Nozzle Leak Detector Operators Instructions

A. Without machine interface

1. Attach Bracket Assembly to Nozzle with hose clamp (sold 

separately).

2. Affix the thermocouple into bracket and tighten in place with 

set screw .

3. With unit toggled to OFF position, plug thermocouple into the 

thermocouple socket located on the right side of the unit.

4. Plug the leak detector unit into a standard 120V grounded 

receptacle.

5. Toggle switch to ON position to power up the unit.

6. Adjust the set point on the controller to approximately 100 to 

150°F below the nozzle zone temperature.

•  To adjust the set point temperature on the controller, refer 

to the Model 3300 Controller instruction manual.

•  Instructions to lock the set point temperature are included 

in the Model 3300 Controller Instruction manual.

7. When a leak is detected, the audible alarm will sound and the 

LED will light up.  Turn unit OFF and repair leak.  

•  NOTE: Do not just toggle switch to OFF position without 

repairing leak. 

•  To reset controller, follow instructions on the Model 3300 

Controller Instruction manual

•  Audible alarm volume can be adjusted by rotating the 

louver on alarm face.

8. After the leak is fixed and the controller is reset turn unit back 

ON.  The audible alarm will remain silent and the LED warning 
light will remain off until another leak is detected.

B. With Machine Interface

1. Attach Bracket Assembly to Nozzle with hose clamp (sold 

separately).

2. Affix the thermocouple into bracket and tighten in place with 

set screw.

3. With unit toggled to OFF position, plug thermocouple into the 

thermocouple socket located on the right side of the unit.

4. Wire plugs (included with unit) to use for input and output.

•  Hot wire goes to brass screw
•  Neutral wire goes to silver screw

NOTE: there is no ground for input and output
CAUTION: ONLY WIRE PLUGS WHEN THERE IS NO 
VOLTAGE PRESENT

5. Insert plugs from machine into appropriate receptacles 

located on side of unit.

•  Input receptacle is for input voltage at standard 120v non 

grounded power.

•  Output receptacle is for output voltage at standard 120v 

non grounded power.

Note: Input receptacle will always have power and Output 
receptacle will have no power until a leak is detected.

6. Plug the leak detector unit into a standard 120V grounded 

receptacle.

7. Toggle the switch to ON position to power up the unit.

8. Adjust the set point on the controller to approximately 100 to 

150°F below the nozzle zone temperature.

•  To adjust the set point temperature on the controller, refer 

to the Model 3300 Controller instruction manual.

•  Instructions to lock the set point temperature are included 

in the Model 3300 Controller Instruction manual.

9. When a leak is detected, the audible alarm will sound and the 

LED will light up. Turn unit OFF and repair leak.

•  NOTE: Do not just toggle switch to OFF position without 

repairing leak. 

•  To reset controller, follow instructions on the Model 3300 

Controller Instruction manual.

•  Audible alarm volume can be adjusted by rotating the 

louver on alarm face.

10. After the leak is fixed and the controller is reset, toggle 

switch back to ON position. The audible alarm will remain 
silent and the LED warning light will remain off until another 
leak is detected.

Nozzle Leak Detector Specifications

Unit ON with NO Leaks

Sonalert Alarm OFF/LED OFF/Output  

Receptacle has NO power

Voltage: 120V
Amperage: (PEAK) 0.022 amps
(AVERAGE) 0.016 amps
Power/Wattage: (PEAK) 1.4 W
(AVERAGE) 1 W

Unit ON DETECTING Leaks

Sonalert Alarm ON/LED ON/Output  

Receptacle HAS power

Voltage: 120V
Amperage: (PEAK) 0.034 amps
(AVERAGE) 0.032 amps
Power/Wattage: (PEAK) 3.5 W
(AVERAGE) 3.4 W