• Make sure that it is clean and watertight then carefully position the tank in the base unit (Fig. 5).
• With dry hands, plug in and switch on the appliance. The red warning light lights up and turns green within a few
seconds. The appliance starts working.
• You can then adjust to the desired vapour intensity by turning the vapour intensity control button.
• Once the tank is empty, the safety mechanism inside the appliance will automatically stop the electricity supply if the
circuit is overheating.
• Strict monitoring is required at all times to prevent any risk.
Fig. 2
Fig. 4
Fig. 3
Fig. 5
Caution:
DESPITE THE SAFETY MACHANISM WHICH STOPS THE TRANSDUCER FROM WORKING, WHENEVER POSSIBLE
SWITCH OFF THE APPLIANCE WHEN NOT IN USE.
MAINTENANCE AND STORAGE:
If the water is hard, i.e. it contains a lot of calcium and magnesium, this can deposit a “white powder” inside the
appliance and cause a thick build-up on the surface of the basin, transducer (ceramic disc which produces the
ultrasounds) and interior walls of the water tank. Build-up on the surface of the transducer prevents the appliance from
working correctly.
We recommend:
1) always using water which has been boiled and then cooled or distilled water,
2) cleaning the tank every 3 days, cleaning the transducer every week,
3) changing the water in the tank regularly so that it is fresh, not leaving it in the appliance for more than 2 days,
4) cleaning the whole appliance and making sure that all its components are completely dry when not in use.
To clean the transducer:
1) Place 2 to 5 drops of vinegar on the surface and leave for 2 to 5 minutes.
2) Brush the build-up from the surface using a soft brush. Do not use a hard tool to scrape the surface.
3) Rinse the transducer in clean water.
4) Do not use soap or any other basic substances to clean the transducer.
To clean the basin unit:
1) Clean the water basin using a soft cloth and vinegar if there is build-up OR calcium deposits inside.
2) If the build-up is covering the safety switch, place a few drops of vinegar on it and clean using the brush.
3) Rinse the basin with clean water.