C. Storage

  (1) Press the Button to switch off the power.
  (2) Place the Cuff and Controller as shown below.

  BPBIO220 should be transported or stored under the following conditions.

Temperatures Range

- 20 ~ 60˚C

Relative Humidity

10 ~ 85% RH (No Condensation)

Atmospheric Pressure Range

50 ~ 106 kPa

Содержание BPBIO210

Страница 1: ...User s Manual BPBIO210 220...

Страница 2: ...ttps www inbody com E mail info inbody com 2019 InBody Co Ltd All rights reserved Reproduction adaptation or translation of this manual is prohibited without prior written consent from InBody Co Ltd u...

Страница 3: ...m E mail info inbodyusa com InBody Japan Inc JAPAN Tani Bldg 1 28 6 Kameido Koto ku Tokyo 136 0071 JAPAN TEL 81 3 5875 5780 FAX 81 3 5875 5781 Website https www inbody co jp E mail inbody inbody co jp...

Страница 4: ......

Страница 5: ...rage 15 2 BPBIO220 I Product Installation A Product Components and 16 External Appearance B Installation Environment 19 C Installation Instructions 19 D Features and Functions 22 II Blood Pressure Mea...

Страница 6: ...ANGE MIN MAX BPBIO210 220 210T 220T ARTERY M 22 32 cm 9 13 inch RANGE MIN MAX BPBIO210 220 210T 220T ARTERY M 22 32 cm 9 13 inch RANGE MIN MAX BPBIO210 220 210T 220T ARTER Y M 22 32 cm 9 13 inch RANGE...

Страница 7: ...onnection Air Bulb Tube Connection Cuff Tube Connection ARTERY M 22 32 cm 9 13 inch RANGE MIN MAX BPBIO210 220 210T 220T MARK Button On Off Button Cuff Parts ARTERY M 22 32 cm 9 13 inch RANGE MIN MAX...

Страница 8: ...lve Air Bulb Air Bulb Tube Air Bulb Unit Parts Display Parts Pressure Guide Unit for Pulse Rate Unit for Pressure Pressure Display Bar AC Adapter Indicator Pulse Icon Battery Level Indicator Pressure...

Страница 9: ...ot inflict excssive force when opening BPBIO210 The Main Unit of BPBIO210 cannot be bent over a certain angle Opening BPBIO210 with excessive force may incur a damage to the device Caution C Installat...

Страница 10: ...tube tightly to the end Use AA sized Alkaline or Manganese batteries Do not mix new and used batteries Replace all four AA batteries at once when replacing Do not insert batteries with wet hands Make...

Страница 11: ...ot connect or disconnect the AC Adapter with wet hands Do not put heavy objects on the AC Adapter cable Do not use the AC Adapter if it is damaged Warning The dedicated AC Adapter is an optional acces...

Страница 12: ...nly when the pulse is detected more than 5 times When the decompressing is performed too quickly the heart rate may not be checked Decompress at the rate of 2 4mmHg sec to detect the pulse The measure...

Страница 13: ...octor before using the blood pressure monitor if you have any cardiovascular diseases Do not wrap the Cuff around your neck Do not wrap the Cuff Tube around your neck Do not wrap the Air Bulb Tube aro...

Страница 14: ...o turn on the power Icons on the screen and backlight are turned on and off with a sound of a beep Blood pressure can be measured when the number 0 is is displayed on the screen and there is no change...

Страница 15: ...the valve is fully closed Press the Air Bulb repeatedly to pressurize The current pressure value is immediately displayed in the pressure bar on the screen in units of 1 step 2 mmHg and is displayed a...

Страница 16: ...e is displayed on the screen Please review B Measurement related Pulse rate has not been measured on page 56 9 Turning the Power Off Press the Button to switch off the power 7 Depressurization Rotate...

Страница 17: ...with a smooth cloth 2 Place the Cuff and Air Bulb unit as shown below BPBIO210 should be transported or stored under the following conditions Temperature Range 20 60 C Relative Humidity 10 85 RH No Co...

Страница 18: ...size Alkaline Batteries 4EA 2 BPBIO220 ARTER Y M 22 32 cm 9 13 i nch RANGE MIN MAX BPBIO210 220 210T 220T ARTERY M 22 32 cm 9 13 inch RANGE MIN MAX BPBIO210 220 210T 220T ARTERY M 22 32 cm 9 13 inch...

