background image

1. Locating the tank

The water heater can be mounted anywhere on the 
vessel as long as the connections to the engine heat 
exchanger are below the engine header tank (Fig. 
1). It is best to keep the length of the heat exchanger 

hoses short to keep fl ow resistance and heat loss to a 
minimum. In many installations the tank heat exchanger 
is  simply connected inseries with the engine coolant 
circuit. In some installations it is connected in parallel 
with a fl ow restrictor/diverter.

Principal connection diagram

Engine coolant

Coolant
return

Water tap mixer

Electrical freshwater 
pressure pump

Freshwater tank

Safety valve /
drain valve

Cold water in

Hot water out

2. Mounting

The Isotemp Basic, Slim & Slim Square water heaters 
are designed to give excellent performance when 
mounted horizontally and vertically. The drain / safety 
valve must always be at the lowest point. The mounting 
brackets can be adjusted to the side on Basic and Slim 
for mounting the tank on a bulkhead. Always mount the 
tank to a suitable shelf or bulkhead and 

keep in mind 

the extra weight of the tank when it is full of water.

Fig. 1

000835-3

The choice depends on the specifi c recommendations 
of the engine manufacturer and or installer. Please 
consult the manufacturer or dealer of your engine for 
any recommendations they may have for connecting to 
the engine cooling system.
In case the tank has to be placed above the engine 
header tank, the engine water hose circuit must be 
equipped with an air bleeder valve on the highest point. 
This is available as an extra equipment. 

See alternative mounting positions fi g. 2.
Slim Square can be standing or laying down fl at, or 
placed in other alternative positions as seen in fi g. 7.
Fig. 3 shows Basic, fi g. 4 Basic with double coils, fi g. 5 
Slim and fi g. 6 Slim Square water hose connections.
It is to prefer to keep about 30 cm (1 ft.) free space in 
front of the water heater for future service measures. 

pantherRVproducts.com

Содержание 602421B000003

Страница 1: ...l Zona Artigianale sn IT 61019 S Agata Feltria PU Italy Tel 39 0541 848 030 info isotherm com Fax 39 0541 848 563 www isotherm com Indel Marine USA Inc Gateway drive Unit 107 Pompano Beach FL 33069 Ph...

Страница 2: ...4 2 Hoses 4 3 Connections to engine 4 4 Freshwater system connections 4 5 Electrical connections 5 Start up Test 6 Maintenance 6 1 Winterization 6 2 Replacing thermostat 6 3 Replacing heater element 7...

Страница 3: ...o the power net until the water heater tank is filled with water Warning Risk of scalding the hot water in the water heater will be as hot as the engine Caution Consider the chapter 4 5 electrical con...

Страница 4: ...The mounting brackets can be adjusted to the side on Basic and Slim for mounting the tank on a bulkhead Always mount the tank to a suitable shelf or bulkhead and keep in mind the extra weight of the t...

Страница 5: ...OLD WATER IN Fresh warm water out Engine water in or out NPT outside thread Fresh cold water in FRESHWARM WATEROUT 514 NPT outside thread NPT outside thread ENGINE MOTOR WATER ENGINE MOTOR WATER FRESH...

Страница 6: ...ater in ENGINE MOTOR WATER FRESH COLD WATER IN ENGINE MOTOR WATER Second heat exchanger in or out NPT outside thread ENGINE MOTOR WATER ENGINE MOTOR WATER WARM WATER OUT NPT outside thread FRESH WARM...

Страница 7: ...ot water spray 4 2 Hoses For the engine connections use heat re Fig 7 sistant 100 C 210 F reinforced rubber hoses resist ant to anti freeze and pressure approved for 5 bar 70 psi For the fresh water c...

Страница 8: ...s have a free outlet A small quantity of water can drain from the relief valve when the tank is heated The water expands during heating This is a normal situation and indicates the system works proper...

Страница 9: ...hoses and blowing air into the coils to drain any water The tank can now be safely left in the vessel over the winter When leaving the vessel for longer periods it is recommended to take out the powe...

Страница 10: ...from the mounting flange Mount the new heating element with new seal rings and a new big rubber gasket in the opposite order to the description above The inner end of the heating element shall point s...

Страница 11: ...V 1200W X 605021B000003 13 50 7 115V 750W 230V 750W 230V 1200W 230V 2000W X 607521B000003 20 64 115V 750W 230V 750W 230V 1200W 230V 2000W 230V 3000W X 607523BD00003 Double heat exch 20 68 4 115V 750W...

Страница 12: ...115V 750W 230V 750W X 602521S000003 6 5 30 115V 750W 230V 750W X Dimensions See fig 13 Material Heat exchanger coil storage tank and connections stainless steel AISI 316 Outside cover and mouting brac...

Страница 13: ...03 4 2 35 115V 750W 230V 750W X Dimensions See fig 14 Material Heat exchanger coil storage tank and connections stainless steel AISI 316 Outside cover and mouting brackets Stainless steel AISI 304 Out...

Отзывы: