16
GB
TECHNICAL DATA
Oven dimensions
(WxDxH)
39x41x34 cm
Volume
54 l
Useful
measurements
relating to the oven
compartment
width 42 cm
depth 44 cm
height 18 cm
Power supply
voltage and
frequency
see data plate
Electric hob
Front left
Back left
Back right
Front right
Maximum absorption
of the electric hob
1500 W
2000 W
1500 W
2000 W
7000 W
ENERGY LABEL
Directive 2002/40/EC on the
label of electric ovens. Standard
EN 50304
Declared energy consumption
for Natural convection Class –
heating mode:
Ventilated
EC Directives: 2006/95/EC
dated 12/12/06 (Low Voltage)
and subsequent amendments -
2004/108/EC dated 15/12/04
(Electromagnetic Compatibility)
and subsequent amendments -
93/68/EEC dated 22/07/93 and
subsequent amendments -
2002/96/EC.
1275/2008 (Stand-by/ Off mode)
Connecting the supply cable to the mains
Install a standardised plug corresponding to the
load indicated on the data plate located on the
appliance.
The appliance must be directly connected to the
mains using an omnipolar circuit-breaker with a
minimum contact opening of 3 mm installed between
the appliance and the mains. The circuit-breaker
must be suitable for the charge indicated and must
comply with current electrical regulations (the
earthing wire must not be interrupted by the circuit-
breaker). The supply cable must be positioned so
that it does not come into contact with temperatures
higher than 50°C at any point.
Before connecting the appliance to the power
supply, make sure that:
• The appliance is earthed and the plug is compliant
with the law.
• The socket can withstand the maximum power of
the appliance, which is indicated by the data
plate.
• The voltage is in the range between the values
indicated on the data plate.
• The socket is compatible with the plug of the
appliance. If the socket is incompatible with the
plug, ask an authorised technician to replace it.
Do not use extension cords or multiple sockets.
!
Once the appliance has been installed, the power
supply cable and the electrical socket must be
easily accessible.
!
The cable must not be bent or compressed.
!
The cable must be checked regularly and replaced
by authorised technicians only.
!
The manufacturer declines any liability should
these safety measures not be observed.
Содержание K3E 517
Страница 1: ...RS 1 2 3 4 5 6 9 10 11 12 K3E517 RU KN3E517 RU...
Страница 3: ...3 RS 90 C 200 420 700 200 1 V 2 230 1 2 3 4 5 3 N 4 1 2 3 5 6 V...
Страница 5: ...5 RS 5 4 3 2 1...
Страница 6: ...6 RS 1 2 0 1 0 1 2...
Страница 7: ...7 RS 50 Max Max 200 0 Multicooking 80 100 50 C Max 50 C Max gratin 80 60 0 50 C Max 50 C Max...
Страница 8: ...8 RS 3 4 1 4 50 50 C Max 1 5 2 4 2 4 220 15 4 4...
Страница 10: ...10 RS 6 0 1 2 5 6 0 1 2 3 4 5 6 4...
Страница 11: ...11 RS 1 2 1 0 2002 96 EC WEEE 10...
Страница 12: ...12 RS 1 2 230 25 14 3 S N...
Страница 13: ......