background image

 

 

-

 23 

-

 

 
 
 

4.2

 

UART Usage 

4.2.1

 

UART configuration 

RS-232 UART port on Expander module provides a serial connection for users to manage 

with terminal application such as Tera Term, Hyper Term…etc. 

 

To manage Expander through UART port, the settings below have to be properly configured 

to make it work. 

Baud Rate 

: 115200 

Data  

: 8 bit 

Parity 

 

: None 

Stop Bit   

: 1 bit 

Flow Control  : None 

 

 

When connected, there is a prompt display on terminal then users can start typing CLI 

commands 

 

 
 

 

Содержание IW-RS316-03

Страница 1: ...IW RS316 03 User s Manual...

Страница 2: ...2 2 3 2 Installing a Fan Module P 12 2 4 Removing and Installing a PSU Module P 13 2 4 1 Removing a PSU Module P 13 2 4 2 Installing a PSU Module P 14 2 5 Installing Slide Rail P 14 2 5 1 Identifying...

Страница 3: ...isk PHY Status P 25 4 2 5 Firmware Update P 26 4 2 5 1 SAS Expander Operation Firmware Update P 26 4 2 5 2 SAS Expander MFG CFG Binary Update P 28 5 Compatibility Lists P 29 6 Q A P 29 7 Technical Sup...

Страница 4: ...3...

Страница 5: ...is designed to operate in a typical office environment The location should be a clean dry and free of airborne particles a well ventilated room and away from sources of heat including direct sunlight...

Страница 6: ...is a short length of conductor used to close open or bypass part of an electronic circuit Jumpers on In Win backplane have a small tab on top that you can pick up with your fingertips Grip the jumper...

Страница 7: ...CRPS Redundant Watt 800W Indicator Power LED LAN1 LAN2 LAN3 LAN4 LED System LED ID LED Front Control Panel Power on off Reset NMI ID SW USB3 0 x1 Mute button Backplane MINI SAS HD 12Gb s with expander...

Страница 8: ...7 1 Product Introduction 1 1 Box Content...

Страница 9: ...When you open the chassis should be like the diagram shows Rear top cover CRPS Redundant or Single module power supply Middle top cover 16 x 3 5 tool less HDD slots Max PWM Fan 3pcs ATX or EEB M B Fro...

Страница 10: ...N A Press the button to activate system reset 4 Chassis ID Button with LED Blue Solid on Press the button to activate system identification 5 System Fail LED Red Solid on System Fault Beeper 6 LAN LE...

Страница 11: ...epend on M B specification The I O shield should come with motherboard or provided by motherboard vendors 4 7 Full Height PCI E Slot The slot support 120mm high profile cards The bracket should be rem...

Страница 12: ...perform quick hard disks replacement 2 1 1 Installing a Hard Drive Step 1 Press the release button then pull outward the handle Step 2 Insert the hard drive to the slot Step 3 Push back the lever unt...

Страница 13: ...p 2 Loosen the screws of the rear top cover on the both sides pull back the cover and lift to remove Step 3 To place the cover mount the rear cover and push it to the fitted location Screw up to fix t...

Страница 14: ...fan bar Step 2 Unplug the fans power cable from the motherboard if necessary Step 3 Hold and lift the fan module from the chassis Step 1 Step 2 Step 3 2 3 2 Installing a Fan Module Step 1 Hold and pu...

Страница 15: ...n system is capable to keep working whether as one power supply unit is failure To replace it user only need to release the failure one then insert a good one 2 4 1 Removing a PSU Module Step 1 Press...

Страница 16: ...to let users mount the chassis on to the cabinet 2 5 1 Identifying the slide Rail The slide rail by your order might be different You can reference the quick installation guide inside the slide rail p...

Страница 17: ...he rear rack of the cabinet Step 2 Pull back to and push bracket s standoff into the screw holes on the rack if your action is correct you will hear a click Step 3 Extend the opposite side of bracket...

Страница 18: ...rect Step 3 Insert the inner rail on the both side of chassis into the middle rail Step 4 Push the chassis to the terminal position then pull the blue release tab to continue Step 5 When reaching the...

Страница 19: ...board s mounting holes you may use a flathead screw driver Step 3 Place the motherboard down to the chassis and make sure the pillars threaded holes are matching the mounting holes on the motherboard...

Страница 20: ...nt IO Indication Power Switch PWR SW Brown Power ON OFF Button with LED Power LED PWR LED Purple Power ON OFF Button with LED NMI Switch NMI SW Yellow NMI Button Reset Switch RST SW Orange System Rese...

Страница 21: ...dary SAS Expander Slot JD1 JD3 MCU Programming Factory only FPC1 Front Switch FPC IO Board Connector FPC2 Front Switch FPC IO Board Connector Factory only PW1 ATX 2x7P 5V Power Connector PW2 ATX 2x8P1...

Страница 22: ...cation Description GF1 BP Golden Finger Connector GF2 IO Board Golden Finger Connector EFN1 Expander FAN Connector JM1 Single Dual Power Module Select Single Jumper 1 2 Dual Jumper 2 3 JD1 ICE Debug P...

Страница 23: ...eliable high performance data rate HDDs hot swap able HDD is hot swap able No need to shutdown system for HDD installation and or replacement while there is HDD failure happens or intend to add new HD...

Страница 24: ...with terminal application such as Tera Term Hyper Term etc To manage Expander through UART port the settings below have to be properly configured to make it work Baud Rate 115200 Data 8 bit Parity Non...

Страница 25: ...24 4 2 2 System Revision To check the Expander revision typing rev and sys rev to get the expander information such as Vendor ID Firmware Version SAS Address etc...

Страница 26: ...25 4 2 3 System Monitoring To monitor the enclosure sensor status such as temperature and DC power amplitude by command sys in the UART...

Страница 27: ...26 4 2 4 Disk PHY Status To monitor the SAS PHY status typing Phyinfo or sys hdd to check Users can check the disk link status by using these commands...

Страница 28: ...are 2 firmware for expander Be sure these binary files are available in the host before conducting firmware update 1 SAS Expander Operation Firmware 2 SAS Expander MFG CFG binary The updated firmware...

Страница 29: ...28 D Select the correct SAS Expander firmware file E Click on Open to start the selected firmware transferring to SAS Expander F Terminal would then start firmware transfer...

Страница 30: ...peration firmware upgrade typing mfgdl on console B Type y to commit MFG file upgrade C Select xmodem as the file transfer protocol D Select the correct MFG CFG file from file browser E Click Open to...

Страница 31: ...osure use hot swap expander modules to satisfy the requirement of both capacity expansion and JBOD redundancy 3 Why IW RJ JBOD enclosure needs 2 expander modules A It is for redundancy If user does no...

Страница 32: ...this moment if this requirement is mandatory please contact In Win sales for OEM service 10 Is the storage server or JBOD must be full populated to work A No you can populate partial bays and start th...

Страница 33: ...e the quantity of fans A The quantity of fan is related to the radiating efficiency Usually the quantity of fans depends on the system loading and the heat generation Unless you have tested or we stro...

Страница 34: ...33 7 Technical Support If you need help on installation or troubleshooting you can contact your local In Win partner or send email to In Win s local contact for technical assistance...

Отзывы: