The Disable Polling check box turns polling commands on or off for frame time, exposure
time, frame rate, and so on. You can change the polling time in milliseconds by entering a
number in the Polling Time field.
The software displays error messages when the camera returns a command error. You
can disable error checking by selecting the Disable Error Checking check box.
Download Terminal
The Download Terminal lets you upgrade the camera’s firmware and upload any
custom
files ― BPM, Flat Field Correction (FFC), Lookup Tables (LUT), or Register Set (RGS).
Figure 19: Download Terminal.
To download files to the camera:
1.
Click
File Type
and select a file type such as BPM, or LUT1/LUT2.
2.
Enter or browse to the location of the file on your computer.
3.
Select the file you want to download.
4.
Click
Load File
.
5.
Reboot the camera and restart the GUI for the changes to take into effect.
Connection
Use the Connection menu to switch ports and change baud rates.
Figure 20: Connections lets you control ports and baud rates.