Basic functionality
READINg ThE FlOOR TEmPERATuRE
With the thermostat turned on.
Press “
m
” once, the “
FT
” will flash, and the display will show
the floor temperature.
In program mode 2 (floor sensor) the display always shows the current
floor temperature.
In program mode 1 and 4 (room sensor) the display always shows the
current room temperature.
FROST PROTEcTION mODE
To enable frost protection mode.
With the thermostat turned off.
Press “
M
” for 3 seconds.
Select 01 (00 = disabled)
When enabled and the thermostat has been turned off, the heating
will be activated if the room/floor temperature is lower than 5° C; the
heating will turn off if the room/floor temperature is higher than 7° C.
When frost protection mode has been enabled the display shows “
”.
ERROR cODES
E1: Error on the room sensor (contact installer)
E2: Error on the floor sensor (contact installer)
(only in mode 3 and 5)