25 of 39
Service Manual UK
Indesit
Company
English
AUTO-TEST
Start with the oven off and oven door closed.
Key '
+
', Key '
–
', Key '
+
'.
Press and hold the '
clock
' key for 5 seconds (a beep will sound to confirm the selection).
Press “
Start
” (a beep will sound to confirm the selection).
Load Activation Sequence:
1.
Indicator lamps light up for the duration of the Autotest sequence.
2.
Oven PTC probes and main NTC PCB checked.
3.
For 5 seconds: Tangential ON and door blocked (where there is a door lock).
4.
For 5 seconds: Tangential ON, spit roast ON (where present) and Door Lock released (where
present).
5.
For 15 seconds: Circular Heating Element ON, Motor Fan ON, Spit roast ON (where present).
6.
For 15 seconds: Grill Heating Element ON, Motor Fan ON, Spit roast ON (where present)
7.
END
NOTE: -
If there is a Last Fault, it will be displayed for the first 20 seconds before the autotest
sequence commences. If there is no Last Fault, the sequence will start immediately.