background image

Qty.

NO. DESCRIPTION.

1.

2A.

2A.

2B.

2C.

3.

4.

5.

6.

7.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

22.

23.

24.

26.

27.

28.

29.

33.

1

1

1

4

1

1

1

2

1

6

2

1

2

1

1

1

1

1

1

1

4

1

1

1

1

1

1

1

1

CYLINDER

WATER TANK

STAND

BOLT

SUPPORT

PLUNGER

HANDLE

SUPPORT PIN

CENTER PIN

SNAP RING

PLUNGER O-RING P-22

SUCTION CASE

SUCTION & DELIVERY VALVE

SPRING

SUCTION O-RING P-14

STRAINER

VALVE JOINT

DELIVERY O-RING P-15

AIR GAUGESTAND

SPINDLE

BOLT

GREASE CAP

PRESSURE GAUGE

PRESSURE HOSE

GRIP

SUCTION VALVE

O-RING P-18

BUSHING

NAME PLATE

Page # 2- M:231C

PRESSURE TESTING PUMP

CONSTRUCTION

PRESSURE TESTING PUMP

FEATURES :

 

The Testing Pump is very compact, light in weight and can be unbolted to carry easily. 

Stand is designed in such a way to keep on plane surface and operate without any foundation. Even 
in Testing Pumps also no fixing or foundation is needed.  All the working parts are made of stainless 
steel & Fiber.  All the joints are threaded so that any part can be easily replaced even at site also.

Page # 1- M:231C

2

Prod.

No.

231C

 

Strock

Capacity of

Water Tank

Weight

Accessories

Memo

Plastic

Tank

35mm

13c.c.

5L

5 Kgs. Pressure Hose 1

Bushing 1/2x1/4 1.

Rate of Water Section

Per Stroke

Maximum

Pressure

6MPa

60kg/cm

Unit Conversion : 

1MPa = 10Bar = 10.1972kg/Cm²/ = 145.038Psi

1. Install the stop valves to the test pipe (#1,#2).
2. Fill up the test pipe with water by the use of service water or other 

supply source.

3. When the test pipe is filled with water, remove air and close the valve 

(#2).

4. Connect the tester and the test pipe with the attached pressure-resistant 

hose ass'y.

5. Fill the water tank of the tester with water and operate the pump.
6. Open the stop valve (#1) of the test pipe and continue the operation to 

fill up with water.

7. When the pressure gauge No.23 equipped to the tester rises to the 

required pressure, stop operate the pump.

8. If the pressure does not drop, the test pipe is perfect.
9. If the pressure drops, it is indicative of leakage caused somewhere on 

the test pipe.

TESTING PROCEDURES

Отзывы: