Imperial Kitchen Ventilation 1930ENV Скачать руководство пользователя страница 3

Economy Series Installation Details:  

 

MODELS 

1900E, 1900ENV 

 

CABINET: 

Be sure that the cabinet bottom is level, side to side and front to rear.  

For the Vented Unit (1900E) you will need to cut an  8” x  8” hole in the bottom of the cabi-
net, 3/4” in from the rear wall and on center line.  For the Non-Vented model (1900ENV) 
there is no need for a duct pipe cut out.  Shelves and top to be cut to clear 7” round pipe to 
line up with the bottom cabinet cut out.  Also, cut holes for electrical wires for both Vented 
and Non-Vented.   
 

ELECTRICAL: 

Bring enough wire into cabinet to reach in front of vent pipe.  Enter cabinet  

3 1/4” left of center and 1 1/2” from wall for vented and non-vented units.  Remove  
electrical  box cover before mounting hood.  

Units are to be hard wired.  It is not        

recommended to add a power-cord.  Adding a power cord can loosen existing wires 
inside junction box causing electrical failure. 

 

NOTE: 

Be sure to remove black electrical tape that holds the damper blades closed. 

 

MOUNTING:  

Insert canopy below the cabinet, being sure your vent opening and electrical 

cut outs line up with cabinet cut outs.  Use the Key Hole mounting holes to secure the  
canopy.  After hood is mounted attach house wires to leads in the hood.  Secure locknut to 
conduit and check wiring for compliance to local building codes. 
 

FINISH: 

Replace electrical box cover.  Connect duct and tape all joints. Install 40 Watt bulb 

and replace Filter. (bulbs not included) 
 

WARNING: 

To reduce the risk of fire or electrical shock DO NOT use the “E” series with any solid-state 
speed control device. 

1900ENV 

1900E 

Содержание 1930ENV

Страница 1: ...Instructions Warranty Information 425 Apollo Street Brea CA 92821 www imperialhoods com 800 851 4192 DO NOT THROW AWAY PROPERTY OF THE HOME OWNER ECON 5 26 20 Unit is to be hardwired Adding a Power C...

Страница 2: ...d the warranty DO NOT use flex ducting Also use either a Roof Cap or Wall Cap to end run Be sure that all joints are taped securely in place It is essential to have the proper distance between the bot...

Страница 3: ...e electrical box cover before mounting hood Units are to be hard wired It is not recommended to add a power cord Adding a power cord can loosen existing wires inside junction box causing electrical fa...

Страница 4: ...we will need the exact dimensions of the filter needed Indicate which side has the pull tabs on it Filters are not a warranty replacement part With care your filters should last many years Payment on...

Страница 5: ...cation during the scheduled date and time and no one is home you will be charged a trip charge by the service company for a return service call 1900E or 1900ENV we will provide parts only for 1 year f...

Страница 6: ...ie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT NEVER PICK UP A FLAMING PAN you may be badly burne...

Страница 7: ...1900E 1900ENV Instructions d installation Informations sur la garantie 425 Rue Apollo Brea CA 92821 www imperialhoods com 800 851 4192 PROPRI T DU PROPRI TAIRE DE LA MAISON NE PAS JETER...

Страница 8: ...urner aussi court et aussi droit que possible vitez d utiliser des coudes si possible Si les coudes sont utilis s nous recommandons que le premier coude est 24 d ouverture sur le capot minimum de 12 p...

Страница 9: ...ventil es et non ventil Enlever le couvercle de bo te de jonction avant hotte de montage Remarque N oubliez pas de retirer le ruban isolant noir qui maintient les lames clapet ferm s De montage Insert...

Страница 10: ...de filtres nous devrons les dimensions exactes du filtre n cessaire Indiquer de quel c t a les tirettes sur elle Les filtres ne sont pas une pi ce de rechange de garantie Avec soin vos filtres doivent...

Страница 11: ...e service arrive votre emplacement au cours de la date pr vue et l heure et personne n est la maison vous serez factur frais de transport par la soci t de service pour une visite de retour de service...

Страница 12: ...uffez les flammes avec un couvercle herm tique une t le biscuits ou un plateau m tallique puis teignez le br leur VEILLEZ VITER LES BR LURES Si les flammes ne vont pas sortir imm diatement vacuer et a...

Страница 13: ......

Страница 14: ...________________ MODEL __________________________________________________________ SERIAL ___________________________________________________________ Serial beneath filters on white label Warranty card...

Отзывы: