background image

Press the POWER button.

If no selection is made within 5 minutes, the power is 

automatically shut off.

Press the desired program button.

The reclining will start after a short time.

(

See the table on P20)

Then, the shiatsu point locator indicator turns 

on and shiatsu point locating is performed.

[Note]

Sit as far back as possible in the chair and put 

your head against the headrest in a relaxed 

manner.

Shiatsu points cannot be accurately located if 

your body is raised.

The shoulder positions can be adjusted.

The ROLLER buttons flash and you can adjust the vertical 

position of the rollers. If no adjustment is required, do not use 

these buttons.

The program starts.

When shiatsu point locating is completed, 

the Complete light turns on and the program 

starts.

During operation, you can adjust conditions 

such as the roller push-out and the air 

intensity.

Program completed.

When the massage program finishes, the rollers return to 

their storage positions (upper part of the seat back). Then 

the power to the remote control is shut off. However, the 

reclining of the seat back and the up or down adjustment of 

the leg rest can still be operated.

PRESET PROGRAMS

Preset Program Massages

 12 automatic programs provide a variety of different massages to relieve fatigue.

 With the preset program buttons, you can choose your favorite program to give you a massage according to the 

preset menu.

Changing Courses

Before the course in progress finishes, you can change it to another course. After a total duration of 30 minutes, the course in 

progress stops even if not completed.

*  It may take some time to change courses because the air bags for the BACK 3-D function must be deflated before changing 

the course.

Switching from One Preset Program in Progress to Another

When one preset program button is pressed while another preset program is in progress, the rollers return to their storage 

positions, then the selected program starts from the automatic shiatsu point location operation.

Switching from a Preset Program to Manual Selection Mode

When one of the buttons for manual selection mode located inside the panel of the remote control is pressed while a preset 

program is in progress, the preset program immediately stops, and the selected operation starts.

To select an air massage, press the POWER button to stop the preset program in progress before making the selection.

Stopping in the Middle of a Massage

To stop mid-massage, press the POWER button. The rollers will return to their storage positions and stop.

In an emergency or if there is some malfunction during the operation of the chair, press the EMERGENCY STOP button. The 

rollers will stop immediately.

After confirming safety, press the POWER button. The rollers will return to their storage positions and stop.

 Caution

If you feel the massage is too strong, reduce the stimulation according to this Operating Manual. If this solution does 

not work, stop using and contact the vendor.

 →

May result in injury if you continue use with high stimulation under such circumstances.

Do not place hands or feet into the roller tracks, into the space between the seat back and the seat or into the moving 

parts. Do not sit wearing hard objects, such as hair accessories, a necklace, watch, bracelet, or ring.

If your leg or foot comes out of the leg rest during the massage, do not try to force it back in.

[P

RE

SE

T P

ROG
RA

M

S]

Содержание HCP-9101A

Страница 1: ...NTS DESCRIPTION 5 BEFORE USE 7 POSITION ADJUSTMENT 11 AFTER USE 16 PROGRAMS SELECTION 17 PRESET PROGRAMS 19 MANUAL SELECTION 21 TROUBLESHOOTING 25 REGULAR MAINTENANCE 26 FOR SAFETY FAQ 27 CARE AND STO...

Страница 2: ...including inflammation of the hypodermis Persons with suspected acute neck sprain whiplash injury RequiredAction Persons with any of the following conditions should seek medical advice before using th...

Страница 3: ...for repairs Keep the cord away from heated surfaces May result in electric shock short circuit or combustion Children and those who are unable to express intention should not use the chair It is advi...

Страница 4: ...ny abnormality stop the chair immediately and turn the main POWER switch to OFF to prevent an accident Unplug the power plug from the wall outlet Contact the vendor for inspection or repairs Electric...

Страница 5: ...ms and wellbeing programs allow you to select the optimal program according to your purpose Quick programs allow you to refresh yourself in a short period of time And the manual selection mode allows...

Страница 6: ...ck Folding Clasp Reclining Seat Back Hand Massage Unit left Cord Connector Power Cord Plug Shoulder Massage Air Cushion x 4 Headrest large Headrest small Rollers Storage roller position is inside the...

Страница 7: ...topped in an emergency EMERGENCY STOP Button Use this button to shut the chair off immediately in an emergency or if there is a malfunction during operation of the chair The rollers will stop immediat...

Страница 8: ...r Do not install the chair where it can come into contact with direct heat such as direct sunlight or a radiator To avoid damaging floor surfaces and to cut down on the noise of the chair it may be be...

Страница 9: ...ack To fold the reclining seat back Pull up the lever of the seat back folding clasp Push the top side of the seat back toward the front and fold down the seat back BEFORE USE To Carry Moving Method 1...

Страница 10: ...ft that projects from the shoulder massage unit into the hole on the side of the seat back and fully push it in Install so that the air inlet is at the top There are left and right shoulder massage un...

Страница 11: ...left side at the same time See Changing the Remote Control Position on page 11 Remote Control Holder Remote Control Holder Installation Area Main Power Connection 1 First plug the power cord into the...

Страница 12: ...ide By following the procedure below you can change the remote control position to the left side 1 Turn over the first cloth between the leg rest and the seat 2 Lay out the remote control cable 3 Retu...

Страница 13: ...ach to the cloth with the velcro Shiatsu Pads A and B and the Shiatsu Sheet can be freely combined Use them together as you like Remove them if you feel that the stimulation is too intense How to Use...

Страница 14: ...to lower the reclining seat back Release Release Press Press Press the button to start the operation Release the button to stop the operation When you press and hold a RECLINE button for approx 2 seco...

Страница 15: ...he leg rest by hand Caution Do not place anything other than legs and feet on the leg rest To raise the leg rest Press the top LEG REST button to raise the leg rest To lower the leg rest Press the bot...

Страница 16: ...POSITION ADJUSTMENT Adjust the position of the massage unit air bags so that they contact the shoulder joint areas between the neck and the shoulder How to Use the Hand Massage Unit The hand massage...

Страница 17: ...power cord Unplug the chair from the wall outlet Caution Be sure to set the main POWER switch to OFF after every use and to unplug the chair from the wall outlet Accident or injury may result if child...

Страница 18: ...Full Body Program This program is recommended for persons who feel symptoms such as lack of energy or fatigue Shoulder Program Lower Back Program Stretch Hi Program This program is recommended for pe...

Страница 19: ...th Program This massage is focused on the lower half of the body in particular the area around the pelvis and buttocks This program is recommended for persons who want to relax This program takes its...

Страница 20: ...me time to change courses because the air bags for the BACK 3 D function must be deflated before changing the course Switching from One Preset Program in Progress to Another When one preset program bu...

Страница 21: ...uttons flash The rollers move up while this button is pressed The rollers move down while this button is pressed Various Adjustments Program Operations and Adjustments Operates can be adjusted Does no...

Страница 22: ...is pressed Shiatsu 1 Shiatsu 2 or stop can be selected Shiatsu 1 Shiatsu 2 Air Massage Operation Button Action Indication Intensity Adjustment Shoulder Massage Air massage to the shoulders Hand Air m...

Страница 23: ...k stop using and contact the vendor May result in injury if you continue use with high stimulation under such circumstances Do not place hands or feet into the roller tracks into the space between the...

Страница 24: ...d Tapping Shiatsu Tapping Shiatsu or stop can be selected Tapping is shown in the example above Full Part Rolling Selection Press the button 1st time Press the button 2nd time Press the button 3rd tim...

Страница 25: ...utes keeping appropriate intervals between each massage session MANUAL SELECTION Roller Position Adjustment Buttons and Indicators Description When full rolling is selected Changes between up and down...

Страница 26: ...after about 5 seconds See P10 Sit further back in the chair so that your head rests firmly on the headrest Or you can adjust the shoulder position with the ROLLER buttons immediately after the shiatsu...

Страница 27: ...the main POWER switch set to ON The power cord has been cracked or scratched The power cord or plug becomes abnormally hot The chair produces a burnt smell abnormal sound or vibration The auto timer...

Страница 28: ...houlder units are removed No Although for structural reasons they can be removed and reattached if massage is performed while the units are removed it will result in air leaks and affect the other air...

Страница 29: ...main POWER switch located at the back right of the chair to OFF Unplug the chair from the wall outlet After performing the above contact the vendor for assistance The remote control panel has come off...

Страница 30: ...nd Covers Soak a piece of soft cloth in lukewarm water in which a small amount of mild detergent has been added Then thoroughly wring it out before cleaning off any spots or grime Caution The fabric c...

Страница 31: ...rouble status 6 Proof of purchase If the warranty is valid A service charge may apply subject to the nature of the trouble and or repair according to the terms of the warranty See the warranty for ful...

Страница 32: ...rox 37 kPa Auto Timer Approx 15 minutes preset programs vary in duration Leg Rest Adjustment Range Approx 9 8 inch Reclining Angle Approx 120 170 from floor level continuous motion Automatic reclining...

Отзывы: