ERRORS SHOWN ON THE DISPLAY (AC / FAN) 

 

Description 

Message Symbol 

Battery Voltage 

(The battery-saver device has cut out.  Voltage has fallen below the value of 10.8V D.C.) 

E1 

 

Fan Over Current Cut-Out 

(The condenser or evaporator fan overloads the central control unit above the limit 
allowed.  Possible cause:  short circuit or blockage of fan rotation.) 

E2 

 

Compressor Locked

 

(The rotor is locked or the pressure inside the cooling circuit is too high.) 

E3 

 

Minimum Compressor Rotation Speed

 

(If the cooling circuit is overloaded, the compressor cannot maintain the minimum rotation 
speed.) 

E4 

 

High Temperature on the Central Control Unit

 

(If the cooling circuit is overloaded or the ambient temperature is high, the central control 
unit signals this situation.) 

E5 

 

Communication Error

 

(There is no communication between the display and the central control unit.) 

E6 

 

Temperature Sensor

 

(Temperature sensor is in short circuit or the wiring of the sensor are not connected and 
thermostat switched off the system.  System is without gas and pressure valve open the 
electric contact switching off the system.) 

E7 

 

 

 

TEMPERATURE UNIT

 

 

When the system is switched off, it is possible to change the temperature unit, choosing between  

°C (Celsius) or °F (Fahrenheit)

 
Press 

VENT + , VENT - , TEMP +  

and

 TEMP -

 , buttons simultaneously to show the present unit (°C) 

on the display, and the 

temperature 

 symbol will 

light up (see fig.4)

 
Quickly press 

VENT +  

or

 VENT –

 to select the unit required. 

 
 

REMOTE CONTROL 

 
The remote control regulates both the conditioning function and the fan function. 
Using the remote control it is possible to: 
 

Switch the system on and off 

Regulate the temperature 

Regulate the fan speed 

Engage the OPTION function 

 

 
 

 

 

 

 

 

 

Содержание sleeping well arctic plus SW2000PLUS

Страница 1: ...AIR CONDITIONER ASSEMBLY MAINTENANCE AND USE INSTRUCTIONS Model Number SW2000PLUS Serial Number __________________ ...

Страница 2: ...ted the right side of the vehicle is the passenger side and the left side of the vehicle is the drivers side Contents Page MAIN COMPONENTS DIMENSIONS 4 TECHNICAL DATA 6 COMPONENTS DISPOSITION 7 9 COOLING SYSTEM 10 ELECTRICAL CONNECTIONS 11 INSTALLATION OF COMPRESSOR BOX EVAPORATOR AIR DIFFUSER INSTALLATION CONDENSER 12 15 ELECTRIC DIAGRAM 16 CENTRAL ELECTRONIC CONTROL UNIT 17 18 OPERATION CONTROL ...

Страница 3: ...3 SLEEPING WELL ARCTIC PLUS ...

Страница 4: ...ontrol panel Auto low voltage Shutdown Battery Saver Evaporator Weight 11 5 Lbs Condenser Weight 15 9 Lbs Compressor Box Weight 54 2 Lbs RECOMMENDED MINIMUM ALTERNATOR REQUIREMENTS FOR PROPER AUXILIARY BATTERY RECHARGE It is recommended that a minimum of 180 amp alternator be used to properly charge the 4 auxiliary batteries Using less than 180 amp alternator will NOT provide enough amperage to co...

Страница 5: ...5 ...

Страница 6: ...6 ...

Страница 7: ...7 ...

Страница 8: ...8 ...

Страница 9: ...9 ...

Страница 10: ...10 ...

Страница 11: ...11 Evaporator MUST be mounted as high as possible in the sleeper area The unit cannot be mounted under the bunk NOTE Install return air vents if unit is enclosed in a cabinet ...

Страница 12: ...12 ...

Страница 13: ...13 ...

Страница 14: ...14 ELECTRIC DIAGRAM COLOR CODE COLOR CODE COLOR CODE B WHITE M BROWN V GREEN G YELLOW N BLACK X WHITE RED H GRAY R RED Y RED BLACK ...

Страница 15: ...15 ...

Страница 16: ...16 All 4 buttons must be pressed at the same time ...

Страница 17: ...eature button is used it will hold the compressor system at low speed V1 This is a battery saving feature that will allow the system to operate for longer periods of time when required VENTILATION FAN If the fan increase or reduction buttons VENT or VENT are pressed when the system is switched off only the evaporator fan is activated with the choice of 6 different speeds shown on the central contr...

Страница 18: ...situation E5 Communication Error There is no communication between the display and the central control unit E6 Temperature Sensor Temperature sensor is in short circuit or the wiring of the sensor are not connected and thermostat switched off the system System is without gas and pressure valve open the electric contact switching off the system E7 TEMPERATURE UNIT When the system is switched off it...

Страница 19: ... the low pressure attachment Switch the Sleeping Well Arctic Plus on for 10 minutes before disconnecting the charging hose s When the refrigerating charge cycle is over check for leaks and proper operation of the system WARNING Compressors use POE oil DO NOT mix PAG oil from previous systems when charging ATTENTION If you cut the G6 refrigerant hose kit comes with 13ft of G6 hose consider that for...

Страница 20: ...maged and are secure Electrical connections are not damaged and are secure Batteries Visual Inspection Mounting bracket hold down is secure Terminal connectors are clear of corrosion and secure SYSTEM TEST If any concerns are found during the Visual Inspection please refer to the Installation Guide for service recommendations Once the above System Maintenance has been completed and any concerns ar...

Страница 21: ...Service Parts Breakdown ...

Страница 22: ......

Страница 23: ......

Страница 24: ......

Страница 25: ......

Страница 26: ... 5 MT SW235 SW 2000 Arctic Evaporator Unit Plastic Frame SW236 Capillary Pipe with Filter New SW 2000 Arctic 9 10 3m SW237 Flexible Ventilation Pipe IMECGH00011AA SW238 Iron Grid Fan 120x120 MOD 120 SW239 Remote Control SW 2000 Arctic Version 2011 SW240 Condenser Plastic Conveyor SW 2000 Arctic SW241 Metallic Plastic Tie IMECDD0038AA SW242 Black Plastic G120 Grid SW243 Fan D12A04SWSZ00 12V 6 3x0 8...

Отзывы: