc. ) which could raise the
temperature of the cylinder above 50°C.

Fitting the appliance

Gas and mixed hobs are manufactured with type X degree
protection against overheating. The following precautions
must be taken when installing the hob:

• Kitchen cabinets adjacent to the appliance and taller

than the top of the hob must be at least 600 mm from the
edge of the hob.

• Hoods must be installed according to their relative

installation instruction manuals and at a minimum
distance of 650 mm from the hob.

• Place the wall cabinets adjacent to the hood at a

minimum height of 420 mm from the hob (

see figure

).

If the hob is installed beneath a
wall cabinet, the latter must be
situated at a minimum of 700 mm
above the hob (

see figure

).

• The installation cavity should have the dimensions

indicated in the figure.

Fastening hooks are provided, allowing you to fasten the

hob to tops that are between 20 and 40 mm thick. To
ensure the hob is securely fastened to the top, we
recommend you use all the hooks provided.

555 mm

55 mm

475 mm

Hook fastening diagram

Hooking position

Hooking position

for top

 H=20 mm

for top 

H=30 mm

Installation

Enlarging the ventilation slot
between window and floor.

Adjacent
Room

Room to be
Vented

A

Examples of ventilation holes
for comburant air.

In a chimney stack or branched flue. 
(exclusively for cooking appliances)

Directly to 
the Outside

600mm min.

600mm min.

700mm min.

Содержание PC 640 T X/HA

Страница 1: ...Burner and nozzle specifications Description of the appliance 6 Overall view Start up and use 7 Practical advice on using the burners Precautions and tips 8 General safety Disposal Maintenance and car...

Страница 2: ...o the floor as it is heavier than air Therefore rooms containing LPG cylinders must also be equipped with vents to allow gas to escape in the event of a leak As a result LPG cylinders whether partiall...

Страница 3: ...st not come into contact with surfaces with temperatures higher than 50 C The installer must ensure that the correct electrical connection has been made and that it is compliant with safety regulation...

Страница 4: ...are available from any of our Service Centres Replacing the Triple ring burner nozzles 1 Remove the pan supports and lift the burners out of their housing The burner consists of two separate parts se...

Страница 5: ...6 3 00 2 60 1 65 1 00 3 30 132 H 122 H 96 79 6 103x2 286 248 157 95 343 Burner and nozzle specifications At 15 C and 1013 mbar dry gas Propane P C S 50 37 MJ Kg Butane P C S 49 47 MJ Kg Natural P C S...

Страница 6: ...ose the most appropriate burner to cook with Control Knobs for GAS BURNERS adjust the size of the flame SAFETY DEVICES Ignition for GAS BURNERS Support Grid for COOKWARE Control Knobs for GAS BURNERS...

Страница 7: ...far as possible and turning it anticlockwise towards the maximum setting If a flame is accidentally extinguished turn off the control knob and wait for at least 1 minute before trying to relight it T...

Страница 8: ...tioning of the appliance Contact a Service Centre see Assistance Always make sure that pan handles are turned towards the centre of the hob in order to avoid accidental burns Do not close the glass co...

Страница 9: ...burners should be washed frequently with warm water and soap and any burnt on substances removed For hobs which ligth automatically the terminal part of the electronic instant lighting devices should...

Страница 10: ...liance You pressed the knob all the way in You keep the knob pressed in long enough to activate the safety device The gas holes are not blocked in the area corresponding to the safety device The gas h...

Страница 11: ...l r ve memelerin zellikleri Cihaz n tan t m 16 Genel g r n Cihaz n al t r lmas ve kullan lmas 17 Br l rlerin kullan m i in pratik tavsiyeler nlemler ve tavsiyeler 18 Genel emniyet mha Servis ve bak m...

Страница 12: ...hlikesi olan mek nlarda ya da yatak odalar nda olmamal d r S v la t r lm petrol gazlar havadan daha a r olduklar ndan a a ya do ru kerler Dolay s yla LPG t pleri bulunan mek nlarda d ar a lan bu pence...

Страница 13: ...r rl kteki normlara uygun nitelikte ok kutuplu bir anahtar takmak gerekmektedir toprak kablosu elektrik anahtar taraf ndan kesintiye u rat lmamal d r Besleme kablosu hi bir a amada ortam s s n 50 C g...

Страница 14: ...a n zgaralar n al n z ve br l rleri yuvalar ndan kart n z 2 7 mm lik bir boru anahtar kullanarak memeleri s k n z ve yeni gaz tipine uyarlanm olanlarla de i tiriniz bak n z tablo 1 Br l r ve memelerin...

Страница 15: ...6 103x2 286 248 157 95 343 15 C ve 1013 mbar da kuru gaz Propan P C S 50 37 MJ Kg B tan P C S 49 47 MJ Kg Do al P C S 37 78 MJ m Br l r ve memelerin zellikleri Model Gaz b l m S n f G kW II2H3 II2H3 P...

Страница 16: ...e sahiptir Kullanaca n z kab n ap na en uygun olan se iniz Alev ve g c n ayarlanmas i in GAZ BR L RLERI kumanda d meleri Gaz br l rleri AKMAKLARI se ilmi olan br l r n otomatik olarak yak lmas n sa la...

Страница 17: ...tutarak maksimum g pozisyonuna gelene kadar saat y n n n tersinde d nd r n z Br l r alevlerinin beklenmedik ekilde s nmesi durumunda kontrol d mesini kapat n z ve en az 1 dakika bekledikten sonra tek...

Страница 18: ...ya bak m m dahalelerinde bulunmay n z Ar za halinde onarmak amac yla i mekanizmalar kurcalamay n z Teknik servis ile irtibata ge iniz Teknik servis b l m ne bak n z Kazayla darbeye maruz kalmalar n nl...

Страница 19: ...muhtemel kire birikintilerinin z lmesine dikkat edilerek s cak su ve deterjanla s k s k y kanmal d r Otomatik ate lemeli set st ocaklarda elektronik an nda ate leme sisteminin terminal k sm s k s k ve...

Страница 20: ...k m olabilir Minimum ayar do ru yap lmam Kab n zemini d md z Kap br l r n ya da elektrikli levhan n tam ortas na oturtulmu Izgaralar n yerleri de i mi Ar zalar Br l r yanm yor veya alev d zenli de il...