Electrical connection and working test
• Before connecting to the mains supply ensure that the mains voltage corresponds
with the voltage on the rating plate inside the hood.
• Connect the cooker hood to the mains via a double pole switch which has 3 mm
clearance between the contacts.
• The appliance must be earthed.
• Once the electrical connection has been completed, check that worktop illumination,
motor and speed work properly.
Fitting the telescopic chimney stack
•
Fit
the two plastic supports provided to the top part of the hood.
• To fit the upper section item
S
first expand the chimney slightly to allow it to fit over the
wall brackets (item
2 fig. 1
) and then secure the upper section using the 4 screws supplied.
• The lower section item
I
of the chimney stack should be fitted between the lower bracket
2
and the wall.
•
Fix
the U-shaped section to the plastic supports, using two of the screws provided in the
bag of accessories (
fig. 7
).