ENVIROTECH ALARMS - IMRITA - INSTALLATION INSTRUCTIONS - VERSION 1.0
Note: Only exit the menu if you do not wish to input any other settings. If you do wish to continue
with other settings, you can exit the menu at the end and all changes will be stored/saved.
Use the CLOSE button to
increment the numbers to the
desired threshold time.
MENU
OPEN
CLOSE
Volume
Time
Leak Time
Max Flow
L
min
L/min
Press the OPEN button to
toggle to the 10s of seconds
setting. This will start to flash.
MENU
OPEN
CLOSE
Volume
Time
Leak Time
Max Flow
L
min
L/min
MENU
OPEN
CLOSE
Volume
Time
Leak Time
Max Flow
L
min
L/min
Press and hold the MENU
button for 5 seconds. This
enters the setting mode.
Press the CLOSE button to
increment the amount up in
seconds.
MENU
OPEN
CLOSE
Volume
Time
Leak Time
Max Flow
L
min
L/min
Press the MENU button again
six times to enter auto restore
setting.
Note: If still in the setting
mode, press the MENU button
once to enter the auto restore
setting
MENU
OPEN
CLOSE
Volume
Time
Leak Time
Max Flow
L
min
L/min
Press and hold the
MENU button for 3 seconds to
store water time settings.
Note: In the example above, if the main stop cock is manually shut within 20 seconds . Any amount
above this will trigger an alarm and shut the valve. The maximum amount that can be set is 999
seconds. Setting the value to zero will switch off this feature.
MENU
OPEN
CLOSE
Volume
Time
Leak Time
Max Flow
L
min
L/min
Setting the auto restore:
This is used to automatically open the valve following a volume, time or max flow alarm providing the main stop cock has
been manually shut. This is set in seconds.