InCoax D2508 Скачать руководство пользователя страница 8

 

 

InCoax DPU – Hardware User Manual

 

1

 

Abbreviations and Definitions 

1.1

 

Abbreviations 

The abbreviations that are used in this document are defined i

Table 1

. 

 

Table 1

 — Abbreviations 

Abbreviation 

Description 

CATV 

Cable TV. 

CE 

CE marking is a certification mark that indicates conformity with health, safety, and 

environmental protection standards for products sold within the European Economic Area. 

CPE 

Customer-Premises Equipment or Customer-Provided Equipment. 

C-VLAN 

Customer VLAN is the VLAN that the customer uses or sees (the inner tag). C-VLAN is the VLAN 

tag the customer is using on their own devices. (See QinQ.) 

DHCP 

Dynamic Host Configuration Protocol is an automatic configuration protocol used to 

automatically assign IP addresses to devices on a TCP/IP network. 

DPU 

Data Processing Unit; often referred to as an Access Node or Control Unit. 

EMC 

Electro Magnetic Compatibility. 

FCC 

The Federal Communications Commission is an independent agency of the United States 

government created by statute to regulate interstate communications by radio, television, wire, 

satellite, and cable. 

IGMP 

Internet Group Management Protocol is a protocol used to establish multicast group 

membership. 

MAC Address 

Media Access Control address is a unique identifier assigned to a Network Interface DPU (NIC) 

for communications at the data link layer of a network segment. MAC addresses are used as a 

network address for most IEEE 802 network technologies, including Ethernet, Wi-Fi, and 

Bluetooth. 

MGMT 

Denotes the Management port on the 

DPU

OFDM 

Orthogonal Frequency-Division Multiplexing is a method of encoding digital data on multiple 

carrier frequencies. 

PA 

Power amplifier 

PHY 

Physical Layer of the OSI model. 

PPPoE 

Point-to-Point Protocol over Ethernet is a network protocol for encapsulating PPP frames inside 

Ethernet frames. 

PON 

Passive Optical Network with its variants XGS-PON, GPON and EPON. 

QAM 

Quadrature Amplitude Modulation is the name of a family of digital modulation methods and a 

related family of analog modulation methods widely used in modern telecommunications to 

transmit information. 

QinQ 

An Ethernet networking standard informally known as QinQ, was incorporated into the base 

IEEE 802.1Q standard in 2011. The IEEE 802.1Q technology improves the utilization of VLANs by 

adding another IEEE 802.1Q tag to tagged packets. (See C-VLAN and S-VLAN.) See referenc

{a}

QoS 

Quality of Service is the ability to provide different priority to different applications, users, or 

data flows, or to guarantee a certain level of performance to a data flow. 

QPSK 

Quadrature Phase-Shift Keying. 

RPF 

Reverse power feeding (RPF) is a technology being standardized by ETSI and the Broadband 

Forum. It allows sending power from the customer CPE to a distribution point (DP), in order to 

power the distribution point unit (DPU). 

RoHS 

Restriction of Hazardous Substances. This is a directive on the restriction of the use of certain 

hazardous substances in electrical and electronic equipment.  See referenc

{b}

SerDes 

Serializer/Deserializer is a pair of functional blocks commonly used in high-speed 

communications to compensate for limited input/output. 

SFP/SFP+ 

Small Form factor Pluggable transceiver. SFP ≤ 1

 Gbps 

and SFP+/Enhanced ≤ 10

 Gbps. 

Содержание D2508

Страница 1: ...al InCoax D2508 EU InCoax D2508 UK InCoax D2508 US InCoax D2508 ER EU InCoax D2508 ER UK InCoax D2508 ER US InCoax D2508 RPF EU InCoax D2508 RPF UK InCoax D2508 RPF US InCoax D2508 RPF ER EU InCoax D2508 RPF ER UK InCoax D2508 RPF ER US ...

Страница 2: ...he appropriate and complete risk analysis evaluation and testing of the products with respect to the relevant specific application or use thereof Neither InCoax Networks AB nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information that is contained herein If you have any suggestions for improvements or amendments or have found errors in this publication...

Страница 3: ...nt Revisions Date Rev Originator Description 2022 05 27 V 1 Leif Ekman Initial version 2022 05 30 V 2 Leif Ekman Updated PA and size weight 2022 08 16 V 2 1 Robert Morau Updated product data 2022 09 21 V 2 2 Robert Morau Updated product data ...

Страница 4: ... 3 2 THE DPU 11 3 2 1 D2508 Input Power alternatives 11 3 2 2 D2508 ER extended range 12 4 COAXIAL NETWORK USE CASES 12 5 DPU WEB INTERFACE ACCESS 12 5 1 ACCESSING THE DPU WEB INTERFACE 12 6 SPECIFICATIONS 12 7 LEGAL INFORMATION 15 7 1 REGULATORY NOTICE AND STATEMENT CLASS A 15 7 1 1 Canada 15 7 1 2 European Union 15 7 1 3 United States of America 15 7 1 4 TUV SUD NRTL 16 7 1 5 Great Britain 16 8 ...

Страница 5: ...medium level of risk which if not avoided could result in death or serious injury Caution indicates a hazard with a low level of risk which if not avoided could result in minor or moderate injury Indicates information considered important but not hazard related Safety Instructions Always make sure to connect all coaxial cables and network cables to DPU before connecting the power cable Ground the ...