Страница 19: ...on Cuff Tube Connection Cuff Parts Main Unit Parts Backlight Button Battery Insertion ARTERY M 22 32 cm 9 13 inch RANGE MIN MAX BPBIO210 220 210T 220T MARK Button On Off Button ARTERY M 22 32 cm 9 13...

Страница 20: ...Pressure Guide Unit for Pulse Rate Unit for Pressure Pressure Display Bar AC Adapter Indicator Pulse Icon Battery Level Indicator Pressure Pulse Value Exhaust Valve Air Bulb Controller Tube Controlle...

Страница 21: ...06kPa C Installation Instructions 1 Unboxing BPBIO220 After opening BPBIO220 from the box package take out BPBIO220 from the air cap buffer and the vinyl packaging Open BPBIO220 and take out the Cuff...

Страница 22: ...and the Controller Tube all the way to the end Use AA sized Alkaline or Manganese batteries Do not mix new and used batteries Replace all four AA batteries at once when replacing Do not insert batter...

Страница 23: ...onnect or disconnect the AC Adapter with wet hands Do not put heavy objects on the AC Adapter Cable Do not use the AC Adapter if it is damaged Warning The dedicated AC Adapter is an optional accessory...

Страница 24: ...be displayed when the pressure is less than 20mmHg If pulse is not detected or is not constant will be displayed 5 Backlight The backlight turns on or off automatically depending on the brightness of...

Страница 25: ...e Please consult a doctor before using the blood pressure monitor if you have any cardiovascular diseases Do not wrap the Cuff around your neck Do not wrap the Cuff Tube around your neck Do not wrap t...

Страница 26: ...urned on and off with a sound of a beep When there are no changes detected in the pressure within the cuff number 0 will be displayed on the screen which means it s ready for measurement If the pressu...

Страница 27: ...is fully closed Press the Air Bulb repeatedly to pressurize The current pressure value is immediately displayed in the pressure bar on the screen in units of 1 step 2 mmHg and is displayed as a numbe...

Страница 28: ...56 9 Turning the Power Off press the Button to switch off the power MARK Button Clockwise Rotation Increase Exhaust Speed Counter clockwise Rotation Decrease Exhaust Speed Pressing Enable Mark Functio...

Страница 29: ...off the power 2 Place the Cuff and Controller as shown below BPBIO220 should be transported or stored under the following conditions Temperatures Range 20 60 C Relative Humidity 10 85 RH No Condensat...

Страница 30: ...ion If the same error message occurs continuously after exhausting the air from the Cuff the pressure sensor may be defective Please contact InBody Customer Center 080 501 3939 Detection of adapter ab...

Страница 31: ...onnected properly Plug the Controller 4 Pole Connector tightly and push it all the way in The controller is damaged Please contact InBody Customer Center 080 501 3939 Pulse is not being measured Blood...

Страница 32: ...42 cm BP C L 01 M sized Cuff For arm circumstance of 22 to 32 cm BP C M 01 S sized Cuff For arm circumstance of 17 to 22 cm BP C S 01 Air Bulb Available for BPBIO210 Does NOT contain the Wheel Switch...

Страница 33: ...r Adapter Connection Terminal BF type equipment Operating instructions CLASS II equipment Dedicated AC adapter Other Symbols Disposal Guidelines Manufacturer Serial number Authorized representative in...

Страница 34: ...expose the cuff on any liquid 3 Switch off the device completely by disconnecting the batteries or the dedicated AC Adapter if the device malfunctions 4 For inspection repairs please contact the place...

Страница 35: ...t Valve Method Variable Wheel Switch Method Rated Power DC 6V 2A four 1 5V AA size batteries or dedicated AC adapter Rated Input Dedicated AC Adapter AC 100 240V 50 60Hz 0 5A Operating Environment Tem...

Страница 36: ...tion of nearby equipment It may be necessary to take mitigation measures such as re orienting or relocating the ME EQUIPMENT or ME SYSTEM or shielding the location Harmonic Emissions IEC 61000 3 2 N A...

Страница 37: ...ions and Voltage Variations on Power Supply Input Lines IEC 61000 4 11 5 UT 95 dip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 cycles 70 UT 30 dip in UT for 25 cycles 5 UT 95 dip in UT for 5 s 5 UT 9...

Страница 38: ...tures objects and people a Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV br...

Страница 39: ......

Страница 40: ...www inbody com 2019 InBody Co Ltd All rights reserved BM ENG K6 A 190812...

Отзывы: