Installation positions
Mounting
d
imensions
(in mm)
Model no.
A
B
C
D
E
F
G
H
PSG 15GL
324
460
320
62
100
85
G½
100
PSG 25GL
365
550
360
62
100
85
G½
100
Water connections
Caution
A.
Do not connect the inlet directly to water lifting pump.
B.
Do not SWITCH ON water Heater without water filled in tank.
1.
In case inlet water pressure in more than 5.5 MPa or water pressure head 80 meter, install the
dead weight valve before inlet as shown in Picture 2 (not provided with this unit).
2.
Minimum height between the water heater and water supply tank should be at least 4 meter.
3.
For connecting the inlet & outlet between water heater and bathroom fittings, use metal
flexible pipe.
4.
Cold water inlet is marked blue and hot water outlet is marked with red.
5.
First, fix the multifunction valve (MFV) to inlet of water heater.
6.
Connect cold water inlet to the end of MFV with metal flexible pipe.
7.
Open inlet water tap and allow the water to fill in the water heater, make sure that the water
starts flowing from outlet of water heater.
8.
Connect he outlet with metal flexible pipe to hot water outlet point of bath fitting. Open the
tap & valve and check the water flow through the hot water tap.
9.
Connect MFV with PVC pipe for drain see picture 3.
Caution
Ensure no leakage of water through inlet and outlet joints.
6
To water inlet
Lever for Drain Out
of Water at Annual
Maintenance
To Flexible Pipe
Multi functional
Safety Valve
Dead Weight Valve
D
E
A
B
F
G
C
Содержание PSG 15GL