Страница 6: ... bend it excessively or pull it To do so may cause fire and electric shock The whole power cord should be discarded if the cable is damaged in any way The power cord shall also be discarded if the plug is damaged Do not place heavy objects on top of the DPU Securely insert the power supply plug as far as it will go Unplug all cables connected to the DPU before moving it It is recommended to unplug...

Страница 7: ...a space with climate control Please refer to section 6 on page 12 for more details about the specified environmental storage conditions Theft and Vandalism Depending on the circumstances for the installation it may be appropriate to mount the equipment i e the DPU Diplexers and Switches in a cabinet that can be locked securely ...

Страница 8: ... port on the DPU OFDM Orthogonal Frequency Division Multiplexing is a method of encoding digital data on multiple carrier frequencies PA Power amplifier PHY Physical Layer of the OSI model PPPoE Point to Point Protocol over Ethernet is a network protocol for encapsulating PPP frames inside Ethernet frames PON Passive Optical Network with its variants XGS PON GPON and EPON QAM Quadrature Amplitude ...

Страница 9: ...A101 is a 1 Gbps Ethernet port Modem These devices will be referred to as the Modem in this document DPU The InCoax D2508 is a eight channel Ethernet over Coax Access Node capable of 2 5 Gbps on the RF port supporting up to 4 Modems The communication with the Modems is based on the MoCA Access 2 5 standard This device will be referred to as the DPU in this document Customer End user or subscriber ...

Страница 10: ...uction This document describes some of the features of an InCoax D2508 model It also includes a technical specification as well as information about the regulatory statements and the proper disposal of the equipment This specific model of the DPU provides a throughput of 2 5 Gbps max 3 2 Gbps on each coax port 3 1 InCoax D2508 MoCA Access DPU System InCoax is a provider of broadband access solutio...

Страница 11: ... TR 069 interface Figure 1 Overview of the Management System 3 2 The DPU The DPU acts as a bridge between the incoming XGS PON GPON EPON or Ethernet access network and customers Ethernet Modem port using the in building coaxial network as transport for data traffic to the Modems The DPU communicates with all Modems over dedicated RF bands in the coaxial network to manage their individual configura...

Страница 12: ... co existence in TV networks with a spectrum up to 1300 MHz Band A C 1025 1675 MHz co existence in TV DOCSIS 3 0 networks with a spectrum up to 1800 MHz Band A D 1125 1675 MHz co existence in TV DOCSIS 3 0 networks with a spectrum up to 1800 MHz Band A E 1375 1675 MHz co existing in TV DOCSIS 3 1 networks with a spectrum up to 1800 MHz 5 DPU Web Interface Access The DPU can be managed via the mana...

Страница 13: ... cooling redundancy Abnormal operation conditions alarms Storage non condensing 40 C to 70 C and 5 to 90 relative humidity RoHS and RoHS 2 See reference b UL 94 V 0 See reference i Power 100 120VAC 50 60Hz 1 2A max or 200 240VAC 50 60Hz 0 6A Power consumption 45 W nominal when PA is activated Automatic power on after power grid failure IEEE Standards IEEE 802 3 Ethernet k IEEE 802 3u Fast Ethernet...

Страница 14: ...from clients Support for PPPoE IA option 0x105 Remote ID Multicast IGMP snooping v2 v3 IGMP filtering per VLAN Configurable IGMP timeout Multicast VLAN Registration Bandwidth reservation per multicast group Max 256 Multicast groups and MAC addresses QoS Traffic classification Mapping and remarking Congestion management Strict priority four separate queues for broadcast multicast and unicast Config...

Страница 15: ...06 66 EC of the European Parliament and of the Council of 6 September 2006 on batteries accumulators waste batteries and accumulators https eur lex europa eu legal content EN TXT uri celex 3A32013L0056 7 1 2 European Union The following information applies if the product is used within the European Union CE EMC Statement Warning This equipment is compliant with Class A of EN 55032 In a residential...

Страница 16: ...l and Electronic Equipment Directive WEEE Directive is the European Community Directive 2002 96 EC on waste electrical and electronic equipment which together with the Restriction of Hazardous Substances Directive RoHS Directive 2002 95 EC also known as RoHS 1 became European Law in February 2003 The WEEE Directive was amended into the Directive 2012 19 EU and the RoHS 1 has been evolved into the ...

Страница 17: ...he network h SFF 8472 standard Specification for Management Interface for SFP members snia org i UL 94 This is a standard for tests for flammability of plastic materials for parts in devices and appliances Underwriters Laboratories V 0 burning stops within 10 seconds on a vertical specimen drips of particles allowed as long as they are not inflamed standardscatalog ul com standards en standard_94_...

Страница 18: ...sf00020 html r WEEE Directive 2012 19 EU This is the European Community Directive on Waste Electrical and Electronic Equipment WEEE which together with the RoHS Directive 2011 65 EU became European Law in February 2003 ec europa eu environment waste weee index_en htm and eur lex europa eu legal content EN TXT uri CELEX 32012L0019 s Battery Directive 2013 56 EU This is an amendment to the Directive...

Страница 19: ...InCoax DPU Hardware User Manual 19 ...

Страница 20: ...InCoax DPU Hardware User Manual 20 InCoax Networks Europe AB Utmarksvägen 4 SE 802 91 Gävle Sweden sales incoax com Revision 2 2 ...

Отзывы: