EN 60947-4-1: 2019: 

 
IEC 61000-4-2:2008 

Electrostatic discharge immunity 

IEC 61000-4-3:2006  

Radiated, radio frequency electromagnetic field immunity 

IEC 61000-4-4:2004 

Electrical fast-transient / burst immunity 

IEC 61000-4-5:2006 

Surge immunity 

IEC 61000-4-6:2008 

Immunity to conducted disturbances induced by radio-frequency fields 

IEC 61000-4-11:2004 

Voltage dips, short interruptions and voltage variations immunity 

 

 

CISPR 11 Group 2, Class A             
 

CISPR11 2015, A1 2016 
CISPR11 2009, A1 2010 

 
EN 55011

  

Radiated Emissions & Conducted Emissions – Radio-frequency disturbance 
characteristics – Limits and methods of measurement.  

 
 

CAUTION:

 This equipment not intended for use in residential or medical environment.  

 
                                           For use in Class B environments, additional external filtering on power lines is 

required.

 

                                           Shielded cables may also be needed. 
 
                                           For use with Phase Angle Control, additional external filtering is 

required

 to pass Class 

A conducted Emissions. A Schaffner filter series FN3270-H or equivalent should be used 
as a line input filter with model A1P & A3P Phase Angle Fired SCRs. 

 
                                           A Schaffner FN2080-16-06 was installed at the AC power input during testing to be 
                                           CISPR32 CE Class B compliant. 
 
                                           Contact Schaffner EMC, Inc. to find the proper filter for your specific application. 
                                           Schaffner EMC Phone (USA) 732-225-9533,  

www.schaffner.com

 

                                             
 

Name of Authorized Representative:

  Paul Evalds 

 

Title of Authorized Representative:

 President 

 

Place of Issue:

  Lewes, Delaware USA 

Date of Issue:

   March 2, 2022 

 

Paul Evalds 

Signature of Authorized Representative 
 
 

www.avatarinstruments.com

  

Page 30

Содержание 110-Z3

Страница 1: ...L TABLE OF CONTENTS Introduction p 2 Features p 2 Description p 3 Theory of Operation p 3 Installation p 4 Electrical Connections p 5 Options p 6 Warranty p 6 Specifications p 7 Troubleshooting p 8 Or...

Страница 2: ...ery easy to identify Indicates important installation operating servicing instructions Indicates dangerous voltage present and risk of electric shock FEATURES UL 508 cUL508 listed CE certified compact...

Страница 3: ...nnected in series with the input provides over current protection in the event of external wiring shorts or too large of a heater load Additionally a MOV metal oxide varistor is connected in parallel...

Страница 4: ...deliver full power to their respective load s at an ambient temperature not to exceed 50 C Use this formula to calculate the minimum size enclosure required Heat is the worst enemy to any electrical d...

Страница 5: ...load LOAD CONNECTION Load connections are equally simple connect the load heater to lugs labeled HTR 1 and HTR 2 see figure 1 for correct wire size and torque specs NOTE For open delta or 4 wire wye...

Страница 6: ...l use MAI milliamp interface card MAI 05V takes a 0 5VDC signal input and outputs 4 20mA MAI 10V takes a 0 10VDC signal input and outputs 4 20mA For third Leg Fusing add 3RD to part number All fuses c...

Страница 7: ...s 250 lbs Wire Gauge and Torque Specifications for 90 C Temp Wire Power Control Maximum Current Rating Circuit Copper Wire Only MINIMUM AWG Wire Lug Torque Spec IN LBS Lug Size 30A 10AWG 35 10 AWG 40A...

Страница 8: ...ure controller PLC etc by placing a milliamp meter in SERIES with the signal wires Heaters on one leg are on all the time others 25 50 short to ground sneak path in between lines Heater or power wires...

Страница 9: ...AC 50 60Hz 600 575 600 VAC 50 60Hz LOAD IN AMPS 30 40 60 80 100 150 200 225 250 350 600 1200 OPTIONS Thru hole Mount only on 40 60 80 100 Amp units Add TH to part number Specify if you need RTV for NE...

Страница 10: ...Page 10...

Страница 11: ...Page 11...

Страница 12: ...Page 12...

Страница 13: ...Page 13...

Страница 14: ...Page 14...

Страница 15: ...Page 15...

Страница 16: ...Page 16...

Страница 17: ...Page 17...

Страница 18: ...Page 18...

Страница 19: ...Page 19...

Страница 20: ...Page 20...

Страница 21: ...Page 21...

Страница 22: ...Page 22...

Страница 23: ...Page 23...

Страница 24: ...Page 24...

Страница 25: ...Page 25...

Страница 26: ...Page 26...

Страница 27: ...Page 27...

Страница 28: ...Page 28...

Страница 29: ...24 to 480 Vac 24 to 600 Vac Frequency 45 or 65 Hz Environmental Rating IP00 for mounting inside an enclosure Meets the essential requirements of the European Union Directives by using the relevant sta...

Страница 30: ...intended for use in residential or medical environment For use in Class B environments additional external filtering on power lines is required Shielded cables may also be needed For use with Phase A...

Страница 31: ...Indeeco Controls 425 Hanley Industrial Court Telephone 314 644 4300 St Louis Missouri 63144 www indeeco com CUSTOMER NOTES Page 31...

Страница 32: ...Indeeco Controls 425 Hanley Industrial Court Telephone 314 644 4300 St Louis Missouri 63144 www indeeco com...