SNS20-28C Actuator with Internal Battery Back-up Installation, Operation & Maintenance Manual    

 

 

 

 

Page 2 

 

 

 

INTRODUCTION: 

Thank  you  for  selecting  Indelac  Controls,  Inc.  (

ICI

)  for  your  valve  or  damper  automation 

requirement.  We  at 

ICI

  are  proud  of  our  products  and  feel  confident  they  will  meet  or 

exceed your expectations of quality and reliability. 
Every  precaution  has  been  taken  to  insure  that  your  equipment  will  arrive  undamaged; 

however, accidents do occur.  Therefore, the first thing you must do upon receipt of your 

package is to inspect it for damage.  If the box is damaged there is a possibility that the 

equipment inside the box may be damaged as well.  If this is the case 

YOU MUST FILE A 

CLAIM

 with the delivering 

CARRIER

.  All shipments are 

F.O.B.

 our factory and it is 

YOUR 

RESPONSIBILITY

 to file a claim for damages. 

STORAGE: 

If the actuators are scheduled for installation at a later date: 

1. 

Store off the floor. 

2. 

Store in a climate controlled building. 

3. 

Store in a clean and dry area. 

FOR FUTURE REFERENCE RECORD: 

1. 

Actuator model number 

 

 

 

 

 

 

 

 

 

2. 

Actuator enclosure type NEMA 4  , NEMA 4X _, NEMA 7 _, NEMA 4 & 7__ 

3. 

Actuator output torque  

 

LB-IN 

4. 

Motor characteristics, Voltage 

 

Hertz  

 

Phase 

 

 

5. 

Actuator serial number  

 

 

 

 

 

 

 

 

 

6. 

Date of installation 

 

 

 

  

Put into operation 

 

 

7. 

Valve Data: 

 

7a.  Manufacturer 

 

 

 

 

 

 

 

 

 

 

 

7b.  Style & fig. No.   

 

 

 

 

 

 

 

 

 

 

7c.  Size   

 

 

 

 

 

 

 

 

 

 

 

 

7d.  End connection   

 

 

 

 

 

 

 

 

 

 

7e.  Material of construction, Body 

 

 

 

Stem & ball  

 

 

7f.  Brake away torque 

 

 

 

   LB-IN @   

 

PSI 

 

7g.  Other helpful data 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MEDIA: 

1. 

System media   

 

 

 

 

 

 

 

 

 

 

2. 

Temperature, 

 

(deg. F.) Maximum,   

. Minimum,  

3. 

Pressure   

 

PSI 

 

*As  this  information  is  listed  it  is  important  to  pay  attention  to  all  of  the  actuator  specifications 

relative to the valve specifications and system requirements.  If the actuator is not properly sized 

for the valve and application the life will be shortened or it may not work at all. 

 
 

Содержание SNS20

Страница 1: ...including but not limited to models with modulating controls timers speed controllers remote off local controls TELEPHONE 1 859 727 7890 TOLL FREE 1 800 662 9424 FAX 1 859 727 4070 SHIPPING ADDRESS 68...

Страница 2: ...Y to file a claim for damages STORAGE If the actuators are scheduled for installation at a later date 1 Store off the floor 2 Store in a climate controlled building 3 Store in a clean and dry area FOR...

Страница 3: ...t Terminal Strip Screws 3 16 Wide Flat Head Screwdriver Cam Set Screw 5 64 Allen Wrench Mounting Pad Screws 9 16 Socket SUGGESTED MAXIMUM TORQUE VALUES FOR FASTENERS IN LBS SCREW SIZE LOW CARBON STEEL...

Страница 4: ...external power and the battery will begin to re charge automatically The actuator will then return to its last position before the power had failed This unit is available as a Standard OPEN CLOSE Actu...

Страница 5: ...Operation Maintenance Manual Page 5 MECHANICAL MOUNTING The Safe Secure Actuator can be direct mounted to any valve using the standard ISO 5211 F10 Output See the drawing below for the actuator outpu...

Страница 6: ...your local electrical codes Remove the actuator cover by loosening the cover screws and pulling straight up on the cover to complete the wiring and set up Connect the Main Power to the actuator per t...

