28 of 39
Service Manual UK
Indesit
Company
English
FAULT CODES
3/4
FAULT
SUBCODE
DESCRIPTION
CHECKS
F12
01
Communication- MAIN
1
Unplug, wait for 2 minutes, plug back in again and
test the appliance.
2
Reprogram the Main PCB.
3
Replace the Main PCB.
4
Replace the Display PCB.
02
Communication - VISUAL
03
C o m m u n i c a t i o n - N O
A L I G N M E N T W I T H M A I N
SETTING (ON BOARD SETTING
OK (CHKSUM OK))
04
C o m m u n i c a t i o n - N O
A L I G N M E N T W I T H M A I N
S ON BOARD SETTING
CORRUPTED (CHKSUM KO))
F13
01
F l o o r h e a t i n g e l e m e n t :
D I S C O N N E C T E D o r
INTERRUPTED / heating element
relay jammed / heating element
dispersing energy, master relay
jammed.
1
Check that the floor heating element is working
properly.
2
Check connectors on component and board sides.
3
Check the state of cables.
4
Replace the Main PCB.
F14
01
C i r c u l a r h e a t i n g e l e m e n t
D I S C O N N E C T E D o r
INTERRUPTED / heating element
relay jammed / heating element
dispersing energy, master relay
jammed.
1
Check that the circular heating element is working
properly.
2
Check connectors on component and board sides.
3
Check the state of cables.
4
Replace the Main PCB.
F16
01
S t e a m h e a t i n g e l e m e n t :
D I S C O N N E C T E D o r
INTERRUPTED / heating element
relay jammed / heating element
dispersing energy, master relay
jammed.
1
Check that the steam heating element is working
properly.
2
Check connectors on component and board sides.
3
Check the state of cables.
4
Replace the Main PCB.
F17
01
G r i l l 1 h e a t i n g e l e m e n t :
D I S C O N N E C T E D o r
INTERRUPTED / heating element
relay jammed / heating element
dispersing energy, master relay
jammed.
1
Check that the Grill 1 heating element is working
properly.
2
Check connectors on component and board sides.
3
Check the state of cables.
4
Replace the Main PCB.
F18
01
G r i l l 2 h e a t i n g e l e m e n t :
D I S C O N N E C T E D o r
INTERRUPTED / heating element
relay jammed / heating element
dispersing energy, master relay
jammed.
1
Check that the Grill 2 heating element is working
properly.
2
Check connectors on component and board sides.
3
Check the state of cables.
4
Replace the Main PCB.
F19
01
D i v i d e r h e a t i n g e l e m e n t :
D I S C O N N E C T E D o r
INTERRUPTED / heating element
relay jammed / heating element
dispersing energy, master relay
jammed.
1
Check that the divider heating element is working
properly.
2
Check connectors on component and board sides.
3
Check the state of cables.
4
Replace the Main PCB.
F20
01
C e i l i n g h e a t i n g e l e m e n t :
D I S C O N N E C T E D o r
INTERRUPTED / heating element
relay jammed / heating element
dispersing energy, master relay
jammed.
1
Check that the ceiling heating element is working
properly.
2
Check connectors on component and board sides.
3
Check the state of cables.
4
Replace the Main PCB.
F22
01
A heating element is dispersing
energy (not possible to indicate
which) or master relay jammed.
1
Check if any of the heating elements are dispersing
energy.
2
Replace the Main PCB.