impro IMPROX DBV Скачать руководство пользователя страница 3

 

XDB300-0-0-GB-04 

December 2007 

Page 3 

 

INSTALLATION INFORMATION 

Accessories 

Find the following when unpacking the ImproX DBv: 

NOTE:   

The ImproX TD included in the construction of the ImproX DBv uses the 
standard ImproX TT Hardware, with modified Firmware.  The ImproX TD will 
NOT, however, operate as an ImproX TT. 

XDB902-1-0-GB-XX 

NOTE:   

This version of the Drop Box does NOT include a Tag Retention Box for 
catching the Tags. 

 

An ImproX Vertical Mount Drop Box with an open frame construction.  The Drop 
Box includes a 1 m (7 ft) twisted, black, 0.5 mm, 2-Conductor Power Cable. 

 

A Mechanical Drilling and Cutting Template. 

 

Two Fixed Address Labels. 

XDB903-1-0-GB-XX 

 

An ImproX Vertical Mount Drop Box with a white powder coated mild steel 
Cabinet.  The Drop Box Cabinets design includes a Tag Retention Box for 
catching the Tags.  The Drop Box Throat Assembly includes a 1 m (7 ft) twisted, 
black, 0.5 mm, 2-Conductor Power Cable. 

 

One mild steel Mounting Bracket. 

 

Two Keys.   

 

Two PG7 Plastic Cable Glands. 

 

One M10 Rawl Bolt. 

 

Two Fixed Address Labels. 

General 

Remember the following when installing the ImproX DBv: 

Communications Distance 

The RS485 communications distance between the ImproX Controller and the LAST 
ImproX unit in a cable run, MUST NOT exceed 1 km (1 090 yd).  Achieve this by using 
good quality screened, twisted 2-pair cable, with the screen EARTHED at one end. 

Jumper Links 

Long transmission lines or multiple “star” connections, may cause communication 
problems.  Placing a Jumper Link across the jumper [TR1] in the LAST UNIT AT THE 
END OF THE CABLE RUN should solve the problem. 

EARTH Connection 

Connect the Drop Box to a good EARTH point.  Using the RS485 Port, connect the 
EARTH Lead to the „

‟ Terminal.  Mains EARTH can be used, but electrical noise 

may exist. 

Содержание IMPROX DBV

Страница 1: ...or outdoor environment similar to IP54 XDB903 1 0 GB XX The Drop Box is designed to work in an indoor or outdoor environment similar to IP66 Input Voltage 12 V DC polarity sensitive Power Requirement...

Страница 2: ...V continuous 80 V to 80 V surge LED Diagnostic Indicators Status LED Power On Continuous Red Upgrade Mode Flashing Red Steady RS485 Communications Failure Flashing Red Intermittent Incoming RS485 Dat...

Страница 3: ...es a Tag Retention Box for catching the Tags The Drop Box Throat Assembly includes a 1 m 7 ft twisted black 0 5 mm 2 Conductor Power Cable One mild steel Mounting Bracket Two Keys Two PG7 Plastic Cabl...

Страница 4: ...er ranges between 2 m to 16 m 7 ft to 53 ft Achieve this by using good quality screened twisted pair cable Distance between the Antenna Reader and the Drop Box To avoid mutual interference install the...

Страница 5: ...the outside of the counter and the Throat Assembly is mounted on the inside of the counter CAUTION Make allowance during installation for the Tag Retention Box Ensure that the Tag Retention Box does N...

Страница 6: ...e of the Drop Box 2 Mark out and drill the mounting hole 3 Fix the Drop Box into position using the Mounting Bracket and M10 Rawl Bolt 4 Remove the Face Plate Assembly including the Throat Assembly 5...

Страница 7: ...off the lip located at position 1 see Figure 3 3 Turn the Tag Retention Box so that the lip faces away from the open Cabinet door 4 Hang the Tag Retention Box on the lip located at position 2 see Fig...

Страница 8: ...0 GB 04 December 2007 Page 8 ELECTRICAL CONNECTIONS Typical Electrical Connections Figure 4 shows a typical electrical connection diagram for the ImproX DBv Figure 4 Typical ImproX DBv Electrical Con...

Страница 9: ...ed Address Labels in the position of the Drop Box on the sketched site plan When the system installation is complete and all the units are represented on the site plan by their Fixed Address Labels fi...

Страница 10: ...XDB300 0 0 GB 04 December 2007 Page 10 USER NOTES...

Страница 11: ...XDB300 0 0 GB 04 December 2007 Page 11 USER NOTES...

Страница 12: ...cable to the ImproX DBv Vertical Mount Drop Box XDB902 1 0 GB 02 and XDB903 1 0 GB 01 The last two digits of the Impro stock code indicate the issue status of the product XDB300 0 0 GB 04 Issue 05 Dec...

Отзывы: