Electrical Connection
If your appliance is supplied with a 13 amp. fused plug
it can be plugged into a 13 amp socket for immediate
use. Before using the appliance please read the
instruction below.
WARNING: THIS APPLIANCE MUST BE
EARTHED.
THE FOLLOWING OPERATIONS SHOULD BE
CARRIED OUT BY A QUALIFIED ELECTRICIAN.
Replacing the fuse:
When replacing a faulty fuse, a 13 amp ASTA
approved fuse to BS 1362 should always be used, and
the fuse cover re-fitted. If the fuse cover is lost, the
plug must not be used until a replacement is obtained.
Replacemente fuse covers:
If a replacement fuse cover is fitted, it must be of the
correct colours as indicated by the coloured marking
or the colour that is embossed in words on the base of
the plug. Replacements can be obtained directly from
your nearest Service Depot.
Removing the plug:
Ifyour appliance has a non-rewireable moulded plug
and you should wish to remove it to re-route the mains
cable through partitions, units etc., please esure that
either:
- the plug is replaced by a fused 13 amp re-wireable
plug bearing the BSI mark of approval
- or:
- the mains cable is wired directly into a 13 amp cable
outlet, controlled by a switch, (in compliance with BS
5733) which is accessible without moving the
appliance.
Disposing of the plug:
Ensure that before disposing of the plug itself, you
make the pins unusable so that it cannot be
accidentally inserted into a socket.
Instruction for connecting cable to an altenative
plug:
Important: the wires in the mains lead are coloured
in accordance with the following code:
Green & Yellow
-
Earth
Blue
-
Neutral
Brown
-
Live
CAUTION:
- Once the appliance has been installed, the electrical plug
and socket should remain accessible.
- The Company shall not be held responsible for any
incidents that occur if these regulations are not observed.
As the colours of the wires in the mains lead may not
correspond with the coloured markings identifying the
terminal in your plug, proceed as follows:
connect Green & Yellow wire to terminal market
E
or
coloured Green or Green & Yellow.
Connect Brown wire to terminal marked
L
or
coloured Red.
Connect Blue wire to terminal marked
N
or coloured
Black.
If a 13 amp plug (BS 1363) is used it must be fitted with
a 13 amp fuse. A15 amp plug must be protected by a 15
amp fuse, either in the plug or adaptor or at the
distribution board.
If you are in any doubt about the electrical supply to
your machine, consult a qualified electrician before
use.
How to connect an alternative plug:
The wires in this mains lead are coloured in
accordance with the following code:
BLUE
NEUTRAL (N)
BROWN
LIVE (L)
GREEN AND YELLOW
EARTH (E)
or
Disposing of the appliance:
When disposing of the appliance please remove the
plug by cutting the mains cable as close as possible to
the plug body and dispose of it as described above.