background image

10

AcTIvATE TImER mODE

When using the timer mode, you must first activate the timer mode:

With the thermostat turned on, hold the “

M

” button for 3 seconds. 

You can select below settings: 

00 = Override (disable timer functionality) 
01 = Programmable. And the display will show “

”. 

Leave the thermostat and it will go back to normal display.

PROgRAmmINg ThE TImER - mODE 01

When programming you need to select Programmable function and 
the display must show “

” (see above)

You can now set the heating programs. The thermostat must have 
4 heating periods for the weekdays and 4 heating periods for the 
weekend. 

Please  notice  that  the  programming  of  the  whole  calendar  week 

must take place in one continuous process

, so it is a good idea to 

have  the  periods  written  down  for  reference  when  programming 
the thermostat.

Note, for the weekend you will also need to program 2 periods. You 
can choose one of the periods to be very short or in extension of 
the other.

Timer functionality

Содержание Amstat

Страница 1: ...Amstat Digital Timer Thermostat Installation guide...

Страница 2: ...6 Select how to control your floor heating system 6 Recommended settings 7 Setting the clock 8 Setting the floor temperature max limit 8 Reading the floor temperature 9 Frost protection mode 9 Error c...

Страница 3: ...perature the room temperature or combined Please follow the instructions in this manual to ensure many years of trouble free usage When installing the thermostat DO NOT apply direct pressure to the th...

Страница 4: ...and display description Current room temperature Heating element warming Day of the week Thermostat on On off Down Up Clock Mode Current floor temperature Timer mode activated Frost protection mode a...

Страница 5: ...properly sized screws into the wall socket wall box When installing the thermostat DO NOT apply direct pressure to the thermostat display When properly fastened and cables connected see diagram below...

Страница 6: ...ent turns on off around a room temperature setpoint the temperature shown in the display is the actual room temperature Combined floor and room temperature program modes 3 5 The heating element turns...

Страница 7: ...m sensor If total effect 0W 1840W x 2 floor sensor If total effect 0W 2990W x x 3 combined floor and room sensor If total effect 1840W 2990W x x 4 room sensor If total effect 1840W 2990W x 5 combined...

Страница 8: ...ction is used for wooden floors mainly and is only available in program modes using the floor sensor program mode 3 and 5 The temperature setting should be maximum 35C which is also the default set po...

Страница 9: ...erature Frost protection mode To enable frost protection mode With the thermostat turned off Press M for 3 seconds Select 01 00 disabled When enabled and the thermostat has been turned off the heating...

Страница 10: ...need to select Programmable function and the display must show see above You can now set the heating programs The thermostat must have 4 heating periods for the weekdays and 4 heating periods for the...

Страница 11: ...erature setting 18 C Example weekend Period 1 starting at 09 00 Temperature setting 22 C Period 2 starting at 23 00 Temperature setting 18 C Period 3 starting at 23 01 Temperature setting 22 C Period...

Страница 12: ...4 for the weekday you are now able to set the switching times for weekend Sa Su will be displayed Use Up Down key to set the required start time Press to accept this setting Use the Up Down key to set...

Страница 13: ...13 Notes...

Страница 14: ...11 2 kOhm Display LCD Power consumption 2W Set point range Room 5 C to 35 C Floor 20 C to 35 45 C Accuracy 1 C Buttons Touch pad Switch current rating 13A resistive load Mains voltage 85 240V Dimensi...

Страница 15: ...ectrician installer Thermostat name Installation date Article number Stamp Stamp Please notice In order to obtain the this warranty an authorized electrician installer must fill in the below fields Na...

Страница 16: ...VIIID102 20131114 IMPEY SHOWERS LIMITED CONQUEST BUSINESS PARK ILTON SOMERSET TA19 9EA TEL 0845 304 8727 FAX 01460 57605 EMAIL info impeyshowers com...

Отзывы: