![impro IMPROX DBV Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/impro/improx-dbv/improx-dbv_installation-manual_2049690003.webp)
XDB300-0-0-GB-04
December 2007
Page 3
INSTALLATION INFORMATION
Accessories
Find the following when unpacking the ImproX DBv:
NOTE:
The ImproX TD included in the construction of the ImproX DBv uses the
standard ImproX TT Hardware, with modified Firmware. The ImproX TD will
NOT, however, operate as an ImproX TT.
XDB902-1-0-GB-XX
NOTE:
This version of the Drop Box does NOT include a Tag Retention Box for
catching the Tags.
An ImproX Vertical Mount Drop Box with an open frame construction. The Drop
Box includes a 1 m (7 ft) twisted, black, 0.5 mm, 2-Conductor Power Cable.
A Mechanical Drilling and Cutting Template.
Two Fixed Address Labels.
XDB903-1-0-GB-XX
An ImproX Vertical Mount Drop Box with a white powder coated mild steel
Cabinet. The Drop Box Cabinets design includes a Tag Retention Box for
catching the Tags. The Drop Box Throat Assembly includes a 1 m (7 ft) twisted,
black, 0.5 mm, 2-Conductor Power Cable.
One mild steel Mounting Bracket.
Two Keys.
Two PG7 Plastic Cable Glands.
One M10 Rawl Bolt.
Two Fixed Address Labels.
General
Remember the following when installing the ImproX DBv:
Communications Distance
The RS485 communications distance between the ImproX Controller and the LAST
ImproX unit in a cable run, MUST NOT exceed 1 km (1 090 yd). Achieve this by using
good quality screened, twisted 2-pair cable, with the screen EARTHED at one end.
Jumper Links
Long transmission lines or multiple “star” connections, may cause communication
problems. Placing a Jumper Link across the jumper [TR1] in the LAST UNIT AT THE
END OF THE CABLE RUN should solve the problem.
EARTH Connection
Connect the Drop Box to a good EARTH point. Using the RS485 Port, connect the
EARTH Lead to the „
‟ Terminal. Mains EARTH can be used, but electrical noise
may exist.