Страница 7: ...IONS FOR STANDARD OPEN CLOSE WIRING DIAGRAM W200628 200628 DESCRIPTION 24VAC 24VDC SNS2000 ACTUATOR STANDARD OPEN CLOSE OPTIONS SHOWN OPTIONS SHOWN OPTIONS SHOWN 2 AUXILIARY SWITCHES MOTOR BRAKE HEATE...

Страница 8: ...OR STANDARD OPEN CLOSE WIRING DIAGRAM W200707 200707 DESCRIPTION 12VDC SNS2000 ACTUATOR STANDARD OPEN CLOSE OPTIONS SHOWN OPTIONS SHOWN OPTIONS SHOWN 2 AUXILIARY SWITCHES MOTOR BRAKE HEATER AND THERMO...

Страница 9: ...tion Maintenance Manual Page 9 CUSTOMER ELECTRICAL CONNECTIONS FOR MODULATING OPTION WIRING DIAGRAM W200620 200620 DESCRIPTION 115 230VAC ACTUATOR WITH MODULATING CONTROL OPTIONS SHOWN OPTIONS SHOWN O...

Страница 10: ...ion Maintenance Manual Page 10 CUSTOMER ELECTRICAL CONNECTIONS FOR MODULATING OPTION WIRING DIAGRAM W200629 200629 DESCRIPTION 24VAC 24VDC ACTUATOR WITH MODULATING CONTROL OPTIONS SHOWN OPTIONS SHOWN...

Страница 11: ...eration Maintenance Manual Page 11 CUSTOMER ELECTRICAL CONNECTIONS FOR MODULATING OPTION WIRING DIAGRAM W200630 630 DESCRIPTION 12VDC ACTUATOR WITH MODULATING CONTROL OPTIONS SHOWN OPTIONS SHOWN OPTIO...

Страница 12: ...ACTUATOR WILL MOVE TO THE OPEN POSITION WHEN POWER FAILS CLOSE ACTUATOR WILL MOVE TO THE CLOSE POSITION WHEN POWER FAILS WARNING DO NOT switch the FAIL switch while the actuator is moving or while the...

Страница 13: ...the valve is opening and closing fully If not the Open and Close CAMs may be adjusted to allow more or less motion in both directions The CAM set screw needs to be loosened to rotate the CAM Re tighte...

Страница 14: ...fails the battery will supply power to the Controller Board and run the motor to the selected FAIL position 2 Set the DIP Switch 3 to ON right 4 to OFF left on the DMC 102 Controller Board This will...

Страница 15: ...Secure Board should illuminate indicating that the power from the external source is on When the external power fails the Blue LED will turn off and the Yellow Battery LED will illuminate indicating...

Страница 16: ...the Modulating SNS Board There is a battery charge circuit built into the Safe Secure actuator that will charge the battery when the external power is on After a full 8 10 hour full charge the Green b...

Страница 17: ...eck the entire system and clear any jams or valve binding prior to restarting the system MECHANICAL OVER LOAD Indelac actuators are all designed to withstand stall conditions It is not recommended to...

Страница 18: ...ors rated NEMA 4 and 7 take care that the gasket is in place to assure the proper clearance after the cover is secured After securing the cover screws check the clearance between the cover and the bas...

Страница 19: ...minal block screws Bad Brake Remove brake hub try to run Modulating Signal Not Present Connect 4 20mA or 0 10vdc Signal to Actuator ACTUATOR WILL NOT OPEN OR CLOSE COMPLETELY Travel limits set wrong R...

Страница 20: ...e the Test Switch again 10 If the Battery Green LED on the Safe and Secure Board illuminates the battery is good and is charged 11 If the Red LED is comes back on or is OFF the battery is bad and need...

Страница 21: ..._____________________________________________________ _________________________________________________________________ _________________________________________________________________ ______________...

Страница 22: ..._____________________________________________________ _________________________________________________________________ _________________________________________________________________ ______________...

Страница 23: ..._____________________________________________________ _________________________________________________________________ _________________________________________________________________ ______________...

Страница 24: ...nce Manual Page 24 Contact Information Debbie Voges dvoges indelac com 859 727 7890 ext 100 Matt Robinson mrobinson indelac com 859 727 7890 ext 109 Talbot Caywood tcaywood indelac com 859 727 7890 ex...

Отзывы: