![Indel Webasto Isotherm Cruise Classic Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/indel-webasto/isotherm-cruise-classic/isotherm-cruise-classic_installation-and-usage-instructions_2051444029.webp)
User Manual
56
7 LEDs for diagnostics
The electronic control unit has a troubleshooting function when a LED is connected
as shown below.
The number of flashes indicates the type of error.
Number of LED
Flashes
Type of Error
Solution
6
Defective sensor (the sensor is defec
-
tive or disconnected).
Re-connect the sensor and verify that
the compressor starts working again.
Replace sensor if the compressor does
not work.
5
Thermal protection of the electronic
control unit
.
(the electronic control unit overheats
if the refrigeration system has become
overloaded or the environmental tem
-
perature is too high)
Remove excess gas or increase ventila
-
tion.
4
Minimum motor speed error.
(if the refrigeration system has been
overloaded, the motor cannot maintain
minimum speed of approximately
1.850 RPM).
Remove excess gas.
3
Motor starting error
[the rotor is blocked or pressure inside
the refrigerant circuit is too high (> 5
bar)].
Defective electronic control unit.
The first operation to attempt is to
replace the electronic control unit. Re-
place compressor if problem persists.
2
Fan short-circuited
(the fan absorbs more than 1A from
the electronic control unit).
Replace the fan.
1
Battery protection
(voltage is outside the maximum and
minimum voltages).
Check power cable conditions. Replace
with new cables if necessary. Check
battery conditions.
Содержание Isotherm Cruise Classic
Страница 2: ...3 Isotherm Cruise Serie Fig 1 Fig 2...
Страница 3: ...4 Isotherm Cruise Serie Fig 3 Fig 4...
Страница 4: ...5 Isotherm Cruise Serie Fig 5 Fig 6...
Страница 5: ...6 Isotherm Cruise Serie Fig 7 Fig 8...
Страница 6: ...7 Isotherm Cruise Serie Fig 9 Fig 10...
Страница 7: ...8 Isotherm Cruise Serie Fig 11 Fig 12...
Страница 34: ...245 Isotherm Cruise Standard Cruise DC 12 24 Volt...
Страница 35: ...246 Isotherm Cruise Standard Cruise AC DC 12 24 Volt 100 240 Volt...
Страница 36: ...247 Isotherm Cruise Cruise CR130 DRINK DC 12 24 Volt...
Страница 37: ...248 Isotherm Cruise Cruise CR130 DRINK AC DC 12 24 Volt 100 240 Volt...
Страница 38: ...249 Isotherm Cruise Cruise CR42C DC 12 24 Volt...
Страница 39: ...250 Isotherm Cruise Cruise CR42C AC DC 12 24 Volt 100 240 Volt...
Страница 40: ...251 Isotherm Cruise Cruise CR160 DC 12 24 Volt...
Страница 41: ...252 Isotherm Cruise Cruise CR160 AC DC 12 24 Volt 100 240 Volt...