NCSP3 Functionality Test  

The Body Control Module (BCM) should be wired correctly, without 
loose connections, and connected to 12 VDC at pin 42. A 

RED

 LED will 

indicate that the BCM is receiving 12 VDC.  

 

The BCM has override switches available.  There is a knob and switch 
that correspond to motor functions 1 – 5.  The knob chooses the 
motor and the switch actuates the motor to go in or out.  There are 
also buttons labeled AW1 In & Out and AW2 In & Out that act as 
overrides for the optional AUX Motor Relay Control Kit.  The switches 
and buttons are momentary and will activate the component only 
while pressed in either direction. 

The BCM and Display Commander (DC) communicate with each other 
through an RV-C (CAN BUS) connection.  This RV-C communication 
also allows the DC to connect to a third party AC translator module 
(gateway) so that you can perform the HVAC functions from the DC. 

The DC will be mounted in an "all access" area near the entrance. On 
the DC, press and release the Power button (the left button) to wake 
up the DC.  After a moment, the Passcode Screen will appear. Enter 
your Passcode. If this is the first time the DC has been powered on, an 

End User License Agreement (EULA) screen will appear. Upon 
accepting the EULA, the “Enter New Passcode” screen will appear.  
Enter your new passcode and confirm. 

 

The DC will now bring up the Home Screen If the Floor Plan has been 
loaded, all of the devices should be listed with corresponding 
actitation buttons. 

 

Go through all the functions and make sure they are operating properly.  All 
the functions should be smooth and instantaneous.  Ensure all the Home 
Page Hot keys actuate/turn on the corresponding functions. 

 