6 Troubleshooting
All work on electrical parts or electrical connections and the refrigerant circuit must
be carried out by qualified and authorised personnel.
Warning: Disconnect electrical power before performing any operations on electrical
parts or on electrical connections.
Defect
Possible cause
Intervention
The refrigerator does not
cool, the compressor will
not start.
No electrical power. Battery
in poor conditions. Faulty
thermostat. Defective
electronic control unit.
Check to make sure that the electronic
control unit is receiving sufficient power
and voltage; check the fuse. Verify that the
internal lighting is working and that the
compressor is receiving power. Check the
cables, lugs and connectors. Verify that
the battery is charging properly. Check the
thermostat: Bridge T - C with a separate
cable. If the compressor will not start,
its electronics are probably defective.
Replace. If the compressor starts up with
the bridge, the thermostat is defective.
Replace the thermostat.
The compressor only
performs brief attempts at
starting up.
There is insufficient voltage or
else a drop in voltage during
the attempt to start. The
protection device is activated.
The Batteries are drained.
Check the cables and connections; remove
any traces of oxidation or corrosion.
Charge the batteries, start the motor or
connect the battery charger.
The compressor functions
but doesn’t cool.
Loss of refrigerant through
the evaporator or the tubing.
Tubing clogged.
Carry out a leak check and repair any
leaks, drain and refill the proper amount of
R134a refrigerant. (This operation must be
carried out by a qualified technician.)
The compressor runs for
a long time but doesn’t
cool properly (reduced
efficiency).
Insufficient ventilation,
the condensation unit is
overheating. The fan is not
working properly. There is too
much frost on the evaporator.
The door does not close
properly and lets in warm,
moist air. The condenser is
blocked by dust.
Increase the ventilation. Replace the fan.
Defrost the unit. Correct the position of
the door and check the gasket. Clean the
condensing unit.
Содержание Isotherm Cruise Classic
Страница 2: ...3 Isotherm Cruise Serie Fig 1 Fig 2...
Страница 3: ...4 Isotherm Cruise Serie Fig 3 Fig 4...
Страница 4: ...5 Isotherm Cruise Serie Fig 5 Fig 6...
Страница 5: ...6 Isotherm Cruise Serie Fig 7 Fig 8...
Страница 6: ...7 Isotherm Cruise Serie Fig 9 Fig 10...
Страница 7: ...8 Isotherm Cruise Serie Fig 11 Fig 12...
Страница 34: ...245 Isotherm Cruise Standard Cruise DC 12 24 Volt...
Страница 35: ...246 Isotherm Cruise Standard Cruise AC DC 12 24 Volt 100 240 Volt...
Страница 36: ...247 Isotherm Cruise Cruise CR130 DRINK DC 12 24 Volt...
Страница 37: ...248 Isotherm Cruise Cruise CR130 DRINK AC DC 12 24 Volt 100 240 Volt...
Страница 38: ...249 Isotherm Cruise Cruise CR42C DC 12 24 Volt...
Страница 39: ...250 Isotherm Cruise Cruise CR42C AC DC 12 24 Volt 100 240 Volt...
Страница 40: ...251 Isotherm Cruise Cruise CR160 DC 12 24 Volt...
Страница 41: ...252 Isotherm Cruise Cruise CR160 AC DC 12 24 Volt 100 240 Volt...