18
Operation Manual Fire Lighter Revision 2
Storage of your Ground Effect Fire Lighter
Ground Effect Fire Lighters should always be stored in a well ventilated dry and secure place away from direct
sunlight.
Fault finding with Ground Effect Fire Lighter
Fire Lighter not pumping?
Is the Fuel Pump running
Yes
Check the Hopper contains product
Check there is no damage to the Fuel Lines
There could be a blockage in the Fuel Lines or Discharge Valve
Check that the Breather Hose is clear and not obstructed
Is the Fuel Pump running
No
Check the power supply from the helicopter
Check the 10amp fuse in the Control Enclosure
Check an obstruction within the Fuel Pump
Ignitor not working
Evacuate all of the flammable product and vapour from the Fire Lighter
Ensure that it is safe to work on the fault
Isolate the Fuel Pump
Check the gap between the Earth and Ignition Probes
Check the High Tension Lead connection to the Ignition Coil
Check the Earth wire on the Top of the Discharge Valve has a sound connection
Check 5amp fuse in the Control Enclosure