WARNING:  

To reduce the risk of fire, electrical shock 

hazard, or injury to persons, observe the following: 
 
1  Shut off and disconnect all power supply to unit (s) 

prior to installation or service/repair of device. 

2  Use this unit only in manner intended by             

manufacturer. 

3  All applications of device must follow all applicable 

laws, codes, regulations and standards. 

4  Installation of device must be completed by a certified 

installation expert or HVAC professional. 

5  For residential use only, any use beyond factory      

recommendations voids all  warranties. 

Содержание MA7

Страница 1: ...Residential Make Up Air System MA7 MA8 MA10 Installation Instructions Warranty Information 425 Apollo Street Brea CA 92821 www imperialhoods com 800 851 4192 DO NOT THROW AWAY PROPERTY OF THE HOME OWNER ...

Страница 2: ... 1 Shut off and disconnect all power supply to unit s prior to installation or service repair of device 2 Use this unit only in manner intended by manufacturer 3 All applications of device must follow all applicable laws codes regulations and standards 4 Installation of device must be completed by a certified installation expert or HVAC professional 5 For residential use only any use beyond factor...

Страница 3: ...ust fan motor If you are unable to install in a straight duct run a 90 degree elbow may be required Low voltage wiring A from motorized fresh air damper is connected directly to the 24V power transformer Low voltage wiring B from motorized fresh air damper is connected to Switch Assembly Wire is connected from Switch Assembly to 24V Power Transformer Paddle is 3 4 L x 1 1 4 W and activates at the ...

Страница 4: ...de of the home Outside fresh air inlet must be installed on the exterior of the house a minimum distance of 10 ft from com bustion vents and other exhaust openings Locate the fresh air inlet away from any outside motor genera tor pump BBQ grill hearth fire pit chemical storage area or any poten tially hazardous exposure areas ...

Страница 5: ...urn air duct The outside air will then pass through the furnace filter prior to being distributed throughout the air supply system When air is no longer being exhausted by the kitchen range hood the Switch Assembly will return to the off position The installation method will override or affect the normal function of the HVAC thermostat or corresponding components The HVAC system will heat and cool...

Страница 6: ...e United States will not be covered under manufacturer s limited warranty Additional Items Excluded From Manufacturer s Limited Warranty Cosmetic damages not reported or claimed within 48 hours of original purchase Damage or failure resulting from accident fire flood Acts of God improper installation or installation not in accordance to applicable laws codes and regulations Any alteration or modif...