The function terminates automatically after 255 seconds.
You can interrupt the autotest function by switching on the appliance by means of the freezer knob or by
disconnecting and reconnecting the mains power supply.
With regard to appliance loads driven by the PCB during the autotest procedure and the tested sensors,
any faults will be signalled by flashing of the fridge lamp.
Autotest for: Basis
E
lectronic Fridge Freezers.
E
lectronic Digit Fridge Freezers, Ba-
sic No Frost
E
lectronic Fridge Freezers.
Activation of the Autotest function for these appliances must be performed by executing the following proce-
dure:
1. Turn the Fridge knob to the minimum position (compartment OFF).
2. Turn the Freezer knob to the minimum position (appliance OFF).
3. Press the SUPER FREEZER button for approximately 5 seconds.
When the autotest procedure has been activated the 3 LEDs will illuminate steadily for approximately 5
seconds (if the digital interface is present the 2 digits will illuminate together with the LEDs).
The function terminates automatically after 255 seconds.
You can interrupt the autotest function by switching on the appliance by means of the freezer knob or by
disconnecting and reconnecting the mains power supply.
With regard to appliance loads driven by the PCB during the autotest procedure and the tested sensors,
any faults will be signalled by flashing of the fridge lamp.