Australia   Version 2 – March 2016

Product Manual

Analogue 

Addressable 

Syncro View

Serial LCD Repeater Panel

SYNCRO

Содержание SYNCRO

Страница 1: ...Australia Version 2 March 2016 Product Manual Analogue Addressable Syncro View Serial LCD Repeater Panel SYNCRO ...

Страница 2: ... is connected Therefore silencing the buzzer at the host panel will also silence the buzzer on the Syncro View repeater s connected to that panel 2 Safety and mounting 2 1 Safety Suppliers of articles for use at work are required to ensure as reasonably as is practical that the article will be safe and without risk to health when properly used An article is not regarded as properly used if it is u...

Страница 3: ...mount the enclosure in all three mounting positions Suitable fixings should be used at all fixing points such that the unit is securely mounted and is not liable to move once fixed Units should not be mounted in another enclosure or near sources of excessive heat Cables should be connected using suitable cable glands If additional cable entry points are required all swarf and debris caused by dril...

Страница 4: ...nt Mains powered models only 200 millivolts Battery type Yuasa NP Mains powered models only Two 12 Volt 1 9Ah sealed lead acid in series Battery charge voltage Mains powered models only 27 6VDC nominal Battery charge current Mains powered models only 0 2A maximum Battery fuse Mains powered models only 200 milliamp 20mm glass Maximum current draw from batteries Mains powered models only 0 095 Amps ...

Страница 5: ...Syncro_View_AUS_v2 0 docx Page 5 of 12 4 Syncro View fascia Models with enable controls keyswitch Models without enable controls keyswitch ...

Страница 6: ... of the PCB This jumper connects a terminating resistor which needs to be in place at the last unit on the data line If more than one unit is to be fitted then the jumpers must be removed from all units except the last one If there is only one unit fitted then the jumper should be left in place The COMMS LED will flash quickly while the unit is communicating correctly with the control panel and wi...

Страница 7: ... used to switch other voltages or signals 750mA typical wiring connections always read safety notice at front of manual before making any connections 7 Addressing the units To enable the control panel to know whether any units that should be connected have been disconnected and indicate a fault condition each unit must be allocated an address The address switch should never be set with all switche...

Страница 8: ...affect its proper operation a watchdog W DOG LED indicator is latched on and a fault condition signalled to the control panel If a processor re start has occurred this latched fault condition will need to do a reset by pressing the W DOG RESET button on the bottom of the PCB A switch is also provided to manually re start the processor PROC RESET This switch can be used while the units are connecte...

Страница 9: ...tion utility Click on the site name in the left hand window pane to show the option to add panels or repeaters to the system If no panels are already added to the configuration then first add the type of panel required by double clicking on it in the lower panel Add a Syncro view repeater by double click on the View Repeater Icon Double click on the panel to which the View repeater is to be connec...

Страница 10: ...ame location and an address on the serial bus This address should be different for each Syncro View added and different to any other I O boards that may exist on the serial bus Once the configuration file has been loaded into the panel the panel will now expect to see a Syncro View at the address allocated to it and will show a fault condition if the Syncro View is not fitted or is removed ...

Страница 11: ...Page 11 of 12 11 Revision Details Revision Number Reason Date of issue v1 0 Initial Release V2 0 Change of Incite Sydney address Add power supply details into section 6 and corrected PO connection on section 9 drawing 29 03 2016 ...

Страница 12: ...cal support support incitefire com au Melbourne Address Unit 120 45 Gilby Road MT WAVERLEY VIC 3149 Phone 03 9544 2211 Fax 03 9544 2212 Email salesvic incitefire com au Brisbane Address 25 Jeays Street BOWEN HILLS QLD 4006 Phone 07 3252 5366 Fax 07 3252 4099 Email salesqld incitefire com au Perth Address 19 Halley Road BALCATTA WA 6021 Phone 08 9349 2972 Email saleswa incitefire com au